Contact Us
Opens in a new tab

045770 · Installation Guide · Rev A · May 2019 · English, French, Spanish, German, Italian, Dutch · PDF, 6 pages, 0.7 MB

Lutron Palladiom Roller Shades Installation Guide: Wire Housing (045770, rev A)

Lutron's installation guide for the Palladiom wire housing WIN-WM-BOX-10, where a wired roller shade's power wire leaves the wall.

About document 045770

Lutron document 045770, Rev A of May 2019, is the wire housing installation guide: one drawing sheet in six languages with housing dimensions, recess depths, tools, wall labels and four numbered steps.

What guide 045770 covers

Lutron document 045770 has these five sections, all on page 1.

  1. NEC Class 2 / PELV wiring notice
  2. Wire housing component and package quantity
  3. Housing dimensions and recess depths
  4. Tools needed
  5. Four installation steps, framed and finished wall

Specifications in 045770

Lutron document 045770 prints ten values in the groups the document uses, each with the document's unit. A row names the catalog codes it applies to. The page link beside each group opens the PDF where the group starts.

Wiring class
NEC Class 2 / PELV onlyModels: WIN-WM-BOX-10
Package quantity
10Models: WIN-WM-BOX-10
Drill bit
3/4 in (19 mm) Forstner bit, in a power drill
Driver bit
Phillips
Approximate depth
1/4 in (6 mm)Models: WIN-WM-BOX-10
Minimum depth
3 in (76 mm)Models: WIN-WM-BOX-10
Dimension as printed, unlabeled
0.78 in (20 mm)Models: WIN-WM-BOX-10
Dimension as printed, unlabeled
0.62 in (16 mm)Models: WIN-WM-BOX-10
Dimension as printed, unlabeled
1.20 in (30.5 mm)Models: WIN-WM-BOX-10
Dimension as printed, unlabeled
3.50 in (89 mm)Models: WIN-WM-BOX-10

Requirements Lutron states in 045770

What the guide requires for a Palladiom shade before and during installation:

Wiring class
For NEC Class 2 / PELV wiring only
Part and pack
WIN-WM-BOX-10 wire housing, package of 10
Recess depths
Approximate depth 1/4 in (6 mm) and minimum depth 3 in (76 mm), printed as labels on the installation drawings
Tools
Power drill with a 3/4 in (19 mm) Forstner bit, plus a Phillips driver bit
Printed dimensions
Four figures beside the housing drawing, none tied to a label in the text
  • 0.62 in (16 mm)
  • 0.78 in (20 mm)
  • 1.20 in (30.5 mm)
  • 3.50 in (89 mm)
Wall types
Framed wall and finished wall labeled on the drawing, with the shade power wire labeled once
Steps
Four numbered steps drawn, with no written instructions
Issue
Revision A, dated May 2019 on every page
Languages
English, French, Spanish, German, Italian and Dutch, one language per page

Questions about document 045770

The answers come from Lutron document 045770 and New Way's record of it.

What is Lutron document 045770?

Lutron's six-page wire housing installation drawing, dated May 2019 on every page under revision A, one language per page.

Which revision of 045770 is current?

Rev A, dated May 2019, is the revision Lutron publishes. New Way checked it against assets.lutron.com on 15 October 2026.

Which roller shades does 045770 cover?

Lutron Palladiom roller shades.

What wiring is the Palladiom wire housing rated for?

Lutron document 045770 marks the wire management system for NEC Class 2 / PELV wiring only.

What hole does the housing need?

A 3/4 in (19 mm) Forstner bit in a power drill, per Lutron document 045770, which also lists a Phillips driver bit.

  • Approximate depth: 1/4 in (6 mm)
  • Minimum depth: 3 in (76 mm)

How many housings come in a pack?

Lutron document 045770 lists WIN-WM-BOX-10 as a package of 10 wire housings.

Does the guide cover both finished and framed walls?

Lutron document 045770 labels both a framed wall and a finished wall on its installation drawing and numbers four steps. The steps are drawings only, with no written instructions.

What do the printed dimensions refer to?

Lutron document 045770 prints four figures beside the housing drawing, and the text ties none of them to a feature.

  • 0.62 in (16 mm) and 0.78 in (20 mm)
  • 1.20 in (30.5 mm) and 3.50 in (89 mm)
Ask about 045770

Other Palladiom installation guides

Installation guides for the same Palladiom system:

All 10 Palladiom installation guides

Documents used with 045770

Lutron document 045770 sits with the Palladiom accessory sheets 045779, 045685, 045686 and 045777, all for the wired shade. The Palladiom Wire-Free shade has its own installation guide, 045913, and specification submittal, 085708.

Revisions of 045770

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
AMay 2019Current. The file on assets.lutron.com. Checked 15 Oct 2026.

Not covered in 045770, and what to read next

Lutron document 045770 covers the wire housing alone, with no shade mounting, wiring run, power supply data or written steps.

  • The shade itself: 045969, the wired Palladiom chassis setup guide
  • Spackle ring and plug: 045779, the wire concealment guide

Publisher and citation for document 045770

Lutron Electronics Co., Inc. publishes document 045770, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 15 October 2026.

Lutron and Palladiom are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Palladiom?

New Way supplies and installs Lutron Palladiom shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.

The form opens with document 045770 filled in.