Contact Us
Opens in a new tab

085592 · Specification Submittal · Rev B · Nov 2018 · English · PDF, 7 pages, 4.6 MB

Lutron Sivoia QS 30-Output Configurable Power Panel Enclosure (Power Modules sold separately), 35V Output Specification Submittal (085592, rev B)

Lutron's specification submittal for the QSPS-30PNL-NPM, the Sivoia QS Configurable Smart Enclosure shipped without power modules.

About document 085592

Lutron document 085592, Rev B of November 2018, is the QSPS-30PNL-NPM specification submittal: ratings, breaker rules for two or three feeds, wiring, dimensions, QS Link rules, thermal dissipation, vertical mounting tolerance and three application layouts.

What submittal 085592 covers

Lutron document 085592 has these eight sections. Each link opens the PDF at that page in a new tab.

  1. Overview, features and models, opens in a new tab page 1
  2. Specifications, opens in a new tab page 2
  3. Regulatory approvals, environment, performance and warranty, opens in a new tab page 2
  4. Mounting and dimensions, opens in a new tab page 3
  5. Wiring rules, opens in a new tab page 4
  6. Application example: standalone system, opens in a new tab page 5
  7. Application example: GRAFIK Eye QS system, opens in a new tab page 6
  8. Application example: linking multiple Smart Enclosures, opens in a new tab page 7

Specifications in 085592

Lutron document 085592 prints 55 values in the groups the document uses, each with the document's unit. A row names the catalog codes it applies to. The page link beside each group opens the PDF where the group starts.

Diagnostics and testing
Built-in smart diagnostics check system communication; manual override buttons for shades and lightingModels: QSPS-30PNL-NPM
Fuses
No replaceable fuses needed for overload and miswire protectionModels: QSPS-30PNL-NPM
Enclosure
59.5 in (1511 mm) high, 3 sub-plates, no power modules, ships with empty module placeholders mountedModels: QSPS-30PNL-NPM
Power module, sold separately
Plug-in ready, 5 outputs, compliant with U.S. Department of Energy Efficiency Level VIModels: WIN-PS-5CC-R
Module pack, sold separately
12 x WIN-PS-5CC-RModels: WIN-PS-5CC-BLK12
Outputs when fully populated
30 NEC Class 2 / PELV outputs with 6 modulesModels: QSPS-30PNL
Input, per 10-output sub-plate
120 V~ to 240 V~, 50/60 Hz, 10 AModels: QSPS-30PNL-NPM
Each output, with WIN-PS-5CC-R installed
35 V DC, 143 mA, 5 WModels: QSPS-30PNL-NPM, WIN-PS-5CC-R
Load per output
1 Sivoia QS shade or drapery drive unit, or as many as 8 QS PDUsModels: QSPS-30PNL-NPM
Wire size
14 AWG to 10 AWG (2.5 mm² to 4.0 mm²), single wire, solid or strandedModels: QSPS-30PNL-NPM
Terminal screw torque
5 in-lbs (0.5 N·m)Models: QSPS-30PNL-NPM
Strip length
5/16 in (8 mm)Models: QSPS-30PNL-NPM
Circuit breaker per 10-output sub-plate
15 A required (inrush current is the limit); 16 A suits some countriesModels: QSPS-30PNL-NPM
Other circuit protection options
3 feed circuits: each sub-plate on its own 15 A or 20 A breaker; 2 feed circuits: two sub-plates share one 20 A breaker and the third sub-plate takes 15 A or 20 A (two such layouts drawn)Models: QSPS-30PNL
Wire size
22 AWG to 12 AWG (0.5 mm² to 4.0 mm²), single wire, solid or stranded; gauge sets the run lengthModels: QSPS-30PNL-NPM
Terminal screw torque
5 in-lbs (0.5 N·m)Models: QSPS-30PNL-NPM
Strip length
1/4 in (6 mm)Models: QSPS-30PNL-NPM
Output terminal blocks
30, 4-conductor, shade power and communicationModels: QSPS-30PNL-NPM
Link terminal blocks
6, 3-conductor, communication pass-throughModels: QSPS-30PNL-NPM
Listings and marks
cULus Listed; contains U.S. Department of Energy Level VI compliant power supplies; RoHS; FCC Part 15 Subpart B Class B; ICES 003 Class B; NOM certification pendingModels: QSPS-30PNL-NPM
Ambient operating temperature
32 °F to 104 °F (0 °C to 40 °C)Models: QSPS-30PNL-NPM
Relative humidity
0% to 90% non-condensingModels: QSPS-30PNL-NPM
Location
Indoor use onlyModels: QSPS-30PNL-NPM
Thermal dissipation with modules, 1 window treatment and keypad per output
60 BTU/hrModels: QSPS-30PNL-NPM
Thermal dissipation with modules, 5 W per output
156 BTU/hrModels: QSPS-30PNL-NPM
Surge protection
Plus or minus 6 kV (ANSI/IEEE C62.41-1991)Models: QSPS-30PNL-NPM
ESD protection
Plus or minus 16 kV air discharge (printed as EIC 61000-4-2)Models: QSPS-30PNL-NPM
Short circuit and miswire protection
Recovers by itself, on each power outputModels: QSPS-30PNL-NPM
Overload and over temperature protection
Recovers by itself, on each outputModels: QSPS-30PNL-NPM
Warranty
Lutron Shading Solutions standard warranty (Window Systems warranty document)Models: QSPS-30PNL-NPM
Weight
55 lb (24.9 kg)Models: QSPS-30PNL-NPM
Mounting
Surface or recess, within the run length the wire gauge allowsModels: QSPS-30PNL-NPM
Orientation
Vertical, within plus or minus 7 degreesModels: QSPS-30PNL-NPM
Height
59.5 in (1511 mm)Models: QSPS-30PNL-NPM
Other printed values (top, front, cover, left side, right side and bottom views)
59.00 in (1499 mm), 47.75 in (1060 mm), 15.875 in (403 mm), 15.125 in (394 mm), 14.375 in (365 mm), 11.00 in (279 mm), 8.00 in (203 mm), 4.21 in (107 mm), 4.15 in (105 mm), 2.69 in (68 mm), 2.43 in (62 mm) twice, 0.15 in (4 mm); not named in the textModels: QSPS-30PNL-NPM

Wiring Rules, link terminals

PDF page 4 of 085592, opens in a new tab
Wiring class
NEC Class 2 / PELV; local and national codes govern circuit separation and protectionModels: QSPS-30PNL-NPM
COM
12 AWG to 18 AWG (4.0 mm² to 1.0 mm²)Models: QSPS-30PNL-NPM
MUX and MUX
22 AWG (0.5 mm²) twisted and shielded pairModels: QSPS-30PNL-NPM
Total communication link wiring
2000 ft (610 m) maximumModels: QSPS-30PNL-NPM
Devices per Sivoia QS system
100 maximum, counting outputs and link pass-through together; each sub-plate fitted with a power module counts as 1 deviceModels: QSPS-30PNL-NPM
Interconnecting enclosures
3-pin link terminals only; never the 4-pin output terminalsModels: QSPS-30PNL-NPM

Wiring Rules, output terminals

PDF page 4 of 085592, opens in a new tab
Wiring class
NEC Class 2 / PELV; local and national codes govern circuit separation and protectionModels: QSPS-30PNL-NPM
V+ and COM
12 AWG to 18 AWG (4.0 mm² to 1.0 mm²)Models: QSPS-30PNL-NPM
MUX and MUX
22 AWG (0.5 mm²) twisted and shielded pairModels: QSPS-30PNL-NPM
V+ between outputs
Never connectedModels: QSPS-30PNL-NPM

Wiring Rules, run length per output

PDF page 4 of 085592, opens in a new tab
No shade, up to 8 PDUs
2000 ft (610 m) on 12 AWG (4.0 mm²); 1000 ft (305 m) on 16 AWG (1.5 mm²); 600 ft (183 m) on 18 AWG (1.0 mm²)Models: QSPS-30PNL-NPM
Any 1 shade or drapery drive unit, up to 1 PDU
500 ft (152 m) on 12 AWG, marked with the note that the connector supplied with Palladiom shades does not take 12 AWG wire; 200 ft (61 m) on 16 AWG; 125 ft (38 m) on 18 AWGModels: QSPS-30PNL-NPM
2 Palladiom, each 30 sq ft (2.75 sq m) or less, up to 1 PDU
Not available on 12 AWG (the Palladiom connector does not take 12 AWG); 75 ft (23 m) on 16 AWG; 50 ft (15 m) on 18 AWGModels: QSPS-30PNL-NPM
3 Palladiom, each 20 sq ft (1.8 sq m) or less, up to 1 PDU
Not available on 12 AWG; 75 ft (23 m) on 16 AWG; 50 ft (15 m) on 18 AWGModels: QSPS-30PNL-NPM
2 Sivoia QS roller 64, each 30 sq ft (2.75 sq m) or less, up to 1 PDU
200 ft (61 m) on 12 AWG; 75 ft (23 m) on 16 AWG; 50 ft (15 m) on 18 AWGModels: QSPS-30PNL-NPM
3 Sivoia QS roller 64, each 20 sq ft (1.8 sq m) or less, up to 1 PDU
200 ft (61 m) on 12 AWG; 75 ft (23 m) on 16 AWG; 50 ft (15 m) on 18 AWGModels: QSPS-30PNL-NPM
2 Sivoia QS roller 100, each 50 sq ft (4.6 sq m) or less, up to 1 PDU
200 ft (61 m) on 12 AWG; 75 ft (23 m) on 16 AWG; 50 ft (15 m) on 18 AWGModels: QSPS-30PNL-NPM

Wiring Rules, cable options

PDF page 4 of 085592, opens in a new tab
12 AWG (4.0 mm²) power and communication in one cable
QSH-CBL-L-500 standard; QSH-CBLP-L-500 for plenum installationModels: QSH-CBL-L-500, QSH-CBLP-L-500
16 AWG (1.5 mm²) power and communication in one cable
QSH-CBL-M-500 standard; QSH-CBLP-M-500 for plenum installationModels: QSH-CBL-M-500, QSH-CBLP-M-500
18 AWG (1.0 mm²) power and communication in one cable
GRX-CBL-346S-500 standard; no plenum version printedModels: GRX-CBL-346S-500

Facts Lutron states in 085592

The values Lutron document 085592 states, as published:

Capacity
  • Three sub-plates, each plug-in ready for two 5-output WIN-PS-5CC-R modules
  • Thirty outputs when six modules are fitted
  • The NPM model ships with empty module positions
Input
120 V~ to 240 V~, 50/60 Hz, 10 A per 10-output sub-plate
Circuit protection
  • 15 A breaker per 10-output sub-plate (16 A in some countries), set by inrush
  • Three feeds: one per sub-plate at 15 A or 20 A
  • Two feeds: two sub-plates share a 20 A breaker
  • Two feeds: the third sub-plate takes 15 A or 20 A
  • Feed options drawn as a diagram on page 2
Each output
35 V DC, 143 mA, 5 W, NEC Class 2 / PELV, with a WIN-PS-5CC-R installed
Devices per output
One Sivoia QS shade or drapery drive unit, or as many as 8 QS power draw units
Input wiring
  • 14 AWG to 10 AWG (2.5 mm² to 4.0 mm²), solid or stranded
  • Screws torqued to 5 in-lbs (0.5 N·m)
  • Insulation stripped 5/16 in (8 mm)
Output wiring
  • 22 AWG to 12 AWG (0.5 mm² to 4.0 mm²)
  • Screws torqued to 5 in-lbs (0.5 N·m)
  • Insulation stripped 1/4 in (6 mm)
  • Thirty 4-conductor output blocks and six 3-conductor link blocks
Conductor sizes at terminals
  • V+ and COM: 12 AWG to 18 AWG (4.0 mm² to 1.0 mm²)
  • MUX pair: 22 AWG (0.5 mm²), twisted and shielded
  • Link terminals take the same COM and MUX sizes
Environment
  • 32 °F to 104 °F (0 °C to 40 °C)
  • 0% to 90% non-condensing humidity, indoor use only
  • Thermal dissipation: 60 BTU/hr with one window treatment and keypad per output
  • Thermal dissipation at 5 W per output: 156 BTU/hr
Protection
  • Surge: plus or minus 6 kV (ANSI/IEEE C62.41-1991)
  • ESD: plus or minus 16 kV air discharge
  • Short circuit, miswire, overload, over temperature: self-recovering per output
  • No replaceable fuses
Approvals
  • cULus Listed, RoHS
  • FCC Part 15 Subpart B Class B, ICES 003 Class B
  • Power supplies inside: U.S. Department of Energy Level VI
  • NOM certification pending at this revision
Size, weight and mounting
  • 59.5 in (1511 mm) high
  • Weight 55 lb (24.9 kg)
  • Surface or recess mounted, vertically within plus or minus 7 degrees
Run
one drive, one PDU: - 500 ft (152 m) on 12 AWG, not accepted by the Palladiom connector
  • 200 ft (61 m) on 16 AWG
  • 125 ft (38 m) on 18 AWG
Run
two Roller 64 shades: Each up to 30 sq ft (2.75 sq m) plus up to one PDU on one output:
  • 200 ft (61 m) on 12 AWG
  • 75 ft (23 m) on 16 AWG
  • 50 ft (15 m) on 18 AWG
System limits
  • Communication link not over 2000 ft (610 m)
  • Maximum 100 devices per system, each module-equipped sub-plate counting as one
  • Enclosures interconnect through the 3-pin link terminals only

Questions about document 085592

The answers come from Lutron document 085592 and New Way's record of it.

What is Lutron document 085592?

Lutron's seven-page submittal dated 26 November 2018, part number 085592b, for a 59.5 in (1511 mm) cabinet with three sub-plates. Each sub-plate takes two plug-in 5-output modules, six giving thirty outputs for Sivoia QS shades, drapery drives, keypads and accessories.

Which revision of 085592 is current?

Rev B, dated November 2018, is the revision Lutron publishes. New Way checked it against assets.lutron.com on 15 October 2026.

Which roller shades does 085592 cover?

Lutron Sivoia QS roller shades. Lutron document 085592 refers readers to document 369405.

Do the power modules come with the enclosure?

Lutron document 085592 states the power modules do not come with the enclosure: NPM means no power modules.

The unit ships with empty module positions. Each WIN-PS-5CC-R 5-output module is sold separately, singly or as a pack of 12, WIN-PS-5CC-BLK12.

How many shades can a full enclosure power?

Lutron document 085592 gives thirty outputs, each for one drive or up to 8 power draw units.

  • Shared: two Palladiom or Roller 64 up to 30 sq ft (2.75 sq m) each
  • Three of either up to 20 sq ft (1.8 sq m) each
  • Two Roller 100 up to 50 sq ft (4.6 sq m) each

What breaker does each sub-plate need?

Lutron document 085592 requires a 15 A circuit breaker for each 10-output sub-plate, with inrush current as the limit. A 16 A breaker suits some countries; each sub-plate's input is 120 V~ to 240 V~, 50/60 Hz, 10 A.

How far can a shade sit from the enclosure?

Lutron document 085592 gives 500 ft (152 m) on 12 AWG for one shade or drapery drive plus one power draw unit.

  • 16 AWG: 200 ft (61 m), 18 AWG: 125 ft (38 m)
  • Palladiom note: its supplied connector does not take 12 AWG
  • Whole link under 2000 ft (610 m), enclosures joined by the 3-pin link terminals

How big and heavy is the enclosure?

Lutron document 085592 lists the enclosure at 59.5 in (1511 mm) high and 55 lb (24.9 kg).

Surface or recess mounted, vertically within plus or minus 7 degrees. Lutron prints the other cabinet figures on top, front, side and bottom views without naming them.

Ask about 085592

Other Sivoia QS specification submittals

Specification submittals for the same Sivoia QS system:

All 22 Sivoia QS specification submittals

Documents used with 085592

Lutron document 085593 is the 10-output configurable submittal, 085335 the Smart Panel submittal, 085544 and 085329 the single-shade supply submittals. Lutron document 085592 refers to 369405, the QS Link Power Draw Unit submittal, for power draw units.

Revisions of 085592

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
BNov 2018Current. The file on assets.lutron.com. Checked 15 Oct 2026.

Not covered in 085592, and what to read next

Lutron document 085592 gives no module fitting steps, no programming and no power draw unit value per QS device.

  • Power draw units: 369405, the QS Link Power Draw Unit specification submittal
  • Compare: 085593, the 10-output configurable panel specification submittal

Publisher and citation for document 085592

Lutron Electronics Co., Inc. publishes document 085592, Rev B, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 15 October 2026.

Lutron, Sivoia QS and Palladiom are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Sivoia QS?

New Way supplies and installs Lutron Sivoia QS shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.

The form opens with document 085592 filled in.