About document 045450
Lutron document 045450, Rev A of March 2014, is the 2-inch vane horizontal sheer blind installation guide: tools and box contents, top back cover screws, hanging, terminal wiring, limits, leveling, fascia, control assignment and troubleshooting.
What guide 045450 covers
Lutron document 045450 has these twelve sections. Each link opens the PDF at that page in a new tab.
- Prepare to install: tools and box contents, opens in a new tab page 1
- Prepare the top back cover, opens in a new tab page 1
- Mount the top back cover, opens in a new tab page 1
- Installing an RF receiver (optional), opens in a new tab page 1
- Install end brackets on the blind, opens in a new tab page 1
- Hang the blind, opens in a new tab page 1
- Basic wiring, opens in a new tab page 1
- Set limits: upper, lower and privacy position, opens in a new tab page 2
- Adjust level and alignment, opens in a new tab page 2
- Attach the fabric-wrapped fascia, opens in a new tab page 2
- Assigning blinds to RF, wired and IR controls, opens in a new tab page 2
- Troubleshooting and restoring factory default settings, opens in a new tab page 2
Specifications in 045450
Lutron document 045450 prints 21 values in the groups the document uses, each with the document's unit. A row names the catalog codes it applies to. The page link beside each group opens the PDF where the group starts.
Prepare to Install
PDF page 1 of 045450, opens in a new tab- Drill bit
- 3/16 in (5 mm)
- Box contents
- Horizontal sheer blind (do not unroll), top back cover, end brackets, 4-pin terminal block, mounting screws (quantity varies with blind size), optional fabric-wrapped fascia with end caps
Prepare the Top Back Cover
PDF page 1 of 045450, opens in a new tab- Screw pair from each end of the cover
- 2 to 5 in (51 to 127 mm)
- Blinds wider than 48 in (1219 mm)
- Two additional screw pairs, approximately equally spaced
- Fixing surface
- Wall studs or solid trim; otherwise expansion anchors, toggle bolts or other fasteners, not included
Mount the Top Back Cover
PDF page 1 of 045450, opens in a new tab- Above-trim mount
- Spacer blocks, not included, thick enough for the blind to clear the trim
Basic Wiring
PDF page 1 of 045450, opens in a new tab- Outer jacket strip
- 2 in (51 mm)
- Wire insulation strip
- 1/4 in (6 mm)
- Exposed conductor at the terminal
- 1/16 in (2 mm)
- 4-pin terminal block
- Common, 24 V, MUX, MUX; terminals 3 and 4 for wired control and communication only
- Cable
- 4-conductor shown; number and colors of conductors may vary
Set Limits
PDF page 2 of 045450, opens in a new tab- Privacy position stored
- Green LED flashes for about 10 seconds, then turns off
Adjust Level and Alignment
PDF page 2 of 045450, opens in a new tab- Vertical adjustment per bracket
- ±1/4 in (6 mm)
Assigning Blind(s) to RF Controls
PDF page 2 of 045450, opens in a new tab- Assignment mode
- Green LEDs on blind and receiver flash twice, then every 4 seconds
- Completing assignment
- Hold the Bottom button on the wireless control for 6 seconds
Assigning Blind(s) to Wired and IR Controls
PDF page 2 of 045450, opens in a new tab- Programming mode
- Hold Open and Close together for 5 seconds to enter and to exit
Troubleshooting
PDF page 2 of 045450, opens in a new tab- Wireless range
- Within 30 ft (9.1 m) of the receiver
- Power check
- Unplug and re-plug the drive; the LED should flash for 5 seconds
- Maximum run-time
- Red LED blinks slowly four times, then off for 4 seconds; wait 20 minutes
- No communication
- Red LED on steady; check wiring
- Approved supply
- 24 V DC, such as the QSPS-P1-10-60Models: QSPS-P1-10-60
Installation walk-through for 045450
Lutron document 045450 gives twelve steps, in the document's order, after the tools and fixings it lists.
The clearance, the check and the warning under a step are the document's own.
Tools
- Tape measure
- Level
- Wire cutter/stripper
- Power drill
- 3/16 in (5 mm) drill bit
- #2 Phillips screwdriver
- Small flat-blade screwdriver
Fixings
- Mounting screws (provided; quantity varies with blind size)
- Expansion anchors or toggle bolts, not included, for other surfaces
- Spacer blocks for an above-trim mount (not included)
- 4-pin terminal block (provided)
Plan the top back cover
Hold the cover up centered on the window and pencil the screw positions. Place a screw pair 2 to 5 in (51 to 127 mm) in from each end, into wall studs or solid trim.
Blinds over 48 in (1219 mm) take two more pairs at roughly equal spacing.
Clearance: 2 to 5 in (51 to 127 mm) from each end
Check: The cover will sit level, centered on and parallel to the opening
Pre-drill and mount the cover
Drill the cover at the marks and fasten it. An inside mount centers the cover in the opening.
On trim, set the cover's top edge at the point the window height was measured from.
Warning: An above-trim mount needs spacer blocks (not included) so the blind clears the trim
Fit the RF receiver (optional)
Mount the receiver per its own instructions, clear of the blind. Clip the antenna to hang below the bottom edge of the top back cover.
Fit the end brackets
Face the control buttons down and route the cables up through the notch. Push the drive end into the bracket's square receiver and tighten the bracket screw.
Fit the other end bracket, then loosen both front-hook retaining screws.
Check: Control buttons face downward
Hang the blind
Hook the end brackets onto the top back cover. Center the blind on the window and tighten the retaining screw on each front hook.
Wire the blind
Strip 2 in (51 mm) of jacket and 1/4 in (6 mm) per wire and land the wires on the 4-pin terminal block. Connect the blind EDU connector and any RF receiver connector.
Clearance: 1/16 in (2 mm) of bare conductor at the terminal
Check: Cables are secured clear of moving parts
Warning: Shock hazard: lock the supply breaker off or remove the fuse first
Check and set the limits
Check the factory limits straight after installation. To reset one, tap its limit button and drive the blind with the arrows.
For the lower limit, run down to the fully open View position. Hold the limit button until the green LED flashes; setting the lower limit also teaches the drive the Privacy position.
Check: Fully raised and fully lowered positions match the opening
Warning: If the bottom bar meets the sill before the vanes open fully, raise the bracket and reset the lower limit
Adjust the Privacy position (optional)
Tap the arrows to the wanted Privacy position. Hold Lower Limit until the green LED flashes.
Hold it a second time until the LED flashes for about 10 seconds and goes out.
Level and align (optional)
Raise the blind fully for access, then turn each bracket's vertical screw counterclockwise to raise or clockwise to lower. Match adjacent blinds so their vanes line up.
Clearance: ±1/4 in (6 mm) per bracket
Fit the fascia (optional)
Press an end cap onto each end of the fascia, tabs in its channels. Hang the fascia on the end brackets' top front hooks and press its lower half onto the bottom hooks.
Warning: On inside mounts the drive-side end cap may need notching for the wiring
Assign wireless controls
On each blind, hold Upper Limit until the green LED stays on and tap the button on the drive. Then hold the control's Bottom button for 6 seconds until the blinds wiggle once.
Check: Each blind wiggles once
Assign wired and IR controls
Hold Open and Close for 5 seconds to enter programming mode. Tap Open to pick a blind and Lower to assign it.
Hold Open and Close for 5 seconds again to exit.
Check: The assigned blind moves to its lower limit
Requirements Lutron states in 045450
What the guide requires for a Sivoia QS shade before and during installation:
- Tools
- Tape measure, level, wire cutter and stripper, power drill with a 3/16 in (5 mm) bit, #2 Phillips screwdriver, small flat-blade screwdriver
- In the box
- Horizontal sheer blind (do not unroll)
- Top back cover
- 4-pin terminal block
- Mounting screws (quantity varies with blind size)
- Optional fabric-wrapped fascia with end caps
- Local and national electrical codes
- Clearance between the moving blind and window hardware, cranks, levers, drapery
- Top back cover screws
- Screw pair 2 to 5 in (51 to 127 mm) in from each end
- Into wall studs or solid trim
- Blinds wider than 48 in (1219 mm): two more pairs at equal spacing
- Other surfaces: expansion anchors or toggle bolts (not included)
- Above-trim mounts: spacer blocks (not included)
- Hanging the blind
- Drive end in with the control buttons facing down and the cables routed up through the notch. End brackets hang on the hooks of the top back cover, then each front hook's retaining screw is tightened.
- RF receiver (optional)
- Mounted per its own instructions where it will not obstruct the blind. The antenna hangs below the top back cover's bottom edge, and the receiver plugs into the blind's RF connector.
- Wiring
- Strip 2 in (51 mm) of jacket and 1/4 in (6 mm) of insulation
- Leave 1/16 in (2 mm) of bare conductor at the 4-pin terminal block
- Terminals: Common, 24 V, MUX and MUX
- Terminals 3 and 4 serve wired control only
- Lock the supply breaker off before wiring
- Lower limit positions
- Privacy position (vanes closed) and View position (vanes fully open, the lower limit) at the bottom of travel. The drive learns the Privacy position when the lower limit is set, and Privacy can be adjusted separately.
- Level adjustment
- Each bracket's vertical screw raises or lowers the blind by 1/4 in (6 mm) for leveling and vane alignment with adjacent blinds
- Fabric-wrapped fascia (optional)
- End caps press onto each end. The fascia hangs on the end brackets' top front hooks and presses in at the bottom.
- Fascia end cap notch
- On inside mounts the drive-side end cap may need notching for wiring
- Troubleshooting signals
- Red LED blinking slowly four times: maximum run-time reached, wait 20 minutes
- Steady red: no communication, check wiring
- Fast blue: too little power or an AC supply
- Use an approved 24 V DC supply such as the QSPS-P1-10-60
- Factory reset
- Restoring factory defaults un-assigns the blind from all wireless controls but leaves the open and lower limits as they are
Questions about document 045450
The answers come from Lutron document 045450 and New Way's record of it.
What is Lutron document 045450?
Lutron's two-page guide, printed 03/2014 under P/N 045450 Rev A, for a motorized blind hung on a top back cover. The blind takes a 24 V DC supply through a 4-pin terminal block, with an optional RF receiver.
Lutron sets the limits at the factory from the window measurements.
Which revision of 045450 is current?
Rev A, dated March 2014, is the revision Lutron publishes. New Way checked it against assets.lutron.com on 15 October 2026.
Which horizontal sheer blinds does 045450 cover?
Lutron Sivoia QS horizontal sheer blinds.
What does the guide require of the power supply and controls?
Lutron hardware, controls and power supplies only, per Lutron document 045450, installed to local and national electrical codes. The troubleshooting table names an approved 24 V DC supply such as the QSPS-P1-10-60.
A fast-blinking blue LED means an AC supply or too little power.
What clearance does the blind need around the window?
Room between the moving blind and anything near it, per Lutron document 045450: window hardware, cranks, lock levers, drapery. An above-trim mount uses spacer blocks (not included) thick enough for the blind to clear the trim.
Where do the top back cover screws go?
Lutron document 045450: a screw pair 2 to 5 in (51 to 127 mm) in from each cover end, into studs or solid trim.
- Blinds wider than 48 in (1219 mm): two more pairs at roughly equal spacing
- Cover level, centered on and parallel to the window opening
How is the 4-pin terminal block wired?
Lutron document 045450 wires the 4-pin block to Common, 24 V, MUX and MUX.
- Strip 2 in (51 mm) of outer jacket and 1/4 in (6 mm) of insulation
- Leave 1/16 in (2 mm) of bare conductor
- Terminals 3 and 4: wired control only, unused on wireless installations
What are the Privacy and View positions?
Lutron document 045450 defines Privacy as fully down with vanes closed and View as fully down with vanes fully open. View is the lower limit; setting it teaches the drive the Privacy position automatically.
A separate step adjusts Privacy without moving View.
Other Sivoia QS installation guides
Installation guides for the same Sivoia QS system:
| Document | Drive class | Revision | Date |
|---|---|---|---|
| 045415Horizontal Sheer Blinds Installation Guide | B | Mar 2014 | |
| 045520Basic Wiring and Setup Installation Guide | Roller 20 to 300 | B | Nov 2016 |
Documents used with 045450
Lutron document 045415 is the other Sivoia QS horizontal sheer blind installation guide. Lutron document 085313 is the blind's specification submittal and 3672457 its product brochure.
| Document | Type | Revision | Date |
|---|---|---|---|
| 085313Horizontal Sheer Blinds Specification Submittal | Specification Submittal | D | May 2016 |
| 3672457Horizontal Sheer Blinds Product Brochure: Sell Sheet | Product Brochure | C | Apr 2014 |
| 048846Application Note: EU EcoDesign Standby Power Information | Application Note | A | Nov 2024 |
| Performance Specification: Section 122113, Venetian Blinds | Performance Specification | ||
| 369612Pico Wireless Control Specification Submittal | Specification Submittal | Q | Jun 2025 |
| Application Note: Blink Codes for Shades and Venetian Blinds | Application Note | ||
| 3671319Product Brochure: Residential Shading Solutions | Product Brochure | K | Feb 2023 |
Revisions of 045450
This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.
| Revision | Date | Status |
|---|---|---|
| A | Mar 2014 | Current. The file on assets.lutron.com. Checked 15 Oct 2026. |
Not covered in 045450, and what to read next
Lutron document 045450 leaves power supply wiring, keypad programming and RF receiver mounting to the sheets packed with those parts.
Publisher and citation for document 045450
Lutron Electronics Co., Inc. publishes document 045450, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 15 October 2026.
Lutron and Sivoia QS are trademarks of Lutron Electronics Co., Inc.
Reviewed by Edmond Hong, Technical Specialist, New Way.
Specifying Sivoia QS?
New Way supplies and installs Lutron Sivoia QS shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.
The form opens with document 045450 filled in.