Contact Us
Opens in a new tab

085812 · CAD Drawing · Rev A · English · PDF, DWG, DXF

Lutron Sivoia QS Drapery CAD Drawing: Corner Mount (085812)

Lutron's four-sheet CAD drawing of a drapery track mounted around a corner, in plan view, as PDF, DWG and DXF.

About document 085812

Lutron drawing 085812, revision A, is the corner mount CAD drawing: wall, ceiling and dual ceiling mount plans at 1/4 scale with corner minimums and a 24 in minimum system width.

What drawing 085812 covers

Lutron document 085812 has these four sections. Each link opens the PDF at that page in a new tab.

  1. Table of contents and installer clearance note, opens in a new tab page 1
  2. Corner wall mount plan view, opens in a new tab page 2
  3. Corner ceiling mount plan view, opens in a new tab page 3
  4. Dual corner ceiling mount plan view, opens in a new tab page 4

Specifications in 085812

Lutron document 085812 prints 15 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.

Sheet 2: corner wall mount plan view

PDF page 2 of 085812, opens in a new tab
Minimum system width
24 in
Minimum clearance
3.50 in (89 mm), printed twice
Minimum
4.00 in (102 mm), printed twice
Scale; mount shown
1/4; wall mount system shown

Sheet 3: corner ceiling mount plan view

PDF page 3 of 085812, opens in a new tab
Minimum system width
24 in
Minimum clearance
3.50 in (89 mm), printed twice
Minimum
4.00 in (102 mm), printed twice
Scale; mount shown
1/4; ceiling mount system shown

Sheet 4: dual corner ceiling mount plan view

PDF page 4 of 085812, opens in a new tab
Minimum system width
24 in
Minimum clearance
3.50 in (89 mm), printed twice
Minimum
4.00 in (102 mm), printed twice
Minimum
9.50 in (241 mm), printed twice
Minimum clearance
5.50 in (140 mm), printed twice
Scale; mount shown
1/4; ceiling mount system shown

Facts Lutron states in 085812

The values Lutron document 085812 states, as published:

Configurations drawn
Three corner plans, wall mount, ceiling mount and dual (two-track) ceiling mount, with no elevation or section
Minimum system width
24 in on every plan, in inches only
Corner minimums, single track
3.50 in (89 mm) minimum clearance and 4.00 in (102 mm) minimum, each printed twice on the wall mount and ceiling mount plans
Corner minimums, dual ceiling mount
  • 9.50 in (241 mm) minimum, printed twice
  • 5.50 in (140 mm) minimum clearance, printed twice
  • Plus the single-track plans' 3.50 in (89 mm) and 4.00 in (102 mm) minimums
Scale
Plan views at 1/4 scale
Revision and date
Revision A on all four sheets, no date printed
Mount noted on each plan
Sheet 2 is marked wall mount system shown, and sheets 3 and 4 ceiling mount system shown
Installer responsibility
The installer must keep proper clearances for the fabric panels actually chosen, since the drawing's clearances suit typical panels
Files published
PDF of four sheets, with DWG and DXF versions of drawing 085812 on assets.lutron.com

Questions about document 085812

The answers come from Lutron document 085812 and New Way's record of it.

What is Lutron document 085812?

Lutron drawing 085812, titled Drapery Track - Corner Mount, opens with a table of contents and the installer clearance note.

Which revision of 085812 is current?

Rev A is the revision Lutron publishes. New Way checked it against assets.lutron.com on 16 October 2026.

Which drapery tracks does 085812 cover?

Lutron Sivoia QS drapery tracks.

Which corner conditions does Lutron drawing 085812 show?

Lutron drawing 085812 shows three plan views: a corner wall mount, corner ceiling mount and dual corner ceiling mount. Lutron gives no elevation or section on this drawing.

Is Lutron drawing 085812 available for CAD?

Yes, Lutron publishes drawing 085812 as DWG and DXF files beside the four-sheet PDF. The corner plans can be placed straight into a CAD drawing.

Which minimums does Lutron drawing 085812 print at a single-track corner?

Lutron drawing 085812 marks 3.50 in (89 mm) minimum clearance and 4.00 in (102 mm) minimum at the corner. The wall mount plan and the ceiling mount plan print the same pair.

Who is responsible for clearances once the fabric is chosen?

On every sheet, Lutron drawing 085812 says a track installed as supplied has the clearances typical fabric panels need. The installer must keep proper clearances for the fabric panels actually selected.

Which minimums does the dual corner plan of Lutron drawing 085812 print?

Lutron drawing 085812 prints 9.50 in (241 mm) minimum and 5.50 in (140 mm) minimum clearance on the dual corner ceiling mount plan. The single-track minimums, 3.50 in (89 mm) and 4.00 in (102 mm), appear there too.

Ask about 085812

Other Sivoia QS CAD drawings

CAD drawings for the same Sivoia QS system:

All 33 Sivoia QS CAD drawings

Documents used with 085812

Lutron drawing 085812 covers the corner condition only; 085808, 085807 and 085809 draw the straight wall, ceiling and recessed mounts. Lutron drawing 085811 is the standard 90 degree curved track, and 045982 the Sivoia QS drapery installation guide.

Revisions of 085812

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
ANot statedCurrent. The file on assets.lutron.com. Checked 16 Oct 2026.

Not covered in 085812, and what to read next

Lutron drawing 085812 shows plan views only, with no elevation, section, bracket detail, fixing schedule or wiring.

  • Brackets: 085810, the bracket detail CAD drawing
  • Straight runs: 085808 or 085807, the wall and ceiling mount CAD drawings

Publisher and citation for document 085812

Lutron Electronics Co., Inc. publishes document 085812, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 16 October 2026.

Lutron and Sivoia QS are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Sivoia QS?

New Way supplies and installs Lutron Sivoia QS shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.

The form opens with document 085812 filled in.