Lutron 0450007 Rev A (July 2025), Sivoia QS 10 Output Power Panel Power Supply (12 V) Installation Guide. https://assets.lutron.com/a/documents/0450007.pdf, via https://newwaykl.com/resources/lutron/roller-shades/sivoia-qs/lutron-sivoia-qs-10-output-power-panel-power-supply-12-v-installation-guide-0450007/
About document 0450007
Lutron document 0450007, Rev A of July 2025, is the CSPS-P1-10-6 power panel installation guide: input and output ratings, breaker size, mounting load, line voltage and shade wiring, and cable run limits.
What guide 0450007 covers
Lutron document 0450007 has these nine sections. Each link opens the PDF at that page in a new tab.
- Important notes: ratings, codes and environment, opens in a new tab page 1
- Prepare the power panel, opens in a new tab page 1
- Mount the power panel, opens in a new tab page 1
- Connect line voltage, opens in a new tab page 1
- Connect shades, opens in a new tab page 1
- Maximum wire length, opens in a new tab page 1
- Electric shock warnings, opens in a new tab page 1
- Customer assistance and regulatory notices, opens in a new tab page 1
- German, Portuguese, Chinese and Italian text, opens in a new tab page 2
Specifications in 0450007
Lutron document 0450007 prints 26 values in the groups the document uses, each with the document's unit. A row names the catalog codes it applies to. The page link beside each group opens the PDF where the group starts.
Important notes
PDF page 1 of 0450007, opens in a new tab- Input
- 120 V to 240 V AC, 50/60 Hz, 1.5 AModels: CSPS-P1-10-6
- Output
- 12 V DC, 5 A, 60 WModels: CSPS-P1-10-6
- Maximum feed circuit breaker
- 20 AModels: CSPS-P1-10-6
- Wiring and circuit protection
- To national and local electrical codes; some installations need a readily accessible external disconnect device
- Installer
- Qualified electrician
- Ambient operating temperature
- 32 °F to 104 °F (0 °C to 40 °C)Models: CSPS-P1-10-6
- Humidity
- 0 to 90%, non-condensingModels: CSPS-P1-10-6
- Use
- Indoor onlyModels: CSPS-P1-10-6
- Shades
- Honeycomb and roller shades of the Serena and Sivoia QS Triathlon ranges; Sivoia QS Triathlon WIDR roller shades
Prepare the power panel
PDF page 1 of 0450007, opens in a new tab- Front cover screws
- 4Models: CSPS-P1-10-6
- Line voltage shield screw
- 1Models: CSPS-P1-10-6
Mount the power panel
PDF page 1 of 0450007, opens in a new tab- Fastener load rating
- 50 lb (23 kg); fasteners suited to the surface, not providedModels: CSPS-P1-10-6
- Location
- Remains accessible
- Mounting drawing, four values as drawn
- 11.25 in (285.75 mm); 7.50 in (190.5 mm); 1.00 in (25.4 mm); 0.88 in (22.35 mm)Models: CSPS-P1-10-6
Connect line voltage
PDF page 1 of 0450007, opens in a new tab- Supply wire
- 10 to 14 AWG (4.0 to 2.5 mm²)
- Strip length
- 5/16 in (8 mm)
- Terminal screw torque
- 5 in-lb (0.5 N·m)
- Conductors
- Line, Neutral and Ground into the terminal block as drawn
Connect shades
PDF page 1 of 0450007, opens in a new tab- Strip length
- 1/4 in (6 mm)
- Terminal screw torque
- 5 in-lb (0.5 N·m)
- Terminal blocks
- RED for the 12 V DC wire; BLACK for the COM wire
Maximum wire length
PDF page 1 of 0450007, opens in a new tab- 16 AWG (1.5 mm²), distance to shade
- 200 ft (61 m)
- 18 AWG (1.0 mm²), distance to shade
- 125 ft (38 m)
- 20 AWG (0.5 mm²), distance to shade
- 75 ft (23 m)
- Compliance
- FCC Part 15, Class B digital device; Canadian ICES-003, Class BModels: CSPS-P1-10-6
- Languages
- English, French, Spanish, German, Portuguese, Chinese and Italian
Installation walk-through for 0450007
Lutron document 0450007 gives nine steps, in the document's order, after the fixings it lists.
The clearance, the check and the warning under a step are the document's own.
Fixings
- Wall fasteners to suit the surface, rated 50 lb (23 kg), not provided
- A strain relief device for each knockout used, not included
Prepare the panel: remove the front cover
Take out the four front cover screws and lift the cover off the enclosure.
Remove the line voltage shield
Take out the screw that holds the line voltage shield and lift the shield clear of the enclosure. Keep the screw; the shield goes back on it in step 6.
Mount the panel
Choose a position that stays accessible after the build. Fix the panel to the wall through the holes in the back of the enclosure.
Use fasteners suited to the surface and rated for 50 lb (23 kg). Lutron supplies no mounting hardware.
Check: Panel fixed and accessible; fasteners rated for 50 lb (23 kg).
Warning: Indoor use only, at 32 °F to 104 °F (0 °C to 40 °C).
Bring in the line voltage cable
Remove one knockout tab near the input terminal blocks and fit a strain relief device in the hole. Run 10 to 14 AWG (4.0 to 2.5 mm²) supply cable through it to the input terminal blocks.
Clearance: Supply cable 10 to 14 AWG (4.0 to 2.5 mm²)
Warning: Before any wiring at the terminal block, lock the supply breaker OFF; Lutron warns of death or serious injury.
Land Line, Neutral and Ground
Strip 5/16 in (8 mm) from each conductor and insert Line, Neutral and Ground into the terminal block as the drawing shows.
Tighten each terminal screw to 5 in-lb (0.5 N·m) with no insulation inside the block, then tighten the strain relief on the cable.
Clearance: Strip 5/16 in (8 mm); torque 5 in-lb (0.5 N·m)
Check: No insulation inside the terminal block; strain relief tight.
Refit the line voltage shield
Put the shield back over the line voltage wiring and fasten it with its original screw.
Check: Shield in place with all line voltage wiring and connections behind it.
Warning: Never energize or operate the panel without the line voltage shield in place; Lutron warns of death or serious injury.
Bring in the shade cables
Remove knockout tabs from the enclosure bottom as needed and fit a strain relief device in each hole used. Run one shade power cable through each.
Clearance: Panel to shade: 200 ft (61 m) on 16 AWG (1.5 mm²), 125 ft (38 m) on 18 AWG (1.0 mm²). On 20 AWG (0.5 mm²), 75 ft (23 m).
Connect each shade
Strip 1/4 in (6 mm) from each conductor. Put the 12 V DC wire into a RED terminal block and the COM wire into a BLACK terminal block.
Tighten each screw to 5 in-lb (0.5 N·m) with no insulation inside, then tighten the strain relief.
Clearance: Strip 1/4 in (6 mm); torque 5 in-lb (0.5 N·m)
Check: 12 V DC on RED, COM on BLACK; no insulation in the blocks.
Warning: Lutron recommends making the final shade-to-panel connection at the shade, after the panel installation is complete.
Power up and check the shades
After power-up, check the limits and free travel of every shade straight away, so the shades run safely during commissioning.
Check: Every shade reaches its limits and runs freely.
Requirements Lutron states in 0450007
What the guide requires for a Sivoia QS shade before and during installation:
- Ratings
- Input 120 V to 240 V AC, 50/60 Hz, 1.5 A. Output 12 V DC, 5 A, 60 W. Maximum feed circuit breaker 20 A. Lutron requires installation by a qualified electrician to national and local electrical codes. Some installations need an accessible external disconnect.
- Shades it powers
- Honeycomb and roller shades of the Serena and Sivoia QS Triathlon ranges, and Sivoia QS Triathlon WIDR roller shades.
- Environment
- 0 to 90% humidity, non-condensing, at 32 °F to 104 °F (0 °C to 40 °C). Indoor use only.
- Mounting
- Fix through the holes in the enclosure back, in an accessible location
- Fasteners suited to the surface and rated for a 50 lb (23 kg) load
- Mounting hardware is not provided
- Unlabeled drawing marks: 11.25 in (285.75 mm), 7.50 in (190.5 mm)
- Also 1.00 in (25.4 mm) and 0.88 in (22.35 mm)
- Line voltage wiring
- 10 to 14 AWG (4.0 to 2.5 mm²) supply cable through a strain relief
- Strip 5/16 in (8 mm), land Line, Neutral and Ground
- Torque each screw to 5 in-lb (0.5 N·m), no insulation inside the block
- Refit the line voltage shield before energizing
- Shade wiring
- Strip 1/4 in (6 mm)
- 12 V DC to a RED block, COM to a BLACK block
- Each screw to 5 in-lb (0.5 N·m)
- Final connection at the shade, after the panel is installed
- Check shade limits and free travel immediately after power-up
- Maximum wire length
- 16 AWG (1.5 mm²): 200 ft (61 m)
- 18 AWG (1.0 mm²): 125 ft (38 m)
- 20 AWG (0.5 mm²): 75 ft (23 m)
- Safety
- Lock the supply breaker off before wiring the terminal block. Never energize or operate the panel without the line voltage shield in place. Lutron warns of death or serious injury.
- Regulatory
- FCC Part 15 Class B digital device. Class B under Canadian ICES-003.
- Preparation
- Four screws hold the front cover. One screw holds the line voltage shield. The shield lifts out and goes back on its original screw after the line wiring.
- Cable entry
- Line voltage enters through a knockout near the input terminal blocks. Each shade cable enters through a knockout in the bottom of the enclosure. Each knockout takes a strain relief device, not included, tightened once the cable is in.
Questions about document 0450007
The answers come from Lutron document 0450007 and New Way's record of it.
What is Lutron document 0450007?
Lutron's two-page power panel installation guide, printed P/N 0450007 Rev A and 07/2025. The same four steps and drawings print in English, French, Spanish, German, Portuguese, Chinese and Italian.
Which revision of 0450007 is current?
Rev A, dated July 2025, is the revision Lutron publishes. New Way checked it against assets.lutron.com on 15 October 2026.
Which roller shades does 0450007 cover?
Lutron Sivoia QS roller shades.
What supply does the CSPS-P1-10-6 panel need?
Lutron document 0450007 rates the input at 120 V to 240 V AC, 50/60 Hz, 1.5 A.
- Feed breaker of no more than 20 A
- Supply cable 10 to 14 AWG (4.0 to 2.5 mm²), wired by a qualified electrician
- Output 12 V DC, 5 A, 60 W
How far can a shade be from the power panel?
Lutron document 0450007 allows 200 ft (61 m) between the panel and the shade on 16 AWG (1.5 mm²).
- 18 AWG (1.0 mm²): 125 ft (38 m)
- 20 AWG (0.5 mm²): 75 ft (23 m)
How is a shade connected to the panel?
Lutron document 0450007 says to run each shade cable through a strain relief in a bottom knockout and strip 1/4 in (6 mm).
- 12 V DC wire to RED, COM wire to BLACK terminal blocks
- Torque the screws to 5 in-lb (0.5 N·m)
- Make the final connection at the shade, after the panel is installed
Which shades does this panel power?
Lutron document 0450007 powers Serena and Sivoia QS Triathlon honeycomb and roller shades, plus Sivoia QS Triathlon WIDR roller shades.
The panel is for indoor use at 32 °F to 104 °F (0 °C to 40 °C).
Where can the power panel be mounted?
Lutron document 0450007 asks for an accessible location, with the panel fixed through the holes in the enclosure back.
- Fasteners suited to the surface and rated for 50 lb (23 kg)
- Mounting hardware is not supplied
- Indoor use at 32 °F to 104 °F (0 °C to 40 °C)
Other Sivoia QS installation guides
Installation guides for the same Sivoia QS system:
| Document | Drive class | Revision | Date |
|---|---|---|---|
| 045836Serena and Wood Blinds Installation Guide | F | Mar 2025 | |
| 04562030-Output Configurable Power Panel Enclosure, 35V Output Installation Guide | Roller 20 to 300 | B | Jan 2018 |
| 0454114-Group RF Remote Control Installation Guide | Roller 20 to 300 | D | Jan 2015 |
| 045520Basic Wiring and Setup Installation Guide | Roller 20 to 300 | B | Nov 2016 |
Documents used with 0450007
Lutron document 085276 is the specification submittal for the same panel. Lutron document 085283 is the Serena individual plug-in power supply submittal and 045836 the wood blind installation guide.
Revisions of 0450007
This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.
| Revision | Date | Status |
|---|---|---|
| A | Jul 2025 | Current. The file on assets.lutron.com. Checked 15 Oct 2026. |
Not covered in 0450007, and what to read next
Lutron document 0450007 gives no outline dimensions, no specification data beyond the ratings, and no shade-end connection or limit setting.
- Datasheet: 085276, the 10-output power panel specification submittal
- Shade-end connection and limits: the Serena or Triathlon installation guide
Publisher and citation for document 0450007
Lutron Electronics Co., Inc. publishes document 0450007, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 15 October 2026.