Contact Us
Opens in a new tab

085554 · CAD Drawing · Rev A · English · PDF, DWG, DXF

Lutron Sivoia QS Drapery CAD Drawing: Single Wall-Mount Tandem Draw, Plan View (085554)

Lutron's plan view of the Sivoia QS drapery tandem track on wall brackets, with bracket positions and lengths.

About document 085554

Lutron drawing 085554, revision A, is the one-sheet tandem wall mount plan at 1/10 scale: minimum track and system widths, clearance, bracket positions and spacing, EDU and idler lengths and the installer note.

What drawing 085554 covers

Lutron document 085554 has these seven sections, all on its one page.

  1. Plan view of the tandem track, wall mount
  2. Minimum track and system widths
  3. Bracket positions from track ends and splice centers
  4. Bracket-to-bracket spacing
  5. EDU and idler lengths
  6. Minimum clearance and installer clearance note
  7. Title block: scale, plan view, revision

Specifications in 085554

Lutron document 085554 prints 15 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.

Minimum per track
24 in
Minimum system width
48 in
Minimum clearance
3.50 in (89 mm)
From end of track, printed twice
8.00 in (203 mm)
Bracket-to-bracket spacing
16 in to 24 in (407 mm to 610 mm)
From splice center, printed twice
6 in to 8 in (152 mm to 203 mm)
EDU length
3.63 in (93 mm)
Idler length
3.19 in (81 mm)
Unlabeled
2.38 in (60 mm)
Unlabeled
1.63 in (42 mm)
Sheet title
Drapery wall mount, tandem track
Drawing number
085554
Scale
1/10
View
Plan
Revision
A

Facts Lutron states in 085554

The values Lutron document 085554 states, as published:

Sheet title
Drapery wall mount, tandem track, plan view
Minimum per track
24 in
Minimum system width
48 in
Minimum clearance
3.50 in (89 mm)
End bracket position
8.00 in (203 mm) from the end of the track, printed twice
Bracket-to-bracket spacing
16 in to 24 in (407 mm to 610 mm)
Brackets at a splice
6 in to 8 in (152 mm to 203 mm) from the splice center, printed twice
EDU length
3.63 in (93 mm)
Idler length
3.19 in (81 mm)
Further plan dimensions
2.38 in (60 mm) and 1.63 in (42 mm), printed without labels
Scale and revision
1/10, plan view, revision A, no date on the sheet
Installer note
Tracks supplied by the factory and fitted to the drawing have the clearances for typical fabric panels. The installer keeps the clearances right for the panel actually chosen.

Questions about document 085554

The answers come from Lutron document 085554 and New Way's record of it.

What is Lutron document 085554?

Lutron's one-sheet plan view at 1/10 scale, revision A, undated, titled drapery wall mount, tandem track. Lutron drawing 085554 is a plan view only; 085808 is the wall mount all-views drawing of the same track.

Which revision of 085554 is current?

Rev A is the revision Lutron publishes. New Way checked it against assets.lutron.com on 16 October 2026.

Which drapery tracks does 085554 cover?

Lutron Sivoia QS drapery tracks.

How wide must a tandem Sivoia QS drapery system be?

Lutron drawing 085554 states a minimum of 24 in per track and 48 in for the tandem system width. Lutron prints both figures in inches only.

What clearance does the tandem track need?

Lutron drawing 085554 shows a minimum clearance of 3.50 in (89 mm). Lutron adds that factory-supplied tracks fitted to the drawing suit typical fabric panels.

The installer keeps the clearances right for the fabric chosen.

Where do the wall brackets go on a tandem track?

Lutron drawing 085554 places the wall brackets at three plan dimensions.

  • 8.00 in (203 mm) from the end of the track
  • 16 in to 24 in (407 mm to 610 mm) bracket to bracket
  • 6 in to 8 in (152 mm to 203 mm) from a splice center

What EDU length and idler length does the tandem plan print?

Lutron drawing 085554 gives an EDU length of 3.63 in (93 mm) and an idler length of 3.19 in (81 mm).

What do the 2.38 in and 1.63 in figures measure?

Lutron drawing 085554 prints 2.38 in (60 mm) and 1.63 in (42 mm) on the plan without labels. The sheet does not say what either one measures.

Ask about 085554

Other Sivoia QS CAD drawings

CAD drawings for the same Sivoia QS system:

All 33 Sivoia QS CAD drawings

Documents used with 085554

Lutron drawing 085554 pairs with 085808, the wall mount all-views drawing, and 085810, the bracket detail drawing. Lutron documents 045982 and 086123 are the Sivoia QS drapery installation guide and chassis specification submittal.

Revisions of 085554

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
ANot statedCurrent. The file on assets.lutron.com. Checked 16 Oct 2026.

Not covered in 085554, and what to read next

Lutron drawing 085554 shows the tandem track in plan only: no elevation, section, bracket detail or wiring is printed.

  • Brackets: 085810, the bracket detail drawing
  • Installation: 045982, the Sivoia QS drapery installation guide

Publisher and citation for document 085554

Lutron Electronics Co., Inc. publishes document 085554, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 16 October 2026.

Lutron and Sivoia QS are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Sivoia QS?

New Way supplies and installs Lutron Sivoia QS shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.

The form opens with document 085554 filled in.