About this drawing
Lutron drawing 0251-KIRB-WMT-S, Rev A, is the one-page typical section, view 1 at scale 1/2: wall, wood blocking, cornice minimums, maximum roll-up, hembar, glazing and a legend placing views 1 and 2.
What this drawing covers
This drawing has these seven sections, all on its one page.
- Sheet heading and title block
- View 1, typical section at scale 1/2
- Wood blocking and cornice minimums
- Maximum roll-up diameter
- Hembar (varies) and glazing (typical)
- Five dimensions without a label, one marked approximate
- Legend placing view 1 and view 2
Specifications in this drawing
This drawing prints nine values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.
- Minimum cornice depth
- 8.00 in (203 mm)
- Minimum cornice height
- 12.00 in (305 mm)
- Max. rollup
- 3.00 in (76 mm) diameter
- horizontal dimension under the minimum cornice depth
- 5.58 in (142 mm)
- vertical dimension drawn on the wood blocking
- 7.56 in (192 mm)
- horizontal dimension, left of the section below the wood blocking
- 0.27 in (7 mm)
- horizontal dimension, lower right of the section
- 0.75 in (19 mm)
- dimension with leader, lower center of the section
- approx. 5.50 in (140 mm)
- Scale
- 1/2
Facts Lutron states in this drawing
The values this drawing states, as published:
- Drawing number
- 0251-KIRB-WMT-S in the box at the top right, with the title block's DRAWING # field left blank
- Revision
- A, printed in the title block
- Sheet title
- Drapery detail drawing, Kirbe drape with Roller 64, wall mount (the title block spells it Kirbé)
- View and scale
- View 1, typical section, scale 1/2
- Minimum cornice depth
- 8.00 in (203 mm)
- Minimum cornice height
- 12.00 in (305 mm)
- Maximum roll-up
- 3.00 in (76 mm) in diameter
- Dimensions without a label
- 5.58 in (142 mm), 7.56 in (192 mm), 0.27 in (7 mm), 0.75 in (19 mm) and approximately 5.50 in (140 mm)
- Labeled parts
- Wood blocking, hembar (varies) and glazing (typical)
- Legend
- A top view legend places view 1, this section, and view 2, the elevation
- File formats
- PDF (one page, about 136 KB), DWG and DXF
- Copyright year
- 2009 in the title block, with no issue date printed
Questions about this drawing
The answers come from this drawing and New Way's record of it.
What is this drawing?
Lutron's drapery detail section through a wall-mounted Kirbe drape with Roller 64, for sizing the cornice and blocking. Lutron drawing 0251-KIRB-WMT-S, Rev A, is the one-page typical section, view 1 at scale 1/2: wall, wood blocking, cornice minimums, maximum roll-up, hembar, glazing and a legend placing views 1 and 2.
Which revision of this drawing is current?
Rev A is the revision Lutron publishes. New Way checked it against assets.lutron.com on 16 October 2026.
What does Lutron drawing 0251-KIRB-WMT-S show?
Lutron drawing 0251-KIRB-WMT-S cuts through the wall and its wood blocking, the cornice, the roll and the glazing. The hembar is marked as varying and the glazing as typical; no issue date is printed.
What cornice size does Lutron give for the wall mount?
Lutron labels a minimum cornice depth of 8.00 in (203 mm) and a minimum cornice height of 12.00 in (305 mm) on the section.
How large does the roll get?
Lutron prints a maximum roll-up of 3.00 in (76 mm) in diameter on the section.
Where is the matching elevation?
Lutron's legend marks this section as view 1 and the elevation as view 2. The elevation is drawn on 0252-KIRB-WMT-F, the Kirbe drapery wall-mount elevation drawing.
Which documents go with this drawing?
Guide 045209: installation guide: Kirbe Drapery, Vertical Drapery Chassis goes with this drawing, listed under Documents used with this drawing.
Documents used with this drawing
Lutron drawing 0252-KIRB-WMT-F is view 2, the elevation paired with this section, and 0279-KIRB-WMB-V the Kirbe bracket detail. Lutron document 045209 is the Kirbe drapery vertical drapery chassis installation guide.
| Document | Type | Revision | Date |
|---|---|---|---|
| 045209Installation Guide: Kirbe Drapery, Vertical Drapery Chassis | Installation Guide | B | May 2015 |
Revisions of this drawing
This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.
| Revision | Date | Status |
|---|---|---|
| A | Not stated | Current. The file on assets.lutron.com. Checked 16 Oct 2026. |
Not covered in this drawing, and what to read next
Lutron drawing 0251-KIRB-WMT-S shows the section only: no drapery width, light gaps or cornice ordering rule.
- Elevation: 0252-KIRB-WMT-F, the Kirbe drapery wall-mount elevation drawing
- Mounting: 045209, the Kirbe drapery vertical drapery chassis installation guide
Publisher and citation for this drawing
Lutron Electronics Co., Inc. publishes this document and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 16 October 2026.
Lutron is a trademark of Lutron Electronics Co., Inc.
Reviewed by Edmond Hong, Technical Specialist, New Way.