You searched and this document matched it.
See all results085410 · CAD Drawing · Rev A · English · PDF, DWG, DXF
Lutron Sivoia QS Roller Shades CAD Drawing: Roller 100/150/300 Dual Narrow Coupled, Elevation View (085410)
Lutron's elevation of Sivoia QS Roller 100/150/300 shades in the dual narrow coupled configuration, ceiling mount drawn.
Lutron 085410 Rev A, Sivoia QS Roller Shades CAD Drawing: Roller 100/150/300 Dual Narrow Coupled, Elevation View. https://assets.lutron.com/a/documents/085410.pdf, via https://newwaykl.com/resources/lutron/roller-shades/sivoia-qs/lutron-sivoia-qs-roller-shades-cad-drawing-085410/
About document 085410
Lutron drawing 085410, Rev A, is view 2, the 1/4 scale elevation titled R100 - Dual Narrow Coupled: two minimum light gaps, one unlabeled dimension, the mounting note and the clearance note.
What drawing 085410 covers
Lutron document 085410 has these six sections, all on its one page.
- Elevation view
- Clearance note on site adjustment
- Mounting note, ceiling mount shown
- Legend with view markers 1 and 2
- Minimum light gap callouts
- Title block with scale, view and revision
Specifications in 085410
Lutron document 085410 prints seven values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.
- Minimum light gap
- 0.75 in (19 mm)
- Minimum light gap (between shades)
- 1.5 in (38 mm)
- Unlabeled dimension
- 8.50 in (215 mm)
Mounting note
PDF page 1 of 085410, opens in a new tab- Bracket mounting
- Ceiling or wall; ceiling mount shown
Title block
PDF page 1 of 085410, opens in a new tab- Scale
- 1/4
- View
- 2
- Revision
- A
Facts Lutron states in 085410
The values Lutron document 085410 states, as published:
- Subject
- Roller 100/150/300 dual narrow coupled shades, titled R100 - Dual Narrow Coupled, elevation view
- Minimum light gap
- 0.75 in (19 mm)
- Minimum light gap between shades
- 1.5 in (38 mm)
- Other dimension printed
- 8.50 in (215 mm), unlabeled
- Mounting
- Ceiling or wall on the same bracket, per Lutron's note, ceiling mount drawn
- Clearances
- Factory-supplied shades have the clearances they need, and the installer keeps them once adjustment features are used
- Adjustments at maximum roll diameter
- Not every adjustment is available at the maximum roll diameter
- Legend
- A top view of the coupled run with the view markers 1 and 2
- Scale, view and revision
- 1/4 scale, view 2, revision A
- File formats
- PDF (one page), DWG and DXF
- Not on the drawing
- No minimum shade height, no labeled pocket, tube, bracket or fastener dimension and no issue date printed
Questions about document 085410
The answers come from Lutron document 085410 and New Way's record of it.
What is Lutron drawing 085410?
Lutron's one-sheet CAD elevation at 1/4 scale, published as PDF, DWG and DXF with no date printed.
Which revision of 085410 is current?
Rev A is the revision Lutron publishes. New Way checked it against assets.lutron.com on 16 October 2026.
Which roller shades does 085410 cover?
Lutron Sivoia QS roller shades.
What light gap do dual narrow coupled shades need?
Lutron drawing 085410 prints a minimum light gap between shades of 1.5 in (38 mm). A separate minimum light gap of 0.75 in (19 mm) is printed on the same elevation.
Is a minimum shade height printed?
No, Lutron drawing 085410 prints the two light gaps and an unlabeled 8.50 in (215 mm) dimension only. No minimum shade height appears on this elevation.
Can the dual narrow coupled bracket go on a wall?
Yes, Lutron's note on drawing 085410 says the bracket supports ceiling or wall mounting. The elevation itself draws the ceiling mount.
What does the clearance note on drawing 085410 ask of the installer?
Lutron's note on drawing 085410 says a shade fitted as the factory supplies it already has the clearances it needs.
Once adjustment features are used, the installer must keep the clearances. Not every adjustment is available at the maximum roll diameter.
Other Sivoia QS CAD drawings
CAD drawings for the same Sivoia QS system:
| Document | Drive class | Revision | Date |
|---|---|---|---|
| 085407Roller Shades CAD Drawing: Roller 100/150/300 Coupled Shade, Elevation View | Roller 100, Roller 300 | A | |
| 085400Roller Shades CAD Drawing: Roller 100/150/300 Dual Left Sub-Bracket, Detail Drawing | Roller 100, Roller 300 | A | |
| 085403Roller Shades CAD Drawing: Roller 100/150/300 Dual Right Sub-Bracket, Detail Drawing | Roller 100, Roller 300 | A | |
| 085517Roller 100 CAD Drawing: Dual Narrow Sub-Bracket, Detail Drawing | Roller 100 | A |
Documents used with 085410
Lutron drawings 085400, 085403 and 085517 are the dual left, dual right and Roller 100 dual narrow sub-bracket details. Lutron drawing 085407 is the coupled shade elevation view, and 045190 the Roller 100 dual mount chassis installation guide.
| Document | Type | Revision | Date |
|---|---|---|---|
| 045190Roller 100 Installation Guide: Dual Mount Chassis | Installation Guide | B | Dec 2012 |
| 086106Roller Shades Specification Submittal: Roller 100 | Specification Submittal | B | May 2017 |
| 045627ROLLER 100/150/300 – Pocket Mount Chassis Installation Guide | Installation Guide | A | Feb 2019 |
| 045211Roller Shades Installation Guide: Angled Coupler Chassis Addendum | Installation Guide | A | |
| Roller Shades Revit Family: Dual Roller 100/150/200 (Ceiling Mount) | Revit Family | ||
| Roller Shades Revit Family: Dual Roller 100/150/200 (Wall Mount) | Revit Family | ||
| Roller Shades Revit Family: Roller 100/150/200 (Pocket Mount) | Revit Family | ||
| Roller Shades Revit Family: Roller 100/150/200 (Wall Mount) | Revit Family | ||
| 0853144-Group RF Remote Control Specification Submittal | Specification Submittal | C | May 2016 |
| Roller Shades Revit Family: QS Shading Keypad 3-Group 3-Button with Raise/Lower | Revit Family |
Revisions of 085410
This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.
| Revision | Date | Status |
|---|---|---|
| A | Not stated | Current. The file on assets.lutron.com. Checked 16 Oct 2026. |
Not covered in 085410, and what to read next
Lutron drawing 085410 prints the elevation only, with no shade height and no labeled pocket, tube, bracket or fastener dimension.
Publisher and citation for document 085410
Lutron Electronics Co., Inc. publishes document 085410, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 16 October 2026.
Lutron and Sivoia QS are trademarks of Lutron Electronics Co., Inc.
Reviewed by Edmond Hong, Technical Specialist, New Way.
Specifying Sivoia QS?
New Way supplies and installs Lutron Sivoia QS shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.
The form opens with document 085410 filled in.