  1. Prepare to install: notes, items and tools, opens in a new tab page 1
  2. Mount the optional top back cover, opens in a new tab page 1
  3. Mark the sub-bracket locations, opens in a new tab page 1
  4. Cable entry, opens in a new tab page 1
  5. Install the sub-brackets: wall, ceiling and jamb mount, opens in a new tab page 1
  6. Hang the shade in the sub-brackets, opens in a new tab page 1
  7. Level the shade, opens in a new tab page 1
  8. Wire the shade and power up, opens in a new tab page 2
  9. Mount the fascia, opens in a new tab page 2
  10. Care and maintenance, opens in a new tab page 2

Specifications in 045626

Lutron document 045626 prints 21 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.

Ambient operating temperature
32 °F to 104 °F (0 °C to 40 °C)
Humidity
0 to 90%, non-condensing
Location
Indoor use only
Wiring and programming reference
Sivoia QS Basic Wiring and Setup, P/N 045520
Hex-head driver
1/4 in (6 mm)

Mount the optional top back cover

PDF page 1 of 045626, opens in a new tab
Mounting position
Inside or above the window opening
Fastener pairs
1 pair per 36 in (914 mm) of width
Spacing between fastener pairs
36 in (914 mm) maximum
Screws from the cover ends
3 in (76 mm) minimum

Mark the sub-bracket locations

PDF page 1 of 045626, opens in a new tab
Bracket-to-bracket distance
Tube width + 1.5 in (38 mm)
Spacer blocks for wall mount
May be required to clear the trim (not included)
Cable exit
Wall, ceiling or jamb, drive side
Cable left exposed
12 to 18 in (300 to 450 mm)
Sub-bracket clearance holes
Ceiling and jamb cable entries
Wall mount
4 screws through the rear of the sub-bracket
Ceiling mount
4 screws through the top of the sub-bracket
Jamb mount
4 screws through the top of the sub-bracket
Supplied mounting screws
Self-drilling, for solid wood
People needed
2, one supporting each end
Idler adjusting screw
Clockwise lowers, counter-clockwise raises the idler end
Bottom bar at the upper limit
Below the dotted line in the profile view

Installation walk-through for 045626

Lutron document 045626 gives ten steps, in the document's order, after the tools and fixings it lists.

The clearance, the check and the warning under a step are the document's own.

Tools

  • 1/4 in (6 mm) hex-head driver
  • #2 Phillips screwdriver
  • Level
  • Tape measure
  • Power drill

Fixings

  • Self-drilling mounting screws (supplied, for solid wood)
  • Cable tie and anchor (supplied)
  • Top back cover fasteners in pairs, appropriate for the wall or ceiling
  • Installer-chosen fasteners for other surfaces, able to carry the operating load
  • Spacer blocks for a wall mount where needed (not included)
  1. Prepare

    Read the important notes and check the shades, sub-brackets, screws, fascia and any top back cover.

    Check: Parts and tools present

  2. Mount the optional top back cover

    Fix the cover inside or above the opening with fastener pairs into the wall or ceiling. Pre-drill where possible, do not over-tighten, and shim the cover true.

    Clearance: 1 pair per 36 in (914 mm) of width; screws at least 3 in (76 mm) from the cover ends

    Check: Cover level, straight and untwisted

    Warning: Screws too near the cover ends foul the shade brackets

  3. Mark the sub-bracket locations

    Mark the sub-brackets on the surface or top back cover, level and centered over the window. Put them over structure, with clearance for the fabric.

    Clearance: Tube width + 1.5 in (38 mm)

    Check: Marks level and centered

  4. Plan the cable entry

    Bring the cable out on the drive side through the sub-bracket's ceiling or jamb clearance holes. Or bring it out beside or below the sub-bracket, without clashing with it.

    Clearance: 12 to 18 in (300 to 450 mm) exposed

    Check: Cable cannot touch the moving fabric

  5. Install the sub-brackets

    Fix each sub-bracket at its marks with 4 screws. Drive them through the rear for a wall mount, or through the top for a ceiling or jamb mount.

    Clearance: 4 screws per sub-bracket

    Check: Fasteners suit the surface and load

    Warning: Supplied screws suit solid wood only

  6. Hang the shade

    With one person at each end, insert the bracket tabs into the rear hangers. Lift the front so the front hooks ride over the front hangers.

    Center the shade and tighten each securing screw with the Phillips screwdriver.

    Check: Each end passes a careful tug

  7. Level the shade

    Check the fabric roll with a bubble level; turn the idler adjusting screw clockwise to lower or counter-clockwise to raise.

    Check: Fabric roll level

  8. Wire and power up

    Wire the shade and set limits from P/N 045520. Run it up and down several times and fix any interference.

    Check: Full travel without interference

  9. Mount the fascia

    Hook the fascia's top lip on the upper hooks and check full engagement. Swing the bottom under the shade and snap the triangular lip behind the lower tabs.

    Center the fascia and run the shade to both limits several times.

    Check: Fabric touches neither fascia nor anything else

    Warning: The upper limit must keep the bottom bar out of the sub-brackets

  10. Care and maintenance

    No mechanical upkeep is needed. Adjustments and repairs go to the original provider and qualified personnel; dust the fabric in place.

Other warnings Lutron prints in 045626
  • Risk of falling objects: follow every mounting instruction
  • Failing to follow the mounting instructions can cause minor to moderate injury
  • Mount the system and top back cover to blocking or other structural material
  • Hanging takes 2 people, one at each end, with ladders or lifts where needed
  • Follow local and national electrical codes
  • Use Lutron controls and power supplies only
  • Keep fixed and remote controls away from children
  • Do not run a shade that shows wear or damage

Count the top back cover fastener pairs from 045626

Lutron document 045626 spaces the fastener pairs along the top back cover: one at each end, at least 3 in (76 mm) in from the end. The rest sit at most 36 in (914 mm) apart.

Enter the top back cover width to count the fastener pairs along the top back cover.

From Lutron document 045626, page 1; confirm against the PDF before you drill.

Requirements Lutron states in 045626

What the guide requires for a Sivoia QS shade before and during installation:

Ambient operating environment
32 °F to 104 °F (0 °C to 40 °C), 0 to 90% humidity non-condensing, indoor use only
Tools required
Power drill, tape measure, level, #2 Phillips screwdriver and a 1/4 in (6 mm) hex-head driver
Top back cover fixing
One fastener pair per 36 in (914 mm) of width, at least 3 in (76 mm) from the cover ends, shimmed level and untwisted
Bracket-to-bracket distance
Tube width plus 1.5 in (38 mm), marked on the surface or the top back cover, level and centered, into structure
Cable entry
Drive side, 12 to 18 in (300 to 450 mm) exposed, through the sub-bracket's ceiling or jamb clearance holes or beside or below it
Screws per sub-bracket
4, through the rear for a wall mount and through the top for ceiling and jamb mounts. Supplied self-drilling screws suit solid wood
Hanging the shade
Two people. Tabs into the rear hangers, front hooks over the front hangers, securing screws tightened and tug-checked
Leveling
Bubble level along the fabric roll. Idler adjusting screw clockwise to lower, counter-clockwise to raise
Fitting the fascia
Top lip on the upper hooks, bottom swung under the shade, triangular lip snapped behind the lower tabs
Upper limit with a fascia
Set so the bottom bar stays below the profile view's dotted line and is not drawn into the sub-brackets

Questions about document 045626

The answers come from Lutron document 045626 and New Way's record of it.

What is Lutron document 045626?

Lutron's eight-page fascia mount guide for Roller 100, 150 and 300 shades, footer-stamped P/N 045626 Rev A. Pages 3 to 8 of Lutron document 045626 repeat the English pages in French, Spanish and Portuguese.

Which revision of 045626 is current?

Rev A is the revision Lutron publishes. New Way checked it against assets.lutron.com on 15 October 2026.

Which roller shades does 045626 cover?

Lutron Sivoia QS roller shades. For related steps Lutron refers readers to document 045520.

How is the optional top back cover fixed?

One fastener pair per 36 in (914 mm) of cover width, per Lutron document 045626. Every screw sits at least 3 in (76 mm) from the cover ends.

How many screws does each sub-bracket take, and where?

Lutron document 045626 uses 4 screws per sub-bracket. Wall mounts take them through the rear, ceiling and jamb mounts through the top.

How does the fascia go on?

Lutron document 045626 hooks the fascia's top lip on the upper hooks. The triangular lip then snaps behind the lower tabs.

How far apart are the sub-brackets and how much cable is left?

Tube width plus 1.5 in (38 mm) between the sub-brackets, per Lutron document 045626. Lutron leaves 12 to 18 in (300 to 450 mm) of cable exposed on the drive side.

Can the shade be mounted inside or outside the opening?

Lutron document 045626 shows both outside and inside mounts, with the top back cover inside or above the opening.

Ask about 045626

Other Sivoia QS installation guides

Installation guides for the same Sivoia QS system:

All 36 Sivoia QS installation guides

Documents used with 045626

Lutron document 045625 is the matching guide for the same shades without a fascia. Lutron document 086106 is the Roller 100 specification submittal, and 045707 and 045211 are the coupled shade addenda.

Revisions of 045626

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
ANot statedCurrent. The file on assets.lutron.com. Checked 15 Oct 2026.

Not covered in 045626, and what to read next

Lutron document 045626 prints no fascia or bracket dimensions and no wiring.

  • Wiring and limits: 045520, the Sivoia QS basic wiring and setup guide
  • No fascia ordered: 045625, the Roller 100/150/300 wall, ceiling and jamb guide

Publisher and citation for document 045626

Lutron Electronics Co., Inc. publishes document 045626, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 15 October 2026.

Lutron and Sivoia QS are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Sivoia QS?

New Way supplies and installs Lutron Sivoia QS shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.