Contact Us
Opens in a new tab

085751 · CAD Drawing · Rev A · English · PDF, DWG, DXF

Lutron Serena Honeycomb Shades CAD Drawing: Architectural Inside Mount, Elevation View (085751)

Lutron's CAD elevation of the architectural honeycomb shade inside a window opening, with its two light gaps dimensioned.

About document 085751

Lutron drawing 085751, revision A, is the one-sheet inside window elevation, view 2 at scale 1/1: order width, shade height and stack height labels, two light gap figures and the master technician's clearance note.

What drawing 085751 covers

Lutron document 085751 has these seven sections, all on its one page.

  1. Sheet header: architectural honeycomb shade, inside window elevation
  2. Elevation inside the window opening
  3. Inside mount order width
  4. Ordered shade height and stack height
  5. Minimum light gap and gap at fabric
  6. Clearance note for the master technician
  7. Title block: drawing number, scale, view and revision

Specifications in 085751

Lutron document 085751 prints 13 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.

Minimum light gap
0.13 in (3 mm), marked 2X
Light gap at fabric
0.19 in (5 mm), marked 2X
Inside mount order width
Labeled, no value printed
Ordered shade height
Labeled, no value printed
Stack height
Labeled, no value printed
Construction labeled
Wall and window opening
Sheet header
Architectural honeycomb shade, inside window elevation
Drawing number
085751
Scale
1/1
View
2
Revision
A
View title
Elevation view
Clearance note
Shade installed as the factory supplies it has the clearances it needs to operate; the master technician keeps them after installation

Facts Lutron states in 085751

The values Lutron document 085751 states, as published:

Subject
Architectural honeycomb shade, inside window elevation
View, scale and revision
View 2, elevation view, scale 1/1, revision A. No issue date printed
Mounting shown
Inside mount: the shade sits within the window opening in the wall
Minimum light gap
0.13 in (3 mm), marked 2X (two places)
Light gap at the fabric
0.19 in (5 mm), marked 2X (two places)
Labeled without values
Inside mount order width, ordered shade height and stack height
Clearance note
A shade installed as supplied by the factory has the clearances for proper operation. The master technician keeps them after installation
File formats
PDF of one page, with DWG and DXF files of the same drawing
Not on the sheet
Fixing positions, bracket details, the power option, the fabric and size limits are not stated in the document

Questions about document 085751

The answers come from Lutron document 085751 and New Way's record of it.

What is Lutron drawing 085751?

Lutron's one-page PDF with matching DWG and DXF files, naming the architectural honeycomb shade only, not Serena or Triathlon.

Which revision of 085751 is current?

Rev A is the revision Lutron publishes. New Way checked it against assets.lutron.com on 16 October 2026.

Which honeycomb shades does 085751 cover?

Lutron Triathlon honeycomb shades.

What light gaps does Lutron show for an inside-mounted architectural honeycomb shade?

Lutron drawing 085751 prints a minimum light gap of 0.13 in (3 mm) and a light gap at the fabric of 0.19 in (5 mm). Lutron marks each figure 2X, so each gap is dimensioned for two places.

Which dimensions does the elevation leave without a figure?

Lutron drawing 085751 labels the inside mount order width, the ordered shade height and the stack height without values. Lutron's sheet gives figures only for the two light gaps.

Who keeps the clearances right once the shade is installed?

Lutron drawing 085751 states that a shade installed as the factory supplies it has the clearances it needs. Lutron makes the master technician responsible for keeping those clearances after installation.

Will an inside-mounted honeycomb shade fill the opening edge to edge?

Lutron drawing 085751 dimensions light gaps rather than an edge-to-edge fit, so narrow gaps of light show inside the opening. The minimum light gap is 0.13 in (3 mm) and the gap at the fabric 0.19 in (5 mm).

Does the elevation show how much window the stack takes?

Lutron drawing 085751 labels the stack height on the elevation but prints no figure for it. The stack size is therefore not stated in the document.

Ask about 085751

Other Triathlon CAD drawings

CAD drawings for the same Triathlon system:

All 19 Triathlon CAD drawings

Documents used with 085751

Lutron's 085750 and 085752 are the inside mount and battery access views; 085756, 085753 and 085754 the wall mount views. Lutron document 045902 is the installation guide and 085745 the specification submittal for the Serena and architectural honeycomb shades.

Revisions of 085751

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
ANot statedCurrent. The file on assets.lutron.com. Checked 16 Oct 2026.

Not covered in 085751, and what to read next

Lutron drawing 085751 shows the elevation only, without fixing positions, bracket details, the power option or the stack size.

  • Section: 085750, the matching inside mount section view CAD drawing
  • Installation: 045902, the Serena and architectural honeycomb installation guide

Publisher and citation for document 085751

Lutron Electronics Co., Inc. publishes document 085751, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 16 October 2026.

Lutron, Triathlon and Serena are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Triathlon?

New Way supplies and installs Lutron Triathlon shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.

The form opens with document 085751 filled in.