Lutron document 045625 has these eight sections. Each link opens the PDF at that page in a new tab.

  1. Prepare to install: notes, items and tools, opens in a new tab page 1
  2. Mark the sub-bracket locations, opens in a new tab page 1
  3. Install the sub-brackets, opens in a new tab page 1
  4. Cable entry for ceiling, wall and universal sub-brackets, opens in a new tab page 1
  5. Hang the shade: ceiling, wall and universal mount, opens in a new tab page 1
  6. Level the shade, opens in a new tab page 2
  7. Wire the shade and power up, opens in a new tab page 2
  8. Care and maintenance, opens in a new tab page 2

Specifications in 045625

Lutron document 045625 prints 19 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.

Ambient operating temperature
32 °F to 104 °F (0 °C to 40 °C)
Humidity
0 to 90%, non-condensing
Location
Indoor use only
Wiring and programming reference
Sivoia QS Basic Wiring and Setup, P/N 045520
Hex-head driver
1/4 in (6 mm)

Mark the sub-bracket locations

PDF page 1 of 045625, opens in a new tab
Bracket-to-bracket distance
Tube width + 1.5 in (38 mm)
Spacer blocks for wall mount
May be required to clear the trim (not included)
Ceiling-mount screws per sub-bracket
4
Wall-mount screws per sub-bracket
4
Jamb-mount screws per sub-bracket
3
Combination-mount screws per sub-bracket
As many as the location allows, 4 minimum
Supplied mounting screws
Self-drilling, for solid wood structural members
Universal sub-bracket orientation
Only as shown
People needed
2, one supporting each end
Cable exit
Wall, ceiling or jamb, drive side
Cable left exposed
12 to 18 in (30 to 45 cm)
Ceiling sub-bracket
Clearance hole for ceiling cable entry
Universal sub-bracket
Clearance holes for ceiling and wall cable entry
Idler adjusting screw
Clockwise lowers, counter-clockwise raises the idler end

Installation walk-through for 045625

Lutron document 045625 gives eight steps, in the document's order, after the tools and fixings it lists.

The clearance, the check and the warning under a step are the document's own.

Tools

  • 1/4 in (6 mm) hex-head driver
  • #2 Phillips screwdriver
  • Tape measure
  • Power drill
  • Level

Fixings

  • Self-drilling mounting screws, supplied in each sub-bracket kit
  • Supplied screws: for solid wood structural members
  • Cable tie and anchor (in each sub-bracket kit)
  • Installer-chosen fasteners for other surfaces, able to carry the operating load
  • Spacer blocks for a wall mount where needed (not included)
  1. Prepare

    Read the important notes and check the shades, with shade brackets fitted, and the sub-bracket kits.

    Check: Kits and tools present

  2. Mark the sub-bracket locations

    Mark the positions level and centered over the window, where the screws reach a structural member. Leave clearance so the fabric cannot rub trim, window or top treatment.

    Clearance: Tube width + 1.5 in (38 mm)

    Check: Marks level and centered

  3. Install the sub-brackets

    Fix the sub-brackets at the marks with fasteners suited to the surface.

    Use 4 screws per ceiling or wall sub-bracket, or 4 on a universal sub-bracket for a ceiling or wall mount. A universal sub-bracket takes 3 for a jamb mount and at least 4 for a combination mount.

    Clearance: 4 screws ceiling or wall, 3 jamb, at least 4 combination

    Check: Fasteners carry the operating load

    Warning: Supplied screws suit solid wood structural members; the universal sub-bracket mounts only in the orientation shown

  4. Plan the cable entry

    Bring the cable out on the drive side with 12 to 18 in (30 to 45 cm) exposed. Choose an entry point that does not clash with the sub-bracket.

    Clearance: 12 to 18 in (30 to 45 cm)

    Check: Cable cannot touch the moving fabric

  5. Hang the shade

    With one person at each end, hook the shade brackets into the sub-brackets. On a ceiling mount the top tab goes into the rear hook and the front over the front hook.

    On a wall or universal mount, tilt the shade onto the upper tab and swing down onto the lower tab. Center the shade and fully tighten each securing screw with a hand screwdriver.

    Check: Each bracket passes a careful tug

    Warning: Two people, one supporting each end. 2 ladders or lifts may be needed where the sub-brackets cannot be reached from the floor.

  6. Level the shade

    Lay a bubble level along the fabric roll and turn the idler adjusting screw. Clockwise lowers the idler end, counter-clockwise raises it.

    Check: Fabric roll level

  7. Wire and power up

    Wire the shade and set limits from P/N 045520. Run the shade up and down several times and fix any interference.

    Check: Full travel without interference

  8. Care and maintenance

    No mechanical upkeep is needed. Adjustments and repairs go to the original provider and qualified personnel; dust the fabric in place.

Other warnings Lutron prints in 045625
  • Risk of falling objects: follow every mounting instruction
  • Failing to follow the mounting instructions can cause minor to moderate injury
  • Hanging takes 2 people, one at each end, with ladders or lifts where needed
  • Follow local and national electrical codes
  • Use Lutron controls and power supplies only
  • Keep fixed and remote controls away from children
  • Do not run a shade that shows wear or damage

Requirements Lutron states in 045625

What the guide requires for a Sivoia QS shade before and during installation:

Ambient operating environment
32 °F to 104 °F (0 °C to 40 °C), 0 to 90% humidity non-condensing, indoor use only
Tools required
Power drill, level, tape measure, #2 Phillips screwdriver and a 1/4 in (6 mm) hex-head driver
Bracket-to-bracket distance
Tube width plus 1.5 in (38 mm), level and centered over the window, screws into a structural member that carries the operating load
Screws per sub-bracket, by mount
  • Ceiling or wall sub-bracket: 4
  • Universal sub-bracket, ceiling or wall mount: 4
  • Universal sub-bracket, jamb mount: 3
  • Universal sub-bracket, combination mount: as the location allows, 4 minimum
Supplied screws
Self-drilling, for solid wood structural members
Sub-bracket kits
Ceiling, wall and universal kits each hold sub-brackets, mounting screws and a cable tie and anchor
Cable entry
Out of the wall, ceiling or jamb on the drive side, 12 to 18 in (30 to 45 cm) exposed. Clear of the sub-bracket and the moving fabric
Cable at each sub-bracket
  • Ceiling sub-bracket: beside or below, with a clearance hole for ceiling entry
  • Wall sub-bracket: beside, above or below
  • Universal sub-bracket: ceiling, wall or jamb, holes for ceiling and wall entry
Crew
2 people, one at each end. 2 ladders or lifts where the sub-brackets are out of reach from the floor
Hooking in
ceiling mount: Top tab into the rear hook, front over the front hook
Hooking in
wall, universal: Tilted onto the upper tab, swung down onto the lower tab
Securing
Shade centered, then each bracket's securing screw fully tightened by hand screwdriver through the hook or tab. Each bracket then checked with a careful tug
Leveling
Bubble level along the fabric roll. Idler adjusting screw clockwise to lower, counter-clockwise to raise the idler end

Questions about document 045625

The answers come from Lutron document 045625 and New Way's record of it.

What is Lutron document 045625?

Lutron's six-page wall, ceiling and jamb mount guide for Roller 100, 150 and 300 shades, footer-stamped P/N 045625 Rev A. Pages 3 to 6 of Lutron document 045625 repeat the English pages in French and Spanish.

Which revision of 045625 is current?

Rev A, dated July 2018, is the revision Lutron publishes. New Way checked it against assets.lutron.com on 15 October 2026.

Which roller shades does 045625 cover?

Lutron Sivoia QS roller shades. For related steps Lutron refers readers to document 045520.

How far apart do the sub-brackets go?

Tube width plus 1.5 in (38 mm) bracket to bracket, per Lutron document 045625. Mark the positions level and centered over the window, with the screws in structure.

How many screws does each sub-bracket take?

Lutron document 045625 asks for 4 screws per ceiling or wall sub-bracket. The supplied self-drilling screws suit solid wood structural members.

  • Universal on a ceiling or wall mount: 4
  • Universal on a jamb mount: 3
  • Universal on a combination mount: at least 4, as the location allows

Where should the shade cable come out?

On the drive side of the wall, ceiling or jamb, with 12 to 18 in (30 to 45 cm) exposed, per Lutron document 045625. Keep the cable clear of the sub-bracket and the moving fabric.

How is the shade leveled after hanging?

Lutron document 045625 checks the fabric roll with a bubble level. Turn the idler bracket screw clockwise to lower the idler end, counter-clockwise to raise it.

What clearance does the fabric need from trim?

Lutron document 045625 asks for ample clearance so the fabric cannot rub trim, window, top treatment or other objects. A wall mount may need spacer blocks, not included.

Ask about 045625

Other Sivoia QS installation guides

Installation guides for the same Sivoia QS system:

All 36 Sivoia QS installation guides

Documents used with 045625

Lutron document 045626 is the matching chassis mounting guide for the same shades with a fascia. Lutron documents 045707 and 045211 are the inline and angled coupled shade addenda, and 086106 the Roller 100 specification submittal.

Revisions of 045625

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
AJul 2018Current. The file on assets.lutron.com. Checked 15 Oct 2026.

Not covered in 045625, and what to read next

Lutron document 045625 covers mounting without a fascia and prints no sub-bracket dimensions, load figure or wiring.

  • Wiring and limits: 045520, the Sivoia QS basic wiring and setup guide
  • Fascia ordered: 045626, the Roller 100/150/300 fascia mount chassis guide

Publisher and citation for document 045625

Lutron Electronics Co., Inc. publishes document 045625, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 15 October 2026.

Lutron and Sivoia QS are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Sivoia QS?

New Way supplies and installs Lutron Sivoia QS shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.

The form opens with document 045625 filled in.