045913 · Installation Guide · Rev C · Sep 2023 · English, French, Spanish · PDF, 6 pages, 21.6 MB

Lutron Palladiom Wire-Free Roller Shades Installation Guide: Setup (045913, rev C)

Lutron's chassis installation and setup guide for Palladiom Wire-Free roller shades, models LBMRJ-C and LBMRK-C.

About document 045913

Lutron document 045913, Rev C of September 2023, is the Palladiom Wire-Free chassis installation and setup guide: measuring and bracket mounting, hanging the shade, loading the D-cell batteries, assigning a Pico remote and setting limits.

What guide 045913 covers

Lutron document 045913 has these twelve sections. Each link opens the PDF at that page in a new tab.

  1. Safety instructions, components and models, opens in a new tab page 1
  2. EU declaration of conformity and FCC / IC information, opens in a new tab page 1
  3. Important installation notes, opens in a new tab page 1
  4. Tools needed, opens in a new tab page 1
  5. Measure and mark for a single shade, opens in a new tab page 1
  6. Measure and mark for ganged shades, opens in a new tab page 1
  7. Mount the shade brackets, opens in a new tab page 1
  8. Install foot covers, opens in a new tab page 2
  9. Install the slide ring on the shade, opens in a new tab page 2
  10. Hang the shade in the brackets, opens in a new tab page 2
  11. Install batteries, opens in a new tab page 2
  12. Final shade setup: power, Pico assignment and limits, opens in a new tab page 2

Specifications in 045913

Lutron document 045913 prints 39 values in the groups the document uses, each with the document's unit. A row names the catalog codes it applies to. The page link beside each group opens the PDF where the group starts.

EDU voltage range
4.5 to 9.0 V DCModels: QSFC-EDU-BP-C, QSSC-EDU-PLDM-C
EDU voltage
9.0 V DCModels: QSFCJ-EDU-6D-RPL, QSFCK-EDU-6D-RPL
EDU voltage
6.0 V DCModels: QSFCJ-EDU-4D-RPL, QSFCK-EDU-4D-RPL
EDU voltage
4.5 V DCModels: QSFCJ-EDU-3D-RPL, QSFCK-EDU-3D-RPL
EDU power
5 WModels: QSFC-EDU-BP-C, QSSC-EDU-PLDM-C, QSFCJ-EDU-6D-RPL, QSFCJ-EDU-4D-RPL, QSFCJ-EDU-3D-RPL, QSFCK-EDU-6D-RPL, QSFCK-EDU-4D-RPL, QSFCK-EDU-3D-RPL
EDU torque
6 in-lb (0.68 N·m)Models: QSFC-EDU-BP-C, QSSC-EDU-PLDM-C, QSFCJ-EDU-6D-RPL, QSFCJ-EDU-4D-RPL, QSFCJ-EDU-3D-RPL, QSFCK-EDU-6D-RPL, QSFCK-EDU-4D-RPL, QSFCK-EDU-3D-RPL
FCC ID
JPZ0137Models: LBMRJ-C
IC
2851A-JPZ0137Models: LBMRJ-C
HVIN
RFB-AModels: LBMRJ-C
Emissions class
FCC part 15 Class B digital device; Canadian ICES-003 Class B

EU declaration of conformity

PDF page 1 of 045913, opens in a new tab
Radio equipment declared to Directive 2014/53/EU
Declared; full text at lutron.com/cedocModels: LBMRK-C
Shims supplied
1 with each bracket
Bracket foot covers
Included with wall and ceiling brackets

Important installation notes

PDF page 1 of 045913, opens in a new tab
Load each shade bracket must support
400 lbs (181.4 kg)
Installers needed for shades over 48 in (1219 mm)
2 people
Pocket or recess mounting
Not suitable
Pilot drill for the included mounting screws
1/8 in (#31)
Driver bits
#2 Phillips driver bit in the power drill; magnetic #1 Phillips screwdriver
Batteries
1.5 V D-cell alkaline, 3, 4 or 6 by shade size, available separately
Bracket-to-bracket width tolerance
± 1/8 in (3 mm)
Rollup radius (RR)
Rollup diameter / 2, with the diameter on the original shade quote
Jamb bracket mounting height below the top of the jamb
RR minus 1/2 in (13 mm) minimum
Bracket mounting depth for free battery access
5/8 in (16 mm) maximum
Rear of bracket to window, Palladiom bottom bar
RR minus 1-1/8 in (29 mm) minimum
Rear of bracket to window, Architectural, Designer and Sealed bottom bars
RR minus 1-5/8 in (41 mm) minimum
Ganged shades, total system width
Sum of the bracket-to-bracket widths on the box labels, each measured to the centreline of the center brackets
Idler end bracket screws (ceiling mount drawn)
2, outside edge on the bracket-to-bracket mark
Idler center bracket screws (ceiling mount drawn)
4, center of the bracket foot on the bracket-to-bracket mark
Idler jamb bracket screws
2, after the socket plate screw is removed and the socket plate separated from the mounting plate; the socket plate and its screw then go back on
Operator end bracket screws (wall, door and ceiling mount drawn)
4, outside edge on the bracket-to-bracket mark
Operator center bracket screws (wall, door and ceiling mount drawn)
4, center of the bracket on the bracket-to-bracket mark
Operator jamb bracket screws
2
Retention clip screws on the back of the slide ring
2
Ribs on the slide ring
4, aligned with the grooves on the shade
Obstruction distance from the battery door that allows the sleeve to be cut
3 in (76 mm) or more
Sleeve clearance below which the shade comes off the brackets
Less than 3 in (76 mm)
Pico assignment, hold on the Close button
10 seconds
Enter limit setting, hold on Open and Raise
10 seconds
Save a limit, hold on Open or Close
10 seconds

Installation walk-through for 045913

Lutron document 045913 gives 17 steps, in the document's order, after the tools and fixings it lists.

The clearance, the check and the warning under a step are the document's own.

Tools

  • Power drill / driver
  • #2 Phillips driver bit
  • 1/8 in (#31) drill bit
  • Tape measure
  • Pencil
  • Magnetic #1 Phillips screwdriver
  • Level or laser level
  • 1.5 V D-cell alkaline batteries, sold separately

Fixings

  • Mounting screws supplied with the brackets, quantity and type by kit
  • Or other fasteners suited to the surface
  • One shim per bracket (supplied)
  • Bracket foot covers for wall and ceiling brackets (supplied)
  • Idler jamb bracket socket plate screw (supplied on the bracket)
  • 2 retention clip screws on the back of the slide ring (supplied)
  1. Check the kit and read the notes

    Match the brackets to the order; each has a shim, and wall and ceiling types a foot cover. Keep clearance from trim, ceilings, corners, hardware, cranks, lock levers, other shades and drapery.

    Shades over 48 in (1219 mm) take two people, and every bracket goes into blocking or structure.

    Check: Correct brackets for the mount and operator side; blocking or other suitable structural material behind each bracket

    Warning: Not suitable for a pocket or recess; each bracket must carry 400 lbs (181.4 kg)

  2. Mark an outside mount

    Measure across the top of the window and mark the half-way point. Read the bracket-to-bracket width from the shade box label.

    Mark half of it to the left of center and half to the right, then measure mark to mark.

    Clearance: Mark-to-mark distance equal to the bracket-to-bracket width within ± 1/8 in (3 mm)

    Check: Marks centered on the window and the right distance apart

  3. Mark an inside-mount shade on the ceiling

    Read the bracket-to-bracket width from the box label and measure jamb to jamb at the top of the opening. Then measure in from the front edge of the opening towards the glass and mark the mounting depth you want.

    Clearance: Jamb to jamb equal to the bracket-to-bracket width within ± 1/8 in (3 mm); depth 5/8 in (16 mm) or less for free battery access

    Check: Opening width matches the shade; depth leaves the battery door reachable

    Warning: Brackets set deeper than 5/8 in (16 mm) mean the shade comes out of the brackets for every battery change

  4. Mark an inside-mount shade on the jambs

    Check the jamb-to-jamb width against the box label as in step 3. On each jamb mark the bracket height down from the opening top and the depth in from the front edge.

    Work out the rollup radius as half the rollup diameter on the quote. Keep the bracket height at least that radius minus 1/2 in (13 mm) below the top of the jamb.

    Clearance: Height at least RR minus 1/2 in (13 mm). Bracket rear to window at least RR minus 1-1/8 in (29 mm), Palladiom bar, or RR minus 1-5/8 in (41 mm), other bars.

    Check: Fabric roll and bottom bar clear the window and the top of the jamb

  5. Mark a ganged run

    Mark the window center and add the bracket-to-bracket widths from every box label into the total system width. Mark half of that to the left of center on a level line.

    From that mark, step off shade 1's width to the right, then shade 2's, and measure end to end. Every inside-mount rule in step 4 also applies to a ganged inside mount.

    Clearance: End-to-end distance equal to the total system width; each shade's width within ± 1/8 in (3 mm), measured to the centerline of the center brackets

    Check: Center bracket of each shade is in the next shade's box. Wall center brackets are reversible, ceiling ones are not.

  6. Mount the idler bracket

    Line the idler bracket up with its marks and mark the holes. Drill 1/8 in (#31) pilots where needed and fix it with the supplied screws or surface fasteners.

    Idler end bracket: outside edge on the mark, 2 screws. Idler center bracket: foot centered on the mark, 4 screws.

    Idler jamb bracket: socket plate screw out, plates parted, 2 screws, socket plate refitted. Holes are elongated: level and align the bracket, shim if needed, confirm the width, then tighten.

    Check: Bracket level, aligned and at the marked width before final tightening

    Warning: Risk of falling objects: follow every mounting instruction

  7. Mount the operator bracket

    Fix the operator bracket the same way on the operator-side marks. Operator end bracket on a wall, door or ceiling: outside edge on the mark, 4 screws.

    An operator center bracket sits centered on the mark and takes 4. An operator jamb bracket is set on its marks and fixed with 2 screws.

    Check: Both brackets level with each other and at the correct width

  8. Fit the bracket foot covers

    Make any last adjustment to bracket position first, because the covers hide the fastener heads. Set a cover on the mounting surface and slide it over the bracket foot; repeat for each bracket.

    Check: Every bracket final, level and unobstructed before the covers go on

  9. Convert the slide ring for a left operator

    Skip to step 10 for a right operator or a ceiling-mounted bracket.

    Wall and jamb brackets leave the factory set for a right operator. For a left-operator shade on those brackets, remove the two retention clip screws from the back of the slide ring.

    Move the clip to the opposite side, fit one screw loosely and keep the second to hand.

    Check: Retention clip on the side that will sit on top

    Warning: Risk of falling objects: the slide ring must be secured with the retention clip as described

  10. Snap the slide ring onto the shade

    Where step 9 was skipped, first take one retention clip screw out of the slide ring and loosen the other. After step 9 go straight on.

    Orient the shade's operator end as the pictures show for the bracket type and operator side. The clip sits on top, opposite the ribbon cable.

    Line the 4 ribs on the slide ring up with the shade's grooves and snap it on. Swing the clip back, refit the second screw and tighten both firmly.

    Check: Both retention clip screws tight; clip on top, ribbon cable opposite

  11. Hang the shade

    Push the idler into the idler bracket socket until it clicks. Pull the shade back gently to feel the resistance that confirms the idler is engaged.

    Line the slide ring's rear channels up with the operator bracket tracks and slide the shade in until it clicks. Take off any packaging still on the fabric roll.

    Check: Audible click at both ends; resistance when the shade is pulled

    Warning: Risk of falling objects: follow every hanging instruction

  12. Open the battery door

    Take hold of the fabric roll at the drive end and draw it out from the bracket. Push the battery door in and then up to release it.

    Let it hang below the opening on its ribbon cable.

    Check: Door hanging on the ribbon cable without twisting

    Warning: Never pull the battery door away from the shade; the ribbon cable ties it to the shade

  13. Load the battery sleeve

    Draw the battery sleeve right out and fill it with new 1.5 V alkaline D-cells, as marked on the sleeve. Slide the loaded sleeve back in as far as it will go.

    Where something blocks full removal but sits at least 3 in (76 mm) from the battery door, cut the sleeve at the marked points. The cells then go in one by one.

    Clearance: At least 3 in (76 mm) between the battery door and any obstruction to cut the sleeve and load the cells one by one

    Check: Fresh cells of one brand and type, orientation as marked

    Warning: With less than 3 in (76 mm) free, the shade must come off the brackets for every battery change. Extend the slide ring, press the release behind the shade and pull the idler end out.

  14. Power the shade

    Swing the battery door up into the opening, push it in and then down to lock it. The shade LED flashes a sequence of several hues once the batteries make contact.

    Check: Multi-hue LED flash seen

  15. Assign a Pico remote

    Tap the shade button so the LED shows steady green, then hold Close on the Pico for 10 seconds. The shade LED and the Pico LED flash rapidly and go out to confirm the assignment.

    For control within a Lutron system, use the setup guide supplied with that system instead.

    Check: Both LEDs flash and go out

  16. Set the open limit

    Tap the shade button for a steady green LED. Then hold Open and Raise on the Pico for 10 seconds until the LED flashes and returns to steady green.

    Move the shade with Raise and Lower to the open position you want. Hold Open for 10 seconds until both LEDs flash and go out.

    Check: Both LEDs flash and go out after the 10-second hold

  17. Set the close limit and seat the shade

    Repeat the entry sequence and move the shade to the closed position you want. Hold Close for 10 seconds until both LEDs flash and go out.

    Finish by sliding the shade fully back into the operator bracket as in step 11.

    Check: Shade seated in the bracket with a click

Other warnings Lutron prints in 045913
  • Not for use by persons with reduced capabilities or without instruction
  • Children must not play with the shade or its remote controls
  • Examine the installation often for imbalance, wear or damage
  • Cables, springs and fixings included; do not operate a shade that needs repair
  • D size alkaline batteries only, new and of one type
  • No damaged, modified or rechargeable cells
  • Protect hands and face when removing leaking cells
  • Remove all cells before nearby maintenance or long storage
  • Keep the shade and its batteries away from extreme temperature
  • Keep metal objects away from the battery compartment
  • Risk of falling objects when mounting, securing the slide ring and hanging
  • Failure to follow the instructions can cause minor to moderate injury
  • Shades over 48 in (1219 mm) need two people
  • Each bracket must be able to carry 400 lbs (181.4 kg) on blocking or structure

Requirements Lutron states in 045913

What the guide requires for a Palladiom Wire-Free shade before and during installation:

Shade models and drives
Shades LBMRJ-C and LBMRK-C, each with its electronic drive units (EDU):
  • LBMRJ-C EDUs: QSFC-EDU-BP-C, QSSC-EDU-PLDM-C, 4.5 to 9.0 V DC
  • LBMRJ-C EDUs: QSFCJ-EDU-6D-RPL, QSFCJ-EDU-4D-RPL, QSFCJ-EDU-3D-RPL
  • LBMRK-C EDUs: QSFCK-EDU-6D-RPL, QSFCK-EDU-4D-RPL, QSFCK-EDU-3D-RPL
  • RPL 6D drives 9.0 V DC, 4D drives 6.0 V DC
  • RPL 3D drives 4.5 V DC
  • Every drive printed at 5 W and 6 in-lb (0.68 N·m)
Radio identifiers and conformity
  • FCC ID JPZ0137, IC 2851A-JPZ0137 and HVIN RFB-A, in the LBMRJ-C rows
  • FCC part 15 Class B and Canadian ICES-003
  • LBMRK-C declared compliant with Directive 2014/53/EU, text at lutron.com/cedoc
Bracket kit
  • One left and one right bracket as ordered, each with one shim
  • Wall and ceiling brackets come with foot covers
  • Mounting screws vary in number and type with the brackets
  • Right-hand center bracket: shipped as the next shade's left bracket
Bracket load and substrate
Mount to blocking or other suitable structural material, with installer-chosen fasteners so each bracket supports 400 lbs (181.4 kg).
Two-person rule
Two people install any shade over 48 in (1219 mm)
Pocket mounting
  • Not suitable for a pocket or recess
  • Battery-powered shade needs set clearances to change batteries in place
  • Detailed in submittal 085708 and Application Note #802
Bracket-to-bracket width
  • Read from the shade box label and checked to ± 1/8 in (3 mm)
  • Ganged run: each shade's width adds into a total system width
  • Set out from the window center
  • Each width measured to the centerline of the center brackets
Inside-mount jamb height
  • Jamb brackets at least RR minus 1/2 in (13 mm) below the jamb top
  • RR (rollup radius) is half the rollup diameter on the shade quote
Bracket mounting depth
  • 5/8 in (16 mm) or less for free access to the battery compartment
  • Deeper brackets are allowed
  • Every battery change then means taking the shade out of the brackets
Bottom bar clearance
  • Bracket rear to window: RR minus 1-1/8 in (29 mm) min, Palladiom bottom bar
  • Or RR minus 1-5/8 in (41 mm) for Architectural, Designer and Sealed bars
Tools and pilot hole
  • Power drill or driver with a #2 Phillips bit
  • 1/8 in (#31) drill bit sized for the included screws
  • Magnetic #1 Phillips screwdriver, level or laser level, tape measure and pencil
Screws per bracket
  • Idler end bracket 2 screws (ceiling mount drawn), idler center bracket 4
  • Operator end and center brackets 4, jamb brackets 2
  • Idler jamb bracket: parted into mounting plate and socket plate before fixing
  • Every mounting hole is elongated for adjustment
Batteries
  • New 1.5 V alkaline D-cells, sold separately
  • 3, 4 or 6 cells by shade size
  • No mixing of brands or types
  • Battery life depends on shade size, fabric weight and daily use
  • Life is estimated in the shade ordering tool
  • Advertised battery life: lutron.com/optimizing-battery-life
Battery sleeve clearance
  • At least 3 in (76 mm) free: cut the sleeve at the marked points
  • Then load one cell at a time
  • Under 3 in (76 mm) free: the shade comes off for every battery change

Questions about document 045913

The answers come from Lutron document 045913 and New Way's record of it.

What is Lutron document 045913?

Lutron's six-page guide, two pages each in English, French and Spanish, printed 09/2023 and also served at the 045893 address.

Which revision of 045913 is current?

Rev C, dated September 2023, is the revision Lutron publishes. New Way checked it against assets.lutron.com on 15 October 2026.

Which roller shades does 045913 cover?

Lutron Palladiom Wire-Free roller shades. Lutron document 045913 refers readers to document 085708.

Can a Palladiom Wire-Free shade be mounted in a pocket or recess?

No. Lutron document 045913 states the Palladiom Wire-Free shade is not suitable for a pocket or recess.

The battery-powered shade needs set clearances so batteries can be changed without demounting. Specification submittal 085708 and Application Note #802 hold the detailed limits.

What must the structure behind each bracket carry?

400 lbs (181.4 kg) per shade bracket, per Lutron document 045913, on blocking or other suitable structural material. The installer chooses the fasteners; two people handle any shade over 48 in (1219 mm).

How deep can inside-mount brackets sit and still allow a battery change?

5/8 in (16 mm) or less, per Lutron document 045913, so the battery compartment stays reachable.

Deeper mounting is allowed, but the shade then comes out of the brackets for every battery change. The same applies wherever less than 3 in (76 mm) is free for the battery sleeve.

How far below the top of the jamb do jamb brackets go?

At least the rollup radius minus 1/2 in (13 mm), per Lutron document 045913. The rollup radius is half the rollup diameter shown on the shade quote.

The bracket rear must also sit at least the rollup radius minus 1-1/8 in (29 mm) from the window, Palladiom bottom bar.

How are ganged shades set out, and where is the center bracket?

Lutron document 045913 adds the bracket-to-bracket widths from each box label into a total system width. A center bracket ordered on the right ships as the left bracket of the next shade.

Half the total is marked left of center, each width stepped off to the right, the end marks checked. Widths run to the center bracket centerlines.

Ask about 045913

Other Palladiom Wire-Free installation guides

Installation guides for the same Palladiom Wire-Free system:

All 3 Palladiom Wire-Free installation guides

Documents used with 045913

Lutron serves this revision C edition of 045913 at the assets.lutron.com address for document 045893. The Palladiom Wire-Free bracket, mount and corner views are the CAD drawings 085709 to 085737.

Revisions of 045913

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
CSep 2023Current. The file on assets.lutron.com. Checked 15 Oct 2026.

Not covered in 045913, and what to read next

Lutron document 045913 prints no battery count per shade size, no bracket footprints and no control-system programming.

  • Limits: 085708, the specification submittal, and 048802, Application Note 802
  • Drive swap: 045908, the EDU replacement guide

Publisher and citation for document 045913

Lutron Electronics Co., Inc. publishes document 045913, Rev C, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 15 October 2026.

Lutron and Palladiom are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Palladiom Wire-Free?

New Way supplies and installs Lutron Palladiom Wire-Free shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.

The form opens with document 045913 filled in.