About document 045658

Lutron document 045658, Rev A of July 2018, is the Palladiom installation planning and template guide: the three templates, their gauges, the wire housing hole, the bracket pilot holes and the tape measure check.

What guide 045658 covers

Lutron document 045658 has these five sections. Each link opens the PDF at that page in a new tab.

  1. Overview: what the three templates are for, opens in a new tab page 1
  2. Wall mount: wire housing, then bracket screws, opens in a new tab page 1
  3. Using the wall mount template, opens in a new tab page 1
  4. Using the ceiling mount template, opens in a new tab page 2
  5. Using the jamb mount template, opens in a new tab page 2

Specifications in 045658

Lutron document 045658 prints 21 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.

Wire housing
3/4 in (19 mm) x 3 in (76 mm)
Recommended bit for the wire housing
3/4 in (19 mm) Forstner bit
Bracket mounting pilot hole size
1/8 in (3 mm) when using the #10 mounting screws provided with the shade
Templates
Wall Mount, Ceiling Mount, Jamb Mount
First use of the template
Early phases of construction: wire box hole location
Second use of the template
Finished wall: pilot hole locations for the bracket mounting screws
Cable
Power / QS Link cable, joined to the shade wire harness and tucked into the wire housing
Template labels
A fabric edge locator; B bracket footprint; C jamb offset gauge; D jamb offset thumbscrews; E height gauge; F height gauge stops; G height gauge thumbscrews; H tape measure anchor; J tape measure accuracy check
Height gauge reference
Stops against the top of the window opening
Tape measure check notches
10 in (254 mm), right edge to right edge and left edge to left edge
Template labels
A fabric edge locator; B bracket footprint; C bracket/wall gauge; D bracket/wall gauge thumbscrews; E tape measure anchor; F tape measure accuracy check
Bracket/wall gauge
Sets the bracket footprint at the chosen distance from the wall
Tape measure check notches
10 in (254 mm), right edge to right edge and left edge to left edge
Template labels
A bracket footprint; B bracket height gauge; C height gauge thumbscrews; D window distance gauge; E window distance gauge thumbscrews; F tape measure anchor; G tape measure accuracy check
Bracket height reference
Top of the window opening
Bracket depth reference
Window glass
Opposite jamb
Same measurements transferred
Tape measure check notches
10 in (254 mm), right edge to right edge and left edge to left edge
Part number and revision
P/N 045658 Rev. A
Footer date
July 2018
Further information
Lutron.com/PalladiomShades

Installation walk-through for 045658

Lutron document 045658 gives 13 steps, in the document's order, after the tools and fixings it lists.

The clearance, the check and the warning under a step are the document's own.

Tools

  • Palladiom wall, ceiling or jamb mount template
  • 3/4 in (19 mm) Forstner bit, recommended
  • Tape measure

Fixings

  • Wire housing, 3/4 in (19 mm) x 3 in (76 mm)
  • #10 mounting screws provided with the shade, in 1/8 in (3 mm) pilot holes
  1. Position the template and mark the wire housing

    Early in construction, set the template at the window opening; the guide shows the wall mount version. Use its gauges to find the wire housing location and mark it.

    Check: Wire housing location marked for drilling

  2. Drill for the wire housing

    Drill at the marked location for the wire housing, with the 3/4 in (19 mm) Forstner bit Lutron recommends.

    Clearance: Wire housing 3/4 in (19 mm) x 3 in (76 mm)

  3. Fit the wire housing and pull the cable

    Install the wire housing and pull the power or QS Link cable through it, ready for the bracket later.

    Check: Cable pulled through the installed housing

  4. Mark the bracket screws on the finished wall

    When the wall is finished, put the template back in place and mark the bracket mounting screw locations.

    Clearance: Pilot holes 1/8 in (3 mm) for the #10 mounting screws provided with the shade

    Check: Screw locations marked

  5. Mount the bracket over the housing

    As the bracket goes on, the shade wire harness runs through it and joins the power or QS Link cable. The joined cables are pushed into the wire housing so the bracket hides all of the wiring.

    Check: No wiring visible around the bracket

  6. Wall mount: set left and right position

    Hold the template against the mounting surface. To place the bracket from a chosen fabric edge, line up the fabric edge locator A.

    To find the fabric edge from a chosen bracket position, line up the bracket footprint B. Either way, set the jamb offset with gauge C and tighten thumbscrews D.

    Check: Jamb offset thumbscrews D tight

  7. Wall mount: set the bracket height

    Keeping the template in place, set the bracket footprint B at the height wanted on the wall. Bring the height gauge E round until its stops F rest on the window opening top, then tighten thumbscrews G.

    Check: Stops F on the top of the window opening; thumbscrews G tight

  8. Preset the gauges and check the tape measure

    To work from set measurements, preset the gauges with the tape measure anchoring slot. The slot sits at the bracket center, H on the wall mount template.

    Check the tape against the notches at the template edge, exactly 10 in (254 mm) apart edge to edge. The ceiling and jamb templates carry the same anchor and notches.

    Clearance: 10 in (254 mm) between matching notch edges

    Check: Tape reads 10 in (254 mm) across the notches

  9. Ceiling mount: set left and right position

    Hold the ceiling mount template against the mounting surface.

    Line up the fabric edge locator A when the fabric edge is fixed. Line up the bracket footprint B instead when the bracket position is fixed.

  10. Ceiling mount: set the wall distance

    With the template still in place, set the bracket footprint B at the distance wanted from the wall. Set that distance on the bracket/wall gauge C and tighten thumbscrews D.

    Check: Thumbscrews D tight

  11. Jamb mount: set the bracket height

    Hold the jamb mount template against the mounting surface. Use the bracket height gauge B to set the distance to the window opening top, then tighten thumbscrews C.

    Check: Thumbscrews C tight

  12. Jamb mount: set the bracket depth

    With the template against the surface, use the window distance gauge D to set the distance to the glass. Tighten thumbscrews E.

    Check: Thumbscrews E tight

  13. Jamb mount: transfer to the opposite jamb

    Carry the same height and depth settings across to the opposite jamb so both brackets match.

    Check: Both jambs marked from the same settings

Requirements Lutron states in 045658

What the guide requires for a Palladiom shade before and during installation:

Wire housing
3/4 in (19 mm) by 3 in (76 mm), with a 3/4 in (19 mm) Forstner bit recommended
Bracket pilot holes
1/8 in (3 mm) when using the #10 mounting screws supplied with the shade
When the template is used
Twice: early in construction for the wire housing hole, then on the finished wall for the bracket screw locations
Cable concealment
The bracket hides all wiring
  • The shade wire harness passes through the bracket
  • The harness connects to the power or QS Link cable
  • The joined cables tuck into the wire housing
Tape measure check
Notches at the top edge of each template sit exactly 10 in (254 mm) apart, edge to edge, to check the tape before marking
Wall mount template gauges
  • Fabric edge locator
  • Bracket footprint
  • Jamb offset gauge
  • Height gauge, with stops resting on the top of the window opening
Ceiling mount template gauges
  • Fabric edge locator
  • Bracket footprint
  • Bracket-to-wall gauge, setting the bracket distance from the wall
Jamb mount template gauges
  • Bracket height gauge to the top of the window opening
  • Window distance gauge to the glass
  • Settings then transferred to the opposite jamb
Purpose of the guide
A reference for the three templates that supplements Lutron's Palladiom Shades training program
Presetting the gauges
For set measurements, the gauges preset with the tape measure anchoring slot at each template's bracket center
Overview sequence
Shown on the wall mount
  • Template at the window opening to mark the wire housing
  • Location drilled, housing installed, cable pulled
  • Template re-applied on the finished wall for the screws
  • Bracket fitted with the cables tucked into the housing

Questions about document 045658

The answers come from Lutron document 045658 and New Way's record of it.

What is Lutron document 045658?

Lutron's six-page planning and template guide, dated July 2018, in English, French and Spanish, two pages each.

Which revision of 045658 is current?

Rev A, dated July 2018, is the revision Lutron publishes. New Way checked it against assets.lutron.com on 15 October 2026.

Which roller shades does 045658 cover?

Lutron Palladiom roller shades.

What size is the Palladiom wire housing, and which bit is recommended?

Lutron document 045658 gives the wire housing as 3/4 in (19 mm) x 3 in (76 mm). Lutron recommends a 3/4 in (19 mm) Forstner bit.

Does the guide cover ceiling and jamb mounts too?

Lutron document 045658 covers all three Palladiom templates: Wall Mount, Ceiling Mount and Jamb Mount. Lutron gives each template its own lettered gauges and steps, with the wall mount used for the overview sequence.

What pilot hole do the Palladiom bracket screws take?

Lutron document 045658 states a 1/8 in (3 mm) pilot hole when the #10 mounting screws supplied with the shade are used.

How does the jamb mount template set the bracket position?

Lutron document 045658 sets the bracket height gauge to the top of the window opening.

The window distance gauge then sets the distance to the glass. Once both thumbscrews are tight, the same settings transfer to the opposite jamb.

At what stage of construction are the Palladiom templates used?

Lutron document 045658 says the templates mark the wire box hole in the early phases of construction.

The bracket conceals the cable later. The template goes on again, on the finished wall, to mark the bracket screw locations.

Ask about 045658

Other Palladiom installation guides

Installation guides for the same Palladiom system:

All 10 Palladiom installation guides

Documents used with 045658

Lutron document 045658 cites no other document number and points readers to Lutron.com/PalladiomShades for more information. Lutron documents 045779 and 085650 are the spackle ring and plug guide and the wire housing detail CAD drawing.

Revisions of 045658

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
AJul 2018Current. The file on assets.lutron.com. Checked 15 Oct 2026.

Not covered in 045658, and what to read next

Lutron document 045658 does not cover wiring, fixing the brackets, hanging the shade or setting limits.

  • Shade and brackets: 045969, the Palladiom chassis installation and setup guide
  • The housing itself: 045770, the wire housing installation guide

Publisher and citation for document 045658

Lutron Electronics Co., Inc. publishes document 045658, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 15 October 2026.

Lutron and Palladiom are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Palladiom?

New Way supplies and installs Lutron Palladiom shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.

The form opens with document 045658 filled in.