You searched and this document matched it.
See all results085575 · CAD Drawing · Rev D · English · PDF, DWG, DXF
Lutron Serena Roller Shades CAD Drawing: Battery, Architectural Fascia, Section View (085575)
Lutron's section view of a Serena or Triathlon battery roller shade with an architectural fascia and top back cover 5.00 in (127 mm) high.
Lutron 085575 Rev D, Serena Roller Shades CAD Drawing: Battery, Architectural Fascia, Section View. https://assets.lutron.com/a/documents/085575.pdf, via https://newwaykl.com/resources/lutron/roller-shades/triathlon/lutron-serena-roller-shades-cad-drawing-085575/
About document 085575
Lutron drawing 085575, revision D, is the architectural fascia section view at scale 1/2: fascia height and depth, tube and roll-up diameters, tube centers, one unlabeled dimension, glazing and hembar labels and three notes.
What drawing 085575 covers
Lutron document 085575 has these ten sections, all on its one page.
- Sheet header: Serena/Triathlon, battery, architectural fascia
- Section view: fascia with top back cover
- Tube diameter and maximum roll-up
- Tube center dimensions
- One further unlabeled dimension
- Glazing and hembar labels
- Mounting note: wall or ceiling, wall shown
- Legend (top view), view markers 1 and 2
- Clearance and adjustment note for the installer
- Title block: Triathlon, number, scale, view, revision
Specifications in 085575
Lutron document 085575 prints 20 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.
View 1 (section view)
PDF page 1 of 085575, opens in a new tab- Fascia with top back cover height
- 5.00 in (127 mm)
- Fascia with top back cover depth
- 3.375 in (86 mm)
- Tube diameter (Ø)
- 1.67 in (43 mm)
- Maximum roll-up diameter (Ø)
- 2.60 in (64 mm)
- Tube center
- 1.63 in (42 mm)
- Tube center
- 3.525 in (90 mm)
- Unlabeled dimension
- 0.38 in (9 mm)
- Glazing
- Typical
- Hembar
- Varies
- Legend (top view)
- Top view of the shade with view markers 1 and 2
- Mounting
- Several mounting configurations allowed; the bracket supports wall or ceiling mounting, wall mount shown
- Clearances
- A shade installed as the factory supplies it has the clearances it needs; if adjustment features are used, the installer keeps them
- Adjustments
- Not all adjustments are available at the maximum roll diameter
Title block
PDF page 1 of 085575, opens in a new tab- Sheet header
- Serena/Triathlon, battery, architectural fascia
- Product named in the title block
- Triathlon
- Drawing title
- Section view
- Drawing number
- 085575
- Scale
- 1/2
- View
- 1
- Revision
- D
Facts Lutron states in 085575
The values Lutron document 085575 states, as published:
- What the drawing shows
- A section through a Serena or Triathlon battery shade with an architectural fascia and top back cover, wall mount drawn
- Fascia height
- 5.00 in (127 mm), fascia with top back cover
- Fascia depth
- 3.375 in (86 mm), fascia with top back cover
- Tube diameter
- 1.67 in (43 mm)
- Maximum roll-up
- 2.60 in (64 mm) diameter
- Tube center
- Two dimensions labeled tube center: 1.63 in (42 mm) and 3.525 in (90 mm)
- Other printed dimension
- 0.38 in (9 mm), unlabeled
- Mounting
- One bracket supports wall or ceiling mounting, and the wall mount is drawn
- Clearances
- A factory-supplied shade has the clearances it needs, and the installer keeps them if adjustment features are used
- Adjustment limit
- Not all adjustments are available at the maximum roll diameter
- Legend
- A top view of the shade with view markers 1 and 2, this sheet being view 1
- Scale, view and revision
- Scale 1/2, view 1, revision D, Triathlon named, no date printed
- File formats
- PDF of one page, DWG and DXF
- Not on the sheet
- Battery type and count, shade size limits, fascia lengths and fixing sizes are not stated in the document
Questions about document 085575
The answers come from Lutron document 085575 and New Way's record of it.
What is Lutron drawing 085575?
Lutron's one-page fascia section of a battery shade, drawn with the bracket on the wall and the glazing typical. Lutron prints no date on the sheet.
Which revision of 085575 is current?
Rev D is the revision Lutron publishes. New Way checked it against assets.lutron.com on 16 October 2026.
Which roller shades does 085575 cover?
Lutron Triathlon roller shades.
Does drawing 085575 apply to Serena or to Triathlon?
Lutron drawing 085575 carries the header Serena/Triathlon, battery, architectural fascia, and its title block names Triathlon. Lutron drawing 085575 does not separate the two shades on the sheet.
Who is responsible for clearances on drawing 085575?
Lutron drawing 085575 states that a shade installed as the factory supplies it has the clearances it needs to operate. Lutron puts the job of keeping clearances on the installer when the adjustment features are used.
Are all adjustments available at the maximum roll diameter?
No, Lutron drawing 085575 notes that not all adjustments are available at the maximum roll diameter. Lutron dimensions the maximum roll-up at 2.60 in (64 mm) and does not list which adjustments are limited.
How much space does the architectural fascia take?
Lutron drawing 085575 dimensions the fascia with top back cover at 5.00 in (127 mm) high and 3.375 in (86 mm) deep.
Can the fascia shade mount to the ceiling instead of the wall?
Yes, Lutron drawing 085575 notes that several mounting configurations are allowed. The bracket supports wall or ceiling mounting, and the wall mount is the one drawn.
Other Triathlon CAD drawings
CAD drawings for the same Triathlon system:
All 13 Triathlon CAD drawingsDocuments used with 085575
Lutron drawing 085576 is the Triathlon WIDR battery architectural fascia section view. Lutron drawings 085567 and 085568 are the fabric wrapped fascia section and elevation views of the battery shade.
| Document | Type | Revision | Date |
|---|---|---|---|
| 085312Serena Roller Shades Specification Submittal | Specification Submittal | K | Sep 2025 |
| 085314Sivoia QS 4-Group RF Remote Control Specification Submittal | Specification Submittal | C | May 2016 |
| 045949Roller Shades Installation Guide: Architectural Fascia | Installation Guide | B | Jul 2024 |
| 045583Roller Shades Installation Guide: WIDR Architectural Fascia | Installation Guide | A | Jan 2017 |
| Roller Shades Revit Family | Revit Family | ||
| 085276Serena 10 Output Power Panel Power Supply (12 V) Specification Submittal | Specification Submittal | C | May 2016 |
| 085283Serena Individual Plug-In Power Supply Specification Submittal | Specification Submittal | D | Nov 2018 |
| Serena Application Note: Blink Codes | Application Note | ||
| 048561Serena Application Note: Optimizing Battery Life in Shades | Application Note | F | Oct 2024 |
| 3672208Product Brochure: Shading Solutions | Product Brochure | M | Dec 2020 |
Revisions of 085575
This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.
| Revision | Date | Status |
|---|---|---|
| D | Not stated | Current. The file on assets.lutron.com. Checked 16 Oct 2026. |
Not covered in 085575, and what to read next
Lutron drawing 085575 gives the fascia section only, not shade size limits, battery details, fascia lengths, fixings or fitting steps.
Publisher and citation for document 085575
Lutron Electronics Co., Inc. publishes document 085575, Rev D, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 16 October 2026.
Lutron, Triathlon and Serena are trademarks of Lutron Electronics Co., Inc.
Reviewed by Edmond Hong, Technical Specialist, New Way.
Specifying Triathlon?
New Way supplies and installs Lutron Triathlon shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.
The form opens with document 085575 filled in.