Lutron Installation Guide: Wireless Smart Panel, 10 Output (35V) (045538, rev C)

Lutron's installation guide for the QSPSY-10PNL Smart Panel, which powers Sivoia QS Wireless drives from 35 V DC outputs.

About document 045538

Lutron document 045538, Rev C of February 2017, is the Sivoia QS Wireless Smart Panel installation guide: ratings, enclosure opening, surface or recess mounting, line-voltage input, output wiring, link length table and status LEDs.

What guide 045538 covers

Lutron document 045538 has these nine sections, all on page 1.

  1. Important notes: ratings, breaker size and environment
  2. Prepare the Smart Panel
  3. Mount the Smart Panel: surface or recess
  4. Connect line voltage
  5. Connect Sivoia QS Wireless window treatments
  6. Rules for output wiring and link length table
  7. Monitor output status
  8. Warnings: electric shock and fire
  9. FCC and IC compliance statements

Specifications in 045538

Lutron document 045538 prints 34 values in the groups the document uses, each with the document's unit. A row names the catalog codes it applies to. The page link beside each group opens the PDF where the group starts.

Input
120 V~ to 240 V~, 50/60 Hz, 10 AModels: QSPSY-10PNL
Per output
35 V DC, 143 mA, 5 WModels: QSPSY-10PNL
Maximum feed circuit breaker
20 AModels: QSPSY-10PNL
Ambient operating temperature
32 °F to 104 °F (0 °C to 40 °C)Models: QSPSY-10PNL
Humidity
0 to 90%, non-condensingModels: QSPSY-10PNL
Location
Indoor use onlyModels: QSPSY-10PNL
Phase-to-phase installation
Not intendedModels: QSPSY-10PNL
Installer
Qualified electricianModels: QSPSY-10PNL
Front cover screws
4, loosened
Line voltage shield screws
2, removed and refitted
Surface mount
3 keyholes in the back of the enclosure
Fastener rating
50 lb (23 kg) load
Recess mount
Right stud and a horizontal bottom support board between studs
Mounting hardware
Not provided
Power wire
10 AWG to 14 AWG (4.0 mm² to 2.5 mm²)
Strip length
5/16 in (8 mm)
Terminal torque
5 in-lb (0.5 N·m)
Conductors
Line, Neutral, Ground

Connect Sivoia QS Wireless window treatments

PDF page 1 of 045538, opens in a new tab
Strip length
1/4 in (6 mm)
Terminal torque
5 in-lb (0.5 N·m)
Output terminal blocks
2-pin, COM and V+; 10 provided, packaged separately
Strain relief devices
Not included
Output wiring class
NEC Class 2 / PELV
V+ between outputs
Never connected
Up to 8 Power Draw Units: maximum link wiring
2000 ft (610 m) on 12 AWG (4.0 mm²); 1000 ft (305 m) on 16 AWG (1.5 mm²); 600 ft (183 m) on 18 AWG (1.0 mm²)
1 Sivoia QS Wireless shade or drapery drive: maximum link wiring
500 ft (152 m) on 12 AWG (4.0 mm²); 200 ft (61 m) on 16 AWG (1.5 mm²); 125 ft (38 m) on 18 AWG (1.0 mm²)
2 roller 64, 30 sq ft (2.75 sq m) or less each: maximum link wiring
200 ft (61 m) on 12 AWG (4.0 mm²); 75 ft (23 m) on 16 AWG (1.5 mm²); 50 ft (15 m) on 18 AWG (1.0 mm²)
3 roller 64, 20 sq ft (1.8 sq m) or less each: maximum link wiring
200 ft (61 m) on 12 AWG (4.0 mm²); 75 ft (23 m) on 16 AWG (1.5 mm²); 50 ft (15 m) on 18 AWG (1.0 mm²)
2 roller 100, 50 sq ft (4.6 sq m) or less each: maximum link wiring
200 ft (61 m) on 12 AWG (4.0 mm²); 75 ft (23 m) on 16 AWG (1.5 mm²); 50 ft (15 m) on 18 AWG (1.0 mm²)
Status LED on
Output and connected devices operating normally
Status LED off
Short circuit; with no short, failed power supply module to replace
FCC
Part 15, Class B digital device
IC
Class B digital apparatus, ICES-003 / NMB-003
Figures printed on the drawing (not labeled)
1.69 in (43 mm); 6.00 in (152 mm); 4.69 in (119 mm); 0.80 in (20 mm); 1.45 in (37 mm)

Installation walk-through for 045538

Lutron document 045538 gives five steps, in the document's order, after the fixings it lists.

The clearance, the check and the warning under a step are the document's own.

Fixings

  • Fasteners for the surface, rated 50 lb (23 kg), not provided
  • Horizontal board between the studs as bottom support, recess mount
  • Strain relief devices, one for each knockout used (not included)
  • 10 AWG to 14 AWG (4.0 mm² to 2.5 mm²) power wire
  • 2-pin terminal blocks for the outputs (10 provided, packaged separately)
  1. Prepare the Smart Panel

    Loosen the four front cover screws, slide the cover upward and lift it away. Take out the two line voltage shield screws and lift the shield out, keeping the screws for refitting.

  2. Mount the Smart Panel

    Pick a place that will remain accessible, since Lutron supplies no mounting hardware. For a surface mount, fix the enclosure to the wall through the three keyholes in its back.

    For a recess mount, fit a horizontal board between the studs as a bottom support. Fix the panel to the right-hand stud and to that board through the holes provided.

    Check: Fasteners suit the surface and are rated for a 50 lb (23 kg) load

  3. Connect line voltage

    Knock out a tab near the input terminal blocks and fit a strain relief. Pull 10 AWG to 14 AWG (4.0 mm² to 2.5 mm²) power wire to the input blocks at the top left.

    Strip each conductor, land line, neutral and ground as the figure shows, and tighten each screw. Tighten the strain relief, then refit the line voltage shield with its original screws.

    Clearance: Strip 5/16 in (8 mm); torque 5 in-lb (0.5 N·m)

    Check: No insulation inside the terminal block

    Warning: Risk of electric shock: lock the supply circuit breaker off before wiring the terminal block

  4. Connect the Sivoia QS Wireless window treatments

    Remove knockout tabs on the left side as needed and fit a strain relief in each one used. Run the power cable from each Sivoia QS Wireless device through it.

    Strip each conductor, put COM and V+ into a 2-pin block as the receptacle labels show, and tighten the screws. Plug the block into a power output receptacle and tighten the strain relief.

    Lutron recommends making the final connection at the device after the panel work.

    Clearance: Strip 1/4 in (6 mm); torque 5 in-lb (0.5 N·m); run length within the output wiring table

    Check: Shade limits and free operation validated straight after power-up

    Warning: Risk of electric shock and fire: never interconnect power output terminals or join V+ between outputs

  5. Monitor output status

    Read the status LED fitted to each power output. A lit LED shows the output and its devices running normally.

    A dark LED points to a short circuit. With no short on the output, the power supply module has failed and needs replacing.

    Check: Every output in use shows its LED lit

Other warnings Lutron prints in 045538
  • Qualified electrician only, wiring and circuit protection to electrical codes
  • Some installations need a readily accessible disconnect device outside the panel
  • Electric shock risk: never energize the panel without the line voltage shield
  • Every line-voltage connection sits behind the shield
  • Output wiring is NEC Class 2 / PELV
  • Follow local and national codes for circuit separation and protection
  • Indoor use only, and not intended for phase-to-phase installations

Requirements Lutron states in 045538

What the guide requires for a Lutron shade before and during installation:

Input
  • 120 V~ to 240 V~, 50/60 Hz, 10 A
  • Maximum feed circuit breaker 20 A
  • Not for phase-to-phase installations
Per output
35 V DC, 143 mA, 5 W, on a plug-in 2-pin terminal block (10 blocks supplied)
Ambient operating temperature
32 °F to 104 °F (0 °C to 40 °C), 0 to 90% humidity non-condensing, indoor use only
Front cover
Held by 4 screws, loosened so the cover slides up and lifts off
Line voltage shield
Held by 2 screws, refitted after wiring
Mounting
  • Surface mount: 3 keyholes, fasteners rated for 50 lb (23 kg)
  • Recess mount: between studs on a horizontal board
  • Mounting hardware not provided, location must stay accessible
Line-voltage wiring
  • 10 AWG to 14 AWG (4.0 mm² to 2.5 mm²) power wire through a strain relief
  • Strip length 5/16 in (8 mm)
  • Terminal screws to 5 in-lb (0.5 N·m)
Output wiring
  • NEC Class 2 / PELV
  • Strip 1/4 in (6 mm)
  • COM and V+ into a 2-pin block at 5 in-lb (0.5 N·m)
  • V+ terminals never connected between outputs
Maximum devices per output
  • Up to 8 Power Draw Units
  • One Sivoia QS Wireless shade or drapery drive
  • Two roller 64 shades at 30 sq ft (2.75 sq m) or less each
  • Three roller 64 shades at 20 sq ft (1.8 sq m) or less each
  • Two roller 100 shades at 50 sq ft (4.6 sq m) or less each
Link length, 8 PDU
  • 2000 ft (610 m) on 12 AWG (4.0 mm²)
  • 1000 ft (305 m) on 16 AWG (1.5 mm²)
  • 600 ft (183 m) on 18 AWG (1.0 mm²)
Link length, one drive
  • 500 ft (152 m) on 12 AWG (4.0 mm²)
  • 200 ft (61 m) on 16 AWG (1.5 mm²)
  • 125 ft (38 m) on 18 AWG (1.0 mm²)
Link length, shared output
Two or three roller 64 or two roller 100 shades on one output:
  • 200 ft (61 m) on 12 AWG (4.0 mm²)
  • 75 ft (23 m) on 16 AWG (1.5 mm²)
  • 50 ft (15 m) on 18 AWG (1.0 mm²)
Status LED
On means normal running, off means a short circuit or, with no short, a failed power supply module to replace
Regulatory
FCC part 15 Class B digital device, and Class B digital apparatus to Canadian ICES-003 (NMB-003)

Questions about document 045538

The answers come from Lutron document 045538 and New Way's record of it.

What is Lutron document 045538?

Lutron's two-page Smart Panel installation guide, dated February 2017, printing revision C in its header and six further languages.

Which revision of 045538 is current?

Rev C, dated February 2017, is the revision Lutron publishes. New Way checked it against assets.lutron.com on 15 October 2026.

How many shades can one QSPSY-10PNL output power?

Up to 8 Power Draw Units, or one Sivoia QS Wireless shade or drapery drive, per Lutron document 045538.

  • Two roller 64 shades of 30 sq ft (2.75 sq m) or less
  • Three roller 64 shades of 20 sq ft (1.8 sq m) or less
  • Two roller 100 shades of 50 sq ft (4.6 sq m) or less

What supply does the Smart Panel need?

A 120 V~ to 240 V~, 50/60 Hz, 10 A input, wired by a qualified electrician, per Lutron document 045538.

  • Maximum feed circuit breaker: 20 A
  • Power wire: 10 AWG to 14 AWG (4.0 mm² to 2.5 mm²)
  • No phase-to-phase use, an external disconnect where required

How far can the output wiring run from the panel?

Up to 500 ft (152 m) on 12 AWG (4.0 mm²) for one drive per output, per Lutron document 045538.

  • 16 AWG (1.5 mm²): 200 ft (61 m)
  • 18 AWG (1.0 mm²): 125 ft (38 m)
  • Up to 8 PDU: 2000 ft (610 m), 1000 ft (305 m), 600 ft (183 m)

What strip lengths and terminal torque does the panel use?

Strip 5/16 in (8 mm) on the line-voltage conductors and 1/4 in (6 mm) on the outputs, per Lutron document 045538.

Lutron document 045538 tightens every terminal screw to 5 in-lb (0.5 N·m) with no insulation inside the block. The input wire enters through a strain relief that Lutron does not supply.

What does a dark status LED on an output mean?

Lutron document 045538 states that an LED that is off indicates a short circuit on that output. If the output has no short, Lutron document 045538 says the power supply module has failed and must be replaced.

Can the Smart Panel be recessed, and where can it go?

A recess mount between studs on a horizontal board, or a surface mount on three keyholes, per Lutron document 045538.

  • Surface fasteners rated for 50 lb (23 kg)
  • Indoors, at 32 °F to 104 °F (0 °C to 40 °C)
  • 0 to 90% non-condensing humidity, in a location that stays accessible
Ask about 045538

Documents used with 045538

For each device's Power Draw Units, Lutron document 045538 refers to 369405, the QS Link Power Draw Unit specification submittal. Lutron document 3672148 is the commercial roller shade selection guide for Sivoia QS shades.

Revisions of 045538

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
CFeb 2017Current. The file on assets.lutron.com. Checked 15 Oct 2026.

Not covered in 045538, and what to read next

Lutron document 045538 gives no Power Draw Unit value per device, no drawing dimension labels and no drive limit setting.

  • Device PDU values: 369405, the QS Link Power Draw Unit specification submittal
  • Limit setting: each Sivoia QS Wireless drive's own installation guide

Publisher and citation for document 045538

Lutron Electronics Co., Inc. publishes document 045538, Rev C, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 15 October 2026.

Lutron and Sivoia QS are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Lutron?

New Way supplies and installs Lutron shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.

The form opens with document 045538 filled in.