About document 3684025
Lutron document 3684025, the Custom Curved Drapery Track Worksheet, P/N 368-4025 Rev D of March 2023, sets the radius, angle, length, splice, spacing and pocket limits and the template, photo and shipping steps.
What drawing 3684025 covers
Lutron document 3684025 has these nine sections. Each link opens the PDF at that page in a new tab.
- Worksheet: checklist and order details, opens in a new tab page 1
- About standard curved drapery tracks, opens in a new tab page 2
- Before you begin: general guidelines and limitations, opens in a new tab page 2
- Submit the quote for a COM number, opens in a new tab page 2
- Constructing the template: tools, materials, paper layout, opens in a new tab page 3
- Trace the curvature and add vital information, opens in a new tab page 4
- Finishing the template: preparations and photos, opens in a new tab page 5
- Pack and ship the completed template, opens in a new tab page 6
- Appendix: qualifying the minimum radius, opens in a new tab page 6
Specifications in 3684025
Lutron document 3684025 prints 27 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.
About standard curved drapery tracks
PDF page 2 of 3684025, opens in a new tab- Corner fitted
- Inside or outside a 90 degree corner
- Bend radius
- 20 in (508 mm)
- Configurations
- Single and tandem only; every dual curved track is custom
- How to order
- myProjects: Add Product, Drapery, Product Details: Standard Curved Track; no template
General guidelines and limitations
PDF page 2 of 3684025, opens in a new tab- Radius
- Constant radius recommended; minimum 20 in (508 mm)
- Tolerance of the finished track
- Plus or minus 3/4 in (19 mm) from the template
- Clearance between track ends and walls
- 1 in (25 mm)
- Tightest inside angle
- 90°; smaller angles not allowed
- S bends and multiple bends
- Two curved tracks spliced together
- Splice location
- Straight section of track at least 16 in (406 mm) long
- Maximum one-piece track length
- 216 in (548.6 cm)
- Maximum two-piece (spliced) track length
- 360 in (914.4 cm)
- Minimum dual track spacing
- 5.5 in (140 mm) center to center
- Minimum pocket dimension, wall or ceiling mount
- 6 in (152 mm)
- Minimum pocket dimension, dual track
- 11.5 in (292 mm)
Submit your quote
PDF page 2 of 3684025, opens in a new tab- Quote basis
- Straight-length equivalent of the curved track; constant or variable radius, single, dual or tandem, splice or no splice
- Issued with the quote
- COM number and bar-coded address label for the template
Tools and materials
PDF page 3 of 3684025, opens in a new tab- Template material
- Contractor paper or poster paper only
- Masking tape
- 2 in wide or wider; no painter's tape
Build the paper layout
PDF page 3 of 3684025, opens in a new tab- Figure 3.2a, printed value
- Minimum 12 in (305 mm)
- Orientation marks
- A when made on the ceiling; B when made on the floor
Trace the curvature
PDF page 4 of 3684025, opens in a new tab- Typical wall-mounted track distance from the wall
- 3.5 in (89 mm), more where the curtain must clear handles, sills, columns or vents
- Clearance to the wall and other obstacles
- 3.5 in (89 mm) or more
- Order details entered
- COM and quote numbers; dealer and job; single or dual track with spacing; left, right or center draw; splice or no splice; ceiling, wall or pocket mount with distance from wall or pocket width; drive side viewed facing the window
Final preparations for submittal
PDF page 5 of 3684025, opens in a new tab- Template length
- Track centerline length must match the track length on the quote
- Templates per track
- One template per curved track; dual tracks may share one
- Test string length
- 20 in
Installation walk-through for 3684025
Lutron document 3684025 gives eleven steps, in the document's order, after the tools it lists.
The clearance, the check and the warning under a step are the document's own.
Tools
- Contractor paper (or poster paper)
- Masking tape, 2 in or wider (not painter's)
- Compass (optional, recommended)
- Black marker
- Scissors
- Tape measure
- Digital camera or camera-equipped smartphone
- Mailing tube
- Chalk line or string, for the radius check
Decide whether a custom track is needed
A standard curved track fits inside or outside a 90 degree corner at a 20 in (508 mm) bend radius. Lutron orders it in myProjects without a template.
Any other curve needs a custom track and this worksheet. Every dual curved track is custom.
Check: The curve is not the standard 90 degree, 20 in (508 mm) radius corner in single or tandem form
Review the limits
Check the curve against the limits in section 2.1: radius, inside angle, splices, length, dual spacing and pocket size. The finished track may differ from the template by plus or minus 3/4 in (19 mm).
Clearance: 1 in (25 mm) between track ends and walls; splice on a straight run of at least 16 in (406 mm)
Check: Length is within 216 in (548.6 cm) for one piece or 360 in (914.4 cm) spliced
Warning: Angles tighter than 90° are not allowed
Qualify the radius if unsure
Snap a chalk line or string between the two ends of the curved wall. From the midpoint of that line, run a second line at 90° to the first, out to the wall.
Mark a point on the second line 20 in from the wall. Anchor a string at that mark and cut it where it reaches the wall, a 20 in length.
Swing the string's end in an arc beside the wall.
Check: The string's arc is tighter than the wall, so the wall radius exceeds 20 in
Get the quote, COM number and label
Email a drapery track quote to Lutron's shading quotes team, based on the straight-length equivalent of the curve. State the radius type, configuration and splice.
The team returns a COM number and a bar-coded shipping label. Enter the order details on the worksheet.
Check: COM number and Lutron-issued label are in hand
Warning: A template sent without a COM number and Lutron-issued label is rejected
Build the paper layout
Tape contractor paper together close to the wall, on the ceiling or the floor, whichever follows the curve better. Tape every edge securely.
Mark the template Orientation A if made on the ceiling, or Orientation B if made on the floor.
Check: Orientation A or B is written on the template
Warning: Materials other than contractor or poster paper may be rejected
Trace the curvature
Use a compass or similar tool to keep a constant distance from the wall. Trace the track centerline onto the paper, then go over the pencil line with the black marker.
Clearance: 3.5 in (89 mm) typical from the wall for a wall-mounted track, or more to clear handles, sills, columns or vents
Check: Clearance to the wall and other obstacles is 3.5 in (89 mm) or more
Add the vital information
Write your contact details on the template or attach a business card.
Mark the centerline, the drive location or locations and both ends of the track. Mark any pocket's extents, the center of a tandem or center-draw track, the wall or pocket position and any splice.
Check: Every mark on the checklist is on the template
Prepare the template for submittal
Tape a copy of the completed worksheet page to the template and write the COM number on it. Confirm the centerline length equals the quoted track length.
Keep the template in one taped piece with an X drawn across every seam. The factory can then rejoin any piece that comes apart.
Check: Centerline length matches the quoted track length
Warning: Templates on separate sheets are rejected; each curved track needs its own template, except dual tracks
Photograph the template in place
Photograph the finished template in place. Take several more photos of the mounting surface and its surroundings, which Lutron may ask for to clarify the site.
Place the order
Process the custom curved drapery track quote as an order in myProjects before the template is sent.
Check: The quote shows as an order in myProjects
Pack and ship
Roll the template and slide it into a sturdy mailing tube. Fix the addressed COM label from the quote to the outside of the tube and ship by any carrier.
Check: The COM label is on the tube
Warning: Do not fold the template. Folding makes it hard to lay flat and may distort the curve's size and shape.
Facts Lutron states in 3684025
The values Lutron document 3684025 states, as published:
- Standard curved track
- Fits inside or outside a 90° corner, 20 in (508 mm) bend radius
- Single and tandem only
- Ordered in myProjects as a drapery product detail, no template
- Every dual curved track is custom
- Minimum radius and angle
- Radius at least 20 in (508 mm), constant radius recommended, and 90° the tightest inside angle allowed
- Tolerance
- The finished track may vary plus or minus 3/4 in (19 mm) from the template
- Clearances
- 1 in (25 mm) between the ends of the track and walls
- Wall-mounted track typically 3.5 in (89 mm) from the wall
- More where the curtain must clear handles, sills, columns or vents
- Splices
- Only in straight sections at least 16 in (406 mm) long, and S bends or multi-bend shapes need two curved tracks spliced
- Length limits
- 216 in (548.6 cm) for a one-piece track and 360 in (914.4 cm) for a two-piece spliced track
- Dual tracks and pockets
- Dual tracks at least 5.5 in (140 mm) center to center
- Minimum pocket dimension 6 in (152 mm), wall or ceiling mount
- Minimum pocket dimension 11.5 in (292 mm), dual track, allowing for stack-back
- Template materials
- Contractor paper or poster paper only
- Masking tape 2 in or wider, not painter's tape
- Traced with a compass, darkened with a black marker
- Marked Orientation A on the ceiling, B on the floor
- Marks required
- Track centerline, ends of track, pocket extents
- Drive location(s), wall or pocket position, splice, center-draw point
- Orientation, contact details and the COM number
- Submission
- Quote by email first for a COM number and bar-coded label
- Centerline length must match the quoted track length
- One track per template, dual tracks may share
- Seams taped and marked X
- Photos of the template in place
- Rolled in a mailing tube, never folded
- Rejected templates return; lead time begins after a successful resubmission
Questions about document 3684025
The answers come from Lutron document 3684025 and New Way's record of it.
What is Lutron document 3684025?
Lutron's six-page worksheet, P/N 368-4025 Rev D, reproducing the rev C of 11/2021 as a filled-in example on page 5.
Which revision of 3684025 is current?
Rev D, dated March 2023, is the revision Lutron publishes. New Way checked it against assets.lutron.com on 16 October 2026.
Which drapery tracks does 3684025 cover?
Lutron Sivoia QS drapery tracks.
When does a curved drapery track need a template?
Lutron document 3684025 orders a standard curved track, a 90° corner at a 20 in (508 mm) radius, in myProjects without a template. Any other curve, and every dual curved track, is custom and needs a paper template made on site.
What limits apply to a custom curved track?
Lutron document 3684025 sets a 20 in (508 mm) minimum radius and 90° as the tightest inside angle.
- Length: 216 in (548.6 cm) one piece, 360 in (914.4 cm) spliced
- Splices only on straight runs of at least 16 in (406 mm)
- Dual tracks 5.5 in (140 mm) apart, 1 in (25 mm) end clearance
What must be marked on the template?
Lutron document 3684025 requires these marks, with a completed copy of the worksheet attached.
- Track centerline, both ends, pocket extents, drive location
- Wall or pocket position, splice location, center-draw point
- Orientation (A ceiling, B floor), contact details, COM number
How can an installer check a wall's minimum radius?
Lutron document 3684025 proves the 20 in (508 mm) radius with a string test.
- A line between the wall's two ends
- From its midpoint, a line at 90° to the wall
- A mark on that line 20 in from the wall
A 20 in string from the mark arcing tighter than the wall proves the radius exceeds 20 in.
How is the template submitted?
Lutron document 3684025 has the dealer get a quote and COM number first, then order in myProjects.
- Check the template length against the quote
- Photograph the template in place and the mounting surface
- Roll it into a mailing tube with the Lutron-issued label
Lutron rejects a template sent without the COM number and label.
Other Sivoia QS CAD drawings
CAD drawings for the same Sivoia QS system:
All 33 Sivoia QS CAD drawingsDocuments used with 3684025
Lutron document 3684025 is the ordering worksheet for a custom curved drapery track, with no DWG or DXF published. Lutron drawing 085811 is the standard 90 degree curved track, needing no template; 085812 is the corner mount CAD drawing.
| Document | Type | Revision | Date |
|---|---|---|---|
| 086117Drapery Specification Submittal: D105 System, Capacity | Specification Submittal | D | May 2026 |
| 086118Drapery Specification Submittal: D145 System, Capacity | Specification Submittal | B | May 2017 |
| 045985Installation Guide: Wireless Drapery Lite System | Installation Guide | A | Nov 2024 |
| 045982Drapery Installation Guide | Installation Guide | A | Sep 2024 |
| Drapery Revit Family: Ceiling Mount | Revit Family | ||
| Drapery Revit Family: Dual (Ceiling Mount) | Revit Family | ||
| Drapery Revit Family: Dual (Wall Mount) | Revit Family | ||
| Drapery Revit Family: Standard Curved (Ceiling Mount) | Revit Family | ||
| Drapery Revit Family: Standard Curved (Wall Mount) | Revit Family | ||
| 085274Hard Wired Power Supply Specification Submittal | Specification Submittal | D | Aug 2014 |
Revisions of 3684025
This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.
| Revision | Date | Status |
|---|---|---|
| D | Mar 2023 | Current. The file on assets.lutron.com. Checked 16 Oct 2026. |
What changed in this revision: Lutron document 3684025 prints no change note. In Lutron document 3684025, the rev C (November 2021) worksheet reproduced as a filled-in example on page 5 lists 21 checklist items, while the rev D (March 2023) checklist on page 1 lists 22; the added item asks the dealer to confirm that the track length on the template matches the length on the quote.
Not covered in 3684025, and what to read next
Lutron document 3684025 does not cover the standard 90 degree curved track, the drive, wiring or mounting the finished track.
Publisher and citation for document 3684025
Lutron Electronics Co., Inc. publishes document 3684025, Rev D, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 16 October 2026.
Lutron and Sivoia QS are trademarks of Lutron Electronics Co., Inc.
Reviewed by Edmond Hong, Technical Specialist, New Way.
Specifying Sivoia QS?
New Way supplies and installs Lutron Sivoia QS shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.
The form opens with document 3684025 filled in.