You searched and this document matched it.
See all results045983 · Installation Guide · Rev A · Sep 2024 · English · PDF, 3 pages, 2.4 MB
Lutron Sivoia QS Recessed System for Drapery Installation Guide (045983, rev A)
Lutron's installation guide for the Recessed System for Lutron Drapery: the ceiling pocket, recessed endcaps and recess-mount brackets.
Lutron 045983 Rev A (September 2024), Sivoia QS Recessed System for Drapery Installation Guide. https://assets.lutron.com/a/documents/045983.pdf, via https://newwaykl.com/resources/lutron/drapery/sivoia-qs/lutron-sivoia-qs-recessed-system-for-drapery-installation-guide-045983/
About document 045983
Lutron document 045983, Rev A of September 2024, is the three-page recessed drapery installation guide: blocking, the drywall recess, pocket assembly, the slot-to-slot measurement, mud and paint, then the track fixed with Lutron's self-drilling screws.
What guide 045983 covers
Lutron document 045983 has these seven sections. Each link opens the PDF at that page in a new tab.
- Prepare to install: overview and important notes, opens in a new tab page 1
- Preparing the ceiling, opens in a new tab page 1
- Choose double or single layer drywall, opens in a new tab page 1
- Install the pocket and recessed endcaps, opens in a new tab page 2
- Measure the pocket width and order the track, opens in a new tab page 3
- Mud and paint the ceiling, opens in a new tab page 3
- Install the track, opens in a new tab page 3
Specifications in 045983
Lutron document 045983 prints 24 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.
Environmental
PDF page 1 of 045983, opens in a new tab- Ambient operating temperature
- 32 °F to 104 °F (0 °C to 40 °C)
- Humidity
- 0 to 90%, non-condensing; indoor use only
Ceiling recess
PDF pages 1 and 2 of 045983, opens in a new tab- Recess depth
- 1.25 in (32 mm)
- Double layer drywall
- Two layers of 5/8 in (16 mm)
- Single layer drywall
- Joist notched by 5/8 in (16 mm)
- Spacer thickness shown in figure 1
- 5/8 in (16 mm) or 1 1/4 in (32 mm), not provided by Lutron
Pocket fixing
PDF page 1 of 045983, opens in a new tab- Distance of first screw from each end
- 1 in (25 mm)
- Maximum screw spacing along the track
- 16 in (406 mm)
- Endcaps
- Drive and idler endcaps both screwed to blocking
- Piece length
- 8 ft (2.4 m), cut to length; several pieces butted for wider systems
- Straightness
- Within plus or minus 1/16 in (2 mm)
- Drywall perimeter option
- About 8 in (203 mm) wide, installed with the pocket
- Spacer option
- Spacer thickness equal to the final drywall thickness
- Track width to order
- Slot-to-slot distance plus 6 in (152 mm)
- Slot-to-slot width when the track is ordered but not yet on site for a dry fit
- Ordered track width minus 6 in (152 mm)
- Cut length of the metal pocket
- Ordered track width minus 8 in (203 mm)
- Gap around the idler
- 1/16 in (2 mm)
- Clearance on the drive side
- 3/8 in (10 mm), for belt tensioning
- Recess-mount bracket rotation
- 90 degrees in the upper channel, one bracket per mounting hole
- Allen key for the bracket set screws
- 3/32 in (2 mm), provided
- Optional pilot hole for the track screw
- 1/8 in (3 mm)
Drawing values
PDF pages 1, 2 and 3 of 045983, opens in a new tab- Detailed views of the recessed drive endcap, recessed pocket and recessed idler endcap (values not labeled)
- 5.2 in (132 mm) printed with each endcap name, 3.5 in (90 mm), 1 in (25 mm), 4.5 in (114 mm)
- Profile drawing beside the alternate view of the recessed mounting bracket (values not labeled)
- 1.4 in (36 mm), 1.1 in (27 mm), 1.2 in (29 mm), 1 in (26 mm)
- Tape measure slot view, printed value
- 3 in (76 mm)
Installation walk-through for 045983
Lutron document 045983 gives eight steps, in the document's order, after the tools and fixings it lists.
The clearance, the check and the warning under a step are the document's own.
Tools
- Laser or straight edge
- Lutron Installation Tool (recommended)
- 3/32 in (2 mm) Allen key (provided)
- Drill, low torque setting
- Compressed air or flexible pipe cleaner brush
- Painter's tape
Fixings
- Blocking for the drapery system in a wood, metal or concrete ceiling
- Pocket mounting screws, flanges into blocking, not provided by Lutron
- Self-drilling track mounting screws (provided by Lutron)
- Spacers equal to the final drywall thickness, not provided by Lutron
- Or a drywall perimeter about 8 in (203 mm) wide with the pocket
Prepare the ceiling
Add blocking to carry the weight of the drapery system, whatever the ceiling is built from. Plan the power wire to arrive at the drive end of the drapery.
The pocket will be screwed to this blocking 1 in (25 mm) from each end and at most every 16 in (406 mm). Both endcaps need blocking behind them too.
Clearance: Screws 1 in (25 mm) from the ends, no more than 16 in (406 mm) apart
Check: Blocking sits behind the full pocket length and behind both endcaps
Warning: Inspect the pocket and endcaps before installing; Lutron takes no responsibility for damage from a wrong installation
Choose double or single layer drywall
The pocket needs a recess 1.25 in (32 mm) deep so its flanges press tight to the board. Two layers of 5/8 in (16 mm) drywall give that depth.
With a single layer, notch the joist by 5/8 in (16 mm) instead, if the structure allows it.
Clearance: 1.25 in (32 mm) recess
Check: Any joist notching complies with the local building code and structural requirements
Warning: Follow every applicable building code when cutting into a ceiling joist
Mark the location of the drapery
Set the recessed drive endcap next to the 4-conductor cable, at the point where the drapery should end. With a laser or straight edge, mark where the idler endcap will sit.
Clearance: Pocket line straight within plus or minus 1/16 in (2 mm)
Check: Drive end and cable are on the same side
Assemble the pocket
Screw the drive endcap to the blocking, then cut the 8 ft (2.4 m) pocket pieces to length. Screw them through their flanges into the blocking.
Butt the pieces tightly and line them up so the Installation Tool slides across each joint without catching. Screw the idler endcap to the blocking, tight against the pocket.
Keep this work off the drywall trade with spacers at the finished board thickness, or a drywall perimeter about 8 in (203 mm) wide.
Clearance: Cut length 8 in (203 mm) less than the ordered track width. Slot-to-slot 6 in (152 mm) less than the track width when the track is ordered but not on site.
Check: Joints are tight, the Installation Tool runs smoothly end to end, and the idler endcap is hard against the pocket
Measure the pocket width and order the track
Measure between the tape measure slots, inside edge to inside edge. Order a track 6 in (152 mm) wider than that measurement.
Lutron's intended sequence is pocket first, then the track order. A track already on site can be dry-fitted before the pocket goes up.
Clearance: Track width = slot-to-slot distance + 6 in (152 mm)
Check: Slot-to-slot measured inside edge to inside edge before the track is ordered
Mud and paint the ceiling
Run painter's tape inside the pocket to keep it clean, then mud in the flanges and paint the ceiling.
Check: Pocket interior clean of mud and paint before the track arrives
Prepare the track
Slide a recess-mount bracket into the track's upper channel and line its center slot up with a mounting hole. A screw dropped through both holds the alignment.
Turn the bracket 90 degrees, tighten both set screws with the 3/32 in (2 mm) Allen key, and remove the alignment screw. Repeat at every mounting hole along the track.
Check: A bracket is locked at each mounting hole along the full track length
Mount the track
Center the idler end in its endcap with a 1/16 in (2 mm) gap all round. The drive side keeps extra room for belt tensioning.
Drive Lutron's self-drilling track screws with the tip on the pocket's center groove, on a low torque setting. A stripped screw gets a new hole beside it in the track.
Clear metal shavings out with compressed air or a pipe cleaner brush. Or drill a 1/8 in (3 mm) pilot hole first.
Clearance: 1/16 in (2 mm) gap around the idler; 3/8 in (10 mm) clearance on the drive side
Check: No metal shavings left inside the track
Count the screws securing the recessed pocket from 045983
Lutron document 045983 spaces the screws securing the recessed pocket: one at each end, at least 1 in (25 mm) in from the end. The rest sit at most 16 in (406 mm) apart.
Enter the track width to count the screws securing the recessed pocket.
From Lutron document 045983, page 1; confirm against the PDF before you drill.
Requirements Lutron states in 045983
What the guide requires for a Sivoia QS shade before and during installation:
- Recess depth
- 1.25 in (32 mm), so the pocket flanges press tight to the drywall
- Two layers of 5/8 in (16 mm) drywall give this
- Or a single layer with the joist notched by 5/8 in (16 mm)
- Pocket fixing
- Screwed to blocking 1 in (25 mm) from each end
- Screws no further apart than 16 in (406 mm) along the track
- Both drive and idler endcaps also screw to blocking
- Pocket screws not provided by Lutron
- Pocket lengths
- 8 ft (2.4 m) pieces, cut to length and butted tightly
- Several pieces joined for wider draperies
- Straight within plus or minus 1/16 in (2 mm) to receive the track
- Drive end location
- Recessed drive endcap beside the 4-conductor cable, where the drapery ends
- The power wire is routed at the drive end
- The idler endcap is marked with a laser or straight edge
- Ordering the track
- Measure slot to slot, inside edge to inside edge
- Order the track width equal to that distance plus 6 in (152 mm)
- Metal pocket cut length: 8 in (203 mm) less than the ordered track width
- Environment
- Ambient operating temperature 32 °F to 104 °F (0 °C to 40 °C)
- 0 to 90% non-condensing humidity
- Indoor use only
- Decoupling from drywall
- Spacer at final drywall thickness, so boards slide over the flanges
- Or fit a drywall perimeter about 8 in (203 mm) wide with the pocket
- Screw heads below the mud lip, countersunk if needed
- Installation tool
- Lutron recommends its Installation Tool to center and protect the track
- The tool serves as a drill guide for the track screws
- Slid across each butt joint, it aligns the pocket pieces
- Recess-mount brackets
- One bracket at each mounting hole along the track
- Rotated 90 degrees in the upper channel
- Locked with the 3/32 in (2 mm) Allen key provided
- Track fit in pocket
- 1/16 in (2 mm) gap around the idler end, 3/8 in (10 mm) clearance on the drive side for belt tensioning
- Track screws
- Self-drilling track mounting screws provided by Lutron
- Driven on a low torque setting into the pocket's center groove
- A stripped screw gets a fresh hole beside it
- A 1/8 in (3 mm) pilot hole is an option
- Clear metal shavings from inside the track
- Before mud and paint
- Painter's tape inside the pocket keeps it clean while the ceiling is mudded and painted
Questions about document 045983
The answers come from Lutron document 045983 and New Way's record of it.
What is Lutron document 045983?
Lutron's guide, P/N 045983 REV A dated 09/2024, for setting a drapery track flush in a drywall ceiling. The guide names no model numbers for the pocket parts.
Which revision of 045983 is current?
Rev A, dated September 2024, is the revision Lutron publishes. New Way checked it against assets.lutron.com on 15 October 2026.
Which drapery tracks does 045983 cover?
Lutron Sivoia QS drapery tracks.
How deep must the ceiling recess be?
Lutron document 045983 calls for a 1.25 in (32 mm) deep recess so the pocket flanges press tightly to the drywall.
- Two layers of 5/8 in (16 mm) drywall
- Or one layer with the joist notched by 5/8 in (16 mm)
- Joist work: the installer is responsible for code compliance
How do I size the track to the pocket?
Lutron document 045983 says to measure the slot-to-slot distance, inside edge to inside edge, and order the track 6 in (152 mm) wider.
- Track ordered, not yet on site: slot-to-slot 6 in (152 mm) under track width
- Metal pocket cut 8 in (203 mm) shorter than the ordered track width
How often is the pocket screwed to the ceiling?
Lutron document 045983 requires fixings 1 in (25 mm) from each end and no more than 16 in (406 mm) apart along the width. The screws go into blocking that carries the drapery weight, with both endcaps also screwed to blocking.
What clearance does the track need in the pocket?
Lutron document 045983 centers the idler in its endcap with a 1/16 in (2 mm) gap.
- Drive side: 3/8 in (10 mm) so the belt can be tensioned
- Pocket straight within plus or minus 1/16 in (2 mm)
Can the pocket go in before the track is ordered?
Yes, Lutron document 045983 describes that as the intended sequence: install the pocket, measure it, then order the track.
A track already on site can be dry-fitted to the pocket first. A track ordered but not yet delivered sets the slot-to-slot width at 6 in (152 mm) less than the ordered track width.
Other Sivoia QS installation guides
Installation guides for the same Sivoia QS system:
| Document | Drive class | Revision | Date |
|---|---|---|---|
| 045981Alena Drapery Installation Guide | A | Sep 2024 | |
| 045984Alena Drapery Installation Guide: QS RippleFold | A | Nov 2024 | |
| 045985Installation Guide: Wireless Drapery Lite System | A | Nov 2024 | |
| 045982Drapery Installation Guide | A | Sep 2024 |
Documents used with 045983
Lutron documents 045981 and 045984 are the Alena ripplefold drapery installation guides that follow this pocket guide. Lutron documents 085319 and 085327 are the Alena drapery specification submittals.
| Document | Type | Revision | Date |
|---|---|---|---|
| 085319Alena Drapery Specification Submittal | Specification Submittal | I | Dec 2025 |
| 085327Alena Drapery Specification Submittal: QS Wireless System (All Models) | Specification Submittal | L | Dec 2025 |
| 086117Drapery Specification Submittal: D105 System, Capacity | Specification Submittal | D | May 2026 |
| 086118Drapery Specification Submittal: D145 System, Capacity | Specification Submittal | B | May 2017 |
| 085807Alena Drapery CAD Drawing: Ceiling-Mount, Section View | CAD Drawing | B | |
| 085821Drapery CAD Drawing: All Pinch Pleat Master Carriers, Detail Views | CAD Drawing | A | |
| 085274Hard Wired Power Supply Specification Submittal | Specification Submittal | D | Aug 2014 |
| Drapery Revit Family: Ceiling Mount | Revit Family | ||
| Drapery Revit Family: Dual (Ceiling Mount) | Revit Family | ||
| Drapery Revit Family: Dual (Wall Mount) | Revit Family |
Revisions of 045983
This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.
| Revision | Date | Status |
|---|---|---|
| A | Sep 2024 | Current. The file on assets.lutron.com. Checked 15 Oct 2026. |
Not covered in 045983, and what to read next
Lutron document 045983 gives no drapery drive, wiring or fabric hanging, and names no model numbers for the pocket parts.
Publisher and citation for document 045983
Lutron Electronics Co., Inc. publishes document 045983, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 15 October 2026.
Lutron and Sivoia QS are trademarks of Lutron Electronics Co., Inc.
Reviewed by Edmond Hong, Technical Specialist, New Way.
Specifying Sivoia QS?
New Way supplies and installs Lutron Sivoia QS shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.
The form opens with document 045983 filled in.