Contact Us
Opens in a new tab

085593 · Specification Submittal · Rev B · Dec 2018 · English · PDF, 7 pages, 2.0 MB

Lutron Sivoia QS Configurable Power Panel, 10 Output Specification Submittal (085593, rev B)

Lutron's specification submittal for the QSPS-10PNL-NPM, the Sivoia QS 10-Output Configurable Smart Panel shipped without power modules.

About document 085593

Lutron document 085593, Rev B of December 2018, is the QSPS-10PNL-NPM specification submittal: ratings, breaker rules, wire sizes, dimensions, QS Link wiring rules, thermal dissipation with modules fitted and three application layouts.

What submittal 085593 covers

Lutron document 085593 has these eight sections. Each link opens the PDF at that page in a new tab.

  1. Overview, features and models, opens in a new tab page 1
  2. Specifications, opens in a new tab page 2
  3. Regulatory approvals, environment, performance and warranty, opens in a new tab page 2
  4. Dimensions and mounting, opens in a new tab page 3
  5. Wiring rules, opens in a new tab page 4
  6. Application example: standalone system, opens in a new tab page 5
  7. Application example: GRAFIK Eye QS system, opens in a new tab page 6
  8. Application example: linking multiple Smart Panels, opens in a new tab page 7

Specifications in 085593

Lutron document 085593 prints 58 values in the groups the document uses, each with the document's unit. A row names the catalog codes it applies to. The page link beside each group opens the PDF where the group starts.

Diagnostics and testing
Smart diagnostics check system communication; manual override buttons for shades and lightingModels: QSPS-10PNL-NPM
Fuses
No replaceable fuses needed for overload and miswire protectionModels: QSPS-10PNL-NPM
Enclosure
18 in (457 mm) high, no power modules, ships with empty module placeholders mountedModels: QSPS-10PNL-NPM
Power module, sold separately
Plug-in ready, 5 outputs, compliant with U.S. Department of Energy Efficiency Level VIModels: WIN-PS-5CC-R
Module pack, sold separately
12 x WIN-PS-5CC-RModels: WIN-PS-5CC-BLK12
Outputs when fully populated
10 NEC Class 2 / PELV outputs with 2 modulesModels: QSPS-10PNL
Input
120 V~ to 240 V~, 50/60 Hz, 10 AModels: QSPS-10PNL-NPM
Each output, with WIN-PS-5CC-R installed
35 V DC, 143 mA, 5 WModels: QSPS-10PNL-NPM, WIN-PS-5CC-R
Load per output
1 Sivoia QS shade or drapery drive unit, or as many as 8 QS PDUsModels: QSPS-10PNL-NPM
Wire size
14 AWG to 10 AWG (2.5 mm² to 4.0 mm²), single wire, solid or strandedModels: QSPS-10PNL-NPM
Terminal screw torque
5 in-lbs (0.5 N·m)Models: QSPS-10PNL-NPM
Strip length
5/16 in (8 mm)Models: QSPS-10PNL-NPM
Panels per 15 A circuit breaker
1 maximum (inrush current is the limit); 16 A suits some countriesModels: QSPS-10PNL-NPM
Panels per 20 A circuit breaker
2 maximum (inrush current is the limit)Models: QSPS-10PNL-NPM
Wire size
22 AWG to 12 AWG (0.5 mm² to 4.0 mm²), single wire, solid or stranded; gauge sets the run lengthModels: QSPS-10PNL-NPM
Terminal screw torque
5 in-lbs (0.5 N·m)Models: QSPS-10PNL-NPM
Strip length
1/4 in (6 mm)Models: QSPS-10PNL-NPM
Output terminal blocks
10, 4-conductor, shade power and communicationModels: QSPS-10PNL-NPM
Link terminal blocks
2, 3-conductor, communication pass-throughModels: QSPS-10PNL-NPM
Listings and marks
cULus Listed; IEC compliant (CE marked); NOM certified; contains U.S. Department of Energy Level VI compliant power supplies; RoHS; FCC Part 15 Subpart B Class B; ICES 003 Class BModels: QSPS-10PNL-NPM
Ambient operating temperature
32 °F to 104 °F (0 °C to 40 °C)Models: QSPS-10PNL-NPM
Relative humidity
0% to 90% non-condensingModels: QSPS-10PNL-NPM
Location
Indoor use only; may be installed per NEC Article 300.22(c) in other spaces used for environmental airModels: QSPS-10PNL-NPM
Thermal dissipation with modules, 1 window treatment and keypad per output
20 BTU/hrModels: QSPS-10PNL-NPM
Thermal dissipation with modules, 5 W per output
52 BTU/hrModels: QSPS-10PNL-NPM
Surge protection
Plus or minus 6 kV (ANSI/IEEE C62.41-1991)Models: QSPS-10PNL-NPM
ESD protection
Plus or minus 16 kV air discharge (printed as EIC 61000-4-2)Models: QSPS-10PNL-NPM
Short circuit and miswire protection
Recovers by itself, on each power outputModels: QSPS-10PNL-NPM
Overload and over temperature protection
Recovers by itself, on each outputModels: QSPS-10PNL-NPM
Warranty
Lutron Shading Solutions standard warranty (Window Systems warranty document)Models: QSPS-10PNL-NPM
Weight
15 lb (6.8 kg)Models: QSPS-10PNL-NPM
Mounting
Surface or recess, within the run length the wire gauge allowsModels: QSPS-10PNL-NPM
Knockouts
7/8 in (22 mm) diameter, allModels: QSPS-10PNL-NPM
With cover view
10.88 in (276 mm); 18.00 in (457 mm)Models: QSPS-10PNL-NPM
Side view
4.16 in (106 mm)Models: QSPS-10PNL-NPM
Without cover view
10.38 in (264 mm); 17.50 in (445 mm)Models: QSPS-10PNL-NPM
Bottom view
9.50 in (241 mm)Models: QSPS-10PNL-NPM
Rear view
0.806 in (20.5 mm); 4.75 in (121 mm) twice; 1.75 in (44 mm) twice; 6.00 in (152 mm); 1.45 in (37 mm)Models: QSPS-10PNL-NPM

Wiring Rules, link terminals

PDF page 4 of 085593, opens in a new tab
Wiring class
NEC Class 2 / PELV; local and national codes govern circuit separation and protectionModels: QSPS-10PNL-NPM
COM
12 AWG to 18 AWG (4.0 mm² to 1.0 mm²)Models: QSPS-10PNL-NPM
MUX and MUX
22 AWG (0.5 mm²) twisted and shielded pairModels: QSPS-10PNL-NPM
Total communication link wiring
2000 ft (610 m) maximumModels: QSPS-10PNL-NPM
Devices per Sivoia QS system
100 maximum, counting outputs and link pass-through together; one QSPS-10PNL counts as 1 deviceModels: QSPS-10PNL-NPM
Interconnecting panels
3-pin link terminals only; never the 4-pin output terminalsModels: QSPS-10PNL-NPM

Wiring Rules, output terminals

PDF page 4 of 085593, opens in a new tab
Wiring class
NEC Class 2 / PELV; local and national codes govern circuit separation and protectionModels: QSPS-10PNL-NPM
V+ and COM
12 AWG to 18 AWG (4.0 mm² to 1.0 mm²)Models: QSPS-10PNL-NPM
MUX and MUX
22 AWG (0.5 mm²) twisted and shielded pairModels: QSPS-10PNL-NPM
V+ between outputs
Never connectedModels: QSPS-10PNL-NPM

Wiring Rules, run length per output

PDF page 4 of 085593, opens in a new tab
No shade, up to 8 PDUs
2000 ft (610 m) on 12 AWG (4.0 mm²); 1000 ft (305 m) on 16 AWG (1.5 mm²); 600 ft (183 m) on 18 AWG (1.0 mm²)Models: QSPS-10PNL-NPM
Any 1 shade or drapery drive unit, up to 1 PDU
500 ft (152 m) on 12 AWG, marked with the note that the connector supplied with Palladiom shades does not take 12 AWG wire; 200 ft (61 m) on 16 AWG; 125 ft (38 m) on 18 AWGModels: QSPS-10PNL-NPM
2 Palladiom, each 30 sq ft (2.75 sq m) or less, up to 1 PDU
Not available on 12 AWG (the Palladiom connector does not take 12 AWG); 75 ft (23 m) on 16 AWG; 50 ft (15 m) on 18 AWGModels: QSPS-10PNL-NPM
3 Palladiom, each 20 sq ft (1.8 sq m) or less, up to 1 PDU
Not available on 12 AWG; 75 ft (23 m) on 16 AWG; 50 ft (15 m) on 18 AWGModels: QSPS-10PNL-NPM
2 Sivoia QS roller 64, each 30 sq ft (2.75 sq m) or less, up to 1 PDU
200 ft (61 m) on 12 AWG; 75 ft (23 m) on 16 AWG; 50 ft (15 m) on 18 AWGModels: QSPS-10PNL-NPM
3 Sivoia QS roller 64, each 20 sq ft (1.8 sq m) or less, up to 1 PDU
200 ft (61 m) on 12 AWG; 75 ft (23 m) on 16 AWG; 50 ft (15 m) on 18 AWGModels: QSPS-10PNL-NPM
2 Sivoia QS roller 100, each 50 sq ft (4.6 sq m) or less, up to 1 PDU
200 ft (61 m) on 12 AWG; 75 ft (23 m) on 16 AWG; 50 ft (15 m) on 18 AWGModels: QSPS-10PNL-NPM

Wiring Rules, cable options

PDF page 4 of 085593, opens in a new tab
12 AWG (4.0 mm²) power and communication in one cable
QSH-CBL-L-500 standard; QSH-CBLP-L-500 for plenum installationModels: QSH-CBL-L-500, QSH-CBLP-L-500
16 AWG (1.5 mm²) power and communication in one cable
QSH-CBL-M-500 standard; QSH-CBLP-M-500 for plenum installationModels: QSH-CBL-M-500, QSH-CBLP-M-500
18 AWG (1.0 mm²) power and communication in one cable
GRX-CBL-346S-500 standard; no plenum version printedModels: GRX-CBL-346S-500

Facts Lutron states in 085593

The values Lutron document 085593 states, as published:

Capacity
  • Plug-in ready for two WIN-PS-5CC-R 5-output modules (sold separately)
  • Ten outputs when both are fitted
  • The NPM model ships with empty module positions
Input
120 V~ to 240 V~, 50/60 Hz, 10 A
Each output
35 V DC, 143 mA, 5 W, NEC Class 2 / PELV, with a WIN-PS-5CC-R installed
Devices per output
One Sivoia QS shade or drapery drive unit, or as many as 8 QS power draw units
Panels per breaker
At most 1 panel per 15 A breaker (16 A in some countries) and 2 per 20 A breaker, set by inrush current
Input wiring
  • 14 AWG to 10 AWG (2.5 mm² to 4.0 mm²), solid or stranded
  • Screws torqued to 5 in-lbs (0.5 N·m)
  • Insulation stripped 5/16 in (8 mm)
Output wiring
  • 22 AWG to 12 AWG (0.5 mm² to 4.0 mm²)
  • Screws torqued to 5 in-lbs (0.5 N·m)
  • Insulation stripped 1/4 in (6 mm)
  • Ten 4-conductor output blocks and two 3-conductor link blocks
Conductor sizes at terminals
  • V+ and COM: 12 AWG to 18 AWG (4.0 mm² to 1.0 mm²)
  • MUX pair: 22 AWG (0.5 mm²), twisted and shielded
  • Link terminals take the same COM and MUX sizes
Environment
  • 32 °F to 104 °F (0 °C to 40 °C)
  • 0% to 90% non-condensing humidity, indoor use only
  • Thermal dissipation: 20 BTU/hr with one window treatment and keypad per output
  • Thermal dissipation at 5 W per output: 52 BTU/hr
  • NEC Article 300.22(c): other spaces used for environmental air allowed
Protection
  • Surge: plus or minus 6 kV (ANSI/IEEE C62.41-1991)
  • ESD: plus or minus 16 kV air discharge
  • Short circuit, miswire, overload, over temperature: self-recovering per output
  • No replaceable fuses
Approvals
  • cULus Listed, IEC compliant and CE marked, NOM certified, RoHS
  • FCC Part 15 Subpart B Class B, ICES 003 Class B
  • Power supplies inside: U.S. Department of Energy Level VI
Size and weight
  • Enclosure 18 in (457 mm) high, as stated on page 1
  • With cover view: 18.00 in (457 mm) and 10.88 in (276 mm), the second not named
  • Side view: 4.16 in (106 mm), not named
  • Weight 15 lb (6.8 kg)
  • Knockouts 7/8 in (22 mm) diameter
  • Surface or recess mounted
Run
one drive, one PDU: - 500 ft (152 m) on 12 AWG, not accepted by the Palladiom connector
  • 200 ft (61 m) on 16 AWG
  • 125 ft (38 m) on 18 AWG
Run
two Roller 64 shades: Each up to 30 sq ft (2.75 sq m) plus up to one PDU on one output:
  • 200 ft (61 m) on 12 AWG
  • 75 ft (23 m) on 16 AWG
  • 50 ft (15 m) on 18 AWG
System limits
  • Communication link not over 2000 ft (610 m)
  • Maximum 100 devices per Sivoia QS system, each QSPS-10PNL counting as one
  • Panels interconnect through the 3-pin link terminals only

Questions about document 085593

The answers come from Lutron document 085593 and New Way's record of it.

What is Lutron document 085593?

Lutron's seven-page submittal dated 5 December 2018, part number 085593b, for a panel that takes two plug-in modules. With both fitted it gives ten NEC Class 2 / PELV outputs for Sivoia QS shades, drapery drives, keypads and accessories.

Which revision of 085593 is current?

Rev B, dated December 2018, is the revision Lutron publishes. New Way checked it against assets.lutron.com on 15 October 2026.

Which roller shades does 085593 cover?

Lutron Sivoia QS roller shades. Lutron document 085593 refers readers to document 369405.

What is the difference between QSPS-10PNL-NPM and QSPS-10PNL?

Lutron document 085593 states NPM means no power modules: the enclosure ships with empty module positions. The panel takes two WIN-PS-5CC-R 5-output modules, sold separately, and shows as QSPS-10PNL with both installed.

How many shades can the panel power?

Lutron document 085593 allows one shade or drapery drive, or up to 8 QS power draw units, per output.

  • Shared: two Palladiom or Roller 64 up to 30 sq ft (2.75 sq m) each
  • Three of either up to 20 sq ft (1.8 sq m) each
  • Two Roller 100 up to 50 sq ft (4.6 sq m) each

How many panels can share one breaker?

Lutron document 085593 allows at most 1 panel per 15 A breaker (16 A in some countries) and 2 per 20 A breaker. Inrush current sets the limit; the QSPS-10PNL-NPM input is 120 V~ to 240 V~, 50/60 Hz, 10 A.

How far can a shade sit from the panel?

Lutron document 085593 gives 500 ft (152 m) on 12 AWG for one shade or drapery drive plus one power draw unit.

  • 16 AWG: 200 ft (61 m), 18 AWG: 125 ft (38 m)
  • Palladiom note: its supplied connector does not take 12 AWG
  • Communication link under 2000 ft (610 m)

What wire sizes and torque do the panel terminals take?

Lutron document 085593 gives 14 AWG to 10 AWG (2.5 mm² to 4.0 mm²) at the line input.

  • Output blocks: 22 AWG to 12 AWG (0.5 mm² to 4.0 mm²)
  • Screw torque: 5 in-lbs (0.5 N·m) at input and outputs
  • Strip lengths: 5/16 in (8 mm) at the input, 1/4 in (6 mm) at the outputs
Ask about 085593

Other Sivoia QS specification submittals

Specification submittals for the same Sivoia QS system:

All 22 Sivoia QS specification submittals

Documents used with 085593

Lutron document 085335 is the QSPS-10PNL panel submittal, 085592 the 30-output enclosure submittal, 085544 and 085329 the single-shade supply submittals. Lutron document 085593 refers to 369405, the QS Link Power Draw Unit submittal, for power draw units.

Revisions of 085593

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
BDec 2018Current. The file on assets.lutron.com. Checked 15 Oct 2026.

Not covered in 085593, and what to read next

Lutron document 085593 gives no module fitting steps, no programming and no power draw unit value per QS device.

  • Power draw units: 369405, the QS Link Power Draw Unit specification submittal
  • Compare: 085335, the QSPS-10PNL 10-output Smart Panel specification submittal

Publisher and citation for document 085593

Lutron Electronics Co., Inc. publishes document 085593, Rev B, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 15 October 2026.

Lutron, Sivoia QS and Palladiom are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Sivoia QS?

New Way supplies and installs Lutron Sivoia QS shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.

The form opens with document 085593 filled in.