About document 085632

Lutron drawing 085632, Rev C, is the two-page butt and pass corner detail: auxiliary views at 1/4 scale, bracket top views at 1/2, tube and roll-up, reverse roll light gaps, clearances and the measurement deduction.

What drawing 085632 covers

Lutron document 085632 has these twelve sections. Each link opens the PDF at that page in a new tab.

  1. Sheet header: butt and pass typical details, opens in a new tab page 1
  2. Auxiliary views, ceiling bracket shown, opens in a new tab page 1
  3. Tube and maximum roll-up, opens in a new tab page 1
  4. Reverse roll light gap, lower limit, opens in a new tab page 1
  5. Reverse roll light gap, upper limit, opens in a new tab page 1
  6. Pointer to the section drawing, opens in a new tab page 1
  7. Clearance note and 90° corner basis, opens in a new tab page 1
  8. Sheet header: butt and pass bracket details, opens in a new tab page 2
  9. Top views of the bracket details, opens in a new tab page 2
  10. Minimum recommended clearances, opens in a new tab page 2
  11. Measurement deduction, opens in a new tab page 2
  12. Title blocks: drawing number, scale, page and revision, opens in a new tab page 1

Specifications in 085632

Lutron document 085632 prints 19 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.

Tube
2.00 in (51 mm)
Max rollup
3.00 in (77 mm)
Reverse roll light gap, lower limit
1.50 in (38 mm) typical
Reverse roll light gap at max roll, upper limit
1.00 in (25 mm) typical
Bracket shown
Ceiling bracket
Surface marked
Wall
System height and detailed mounting requirement
Refer to the section drawing
Scale of one view
1/8
Max rollup
3.00 in (76 mm)
Measurement deduction
4.00 in (102 mm)
Minimum recommended clearance
0.50 in (13 mm), three callouts
Labels
Ceiling; wall
Corner basis
Minimum recommended deductions based on a 90° corner
Clearance note
A shade installed as the factory supplies it has the clearances it needs to operate; the master technician keeps them after installation
Drawing title
Palladiom shade butt and pass installation
Drawing number
085632
Page 1
Auxiliary views, scale 1/4
Page 2
Top views, scale 1/2
Revision
C

Facts Lutron states in 085632

The values Lutron document 085632 states, as published:

What the drawing shows
Two Palladiom shades meeting at a corner in a butt and pass arrangement
Pages
Page 1: auxiliary views, a ceiling bracket shown and the wall marked. Page 2: top views of the bracket details.
Corner basis
Lutron bases the minimum recommended deductions on a 90° corner
Light gap, lower limit
1.50 in (38 mm) typical, reverse roll
Light gap, upper limit
1.00 in (25 mm) typical, reverse roll at maximum roll
Maximum roll-up
3.00 in, printed as 77 mm on page 1 and 76 mm on page 2
Tube
2.00 in (51 mm)
Measurement deduction
4.00 in (102 mm)
Minimum recommended clearance
0.50 in (13 mm), printed three times on the top views
System height
Not printed: Lutron refers the reader to the section drawing for the system height and the detailed mounting requirement
Clearances
A shade installed as the factory supplies it has the clearances it needs to operate. The master technician keeps them after installation.
Title blocks
Page 1 at scale 1/4 with one view at 1/8, page 2 at scale 1/2
Revision
C on both pages, no date printed
File formats
PDF, DWG and DXF

Questions about document 085632

The answers come from Lutron document 085632 and New Way's record of it.

What is Lutron document 085632?

Lutron's application detail for two Palladiom roller shades meeting at a corner in a butt and pass arrangement. Lutron drawing 085632, Rev C, is the two-page butt and pass corner detail: auxiliary views at 1/4 scale, bracket top views at 1/2, tube and roll-up, reverse roll light gaps, clearances and the measurement deduction.

Which revision of 085632 is current?

Rev C is the revision Lutron publishes. New Way checked it against assets.lutron.com on 16 October 2026.

Which roller shades does 085632 cover?

Lutron Palladiom roller shades.

How much do I deduct where two shades meet at a corner?

Lutron drawing 085632 prints a 4.00 in (102 mm) measurement deduction on the top views of the butt and pass bracket details. Lutron bases the minimum recommended deductions on a 90° corner.

Does the corner detail apply to corners other than 90°?

Lutron drawing 085632 bases the minimum recommended deductions on a 90° corner. Lutron's sheet gives no deduction for any other corner angle.

What light gap is left at the corner?

Lutron drawing 085632 dimensions a reverse roll light gap of 1.50 in (38 mm) typical at the lower limit. Lutron gives 1.00 in (25 mm) typical as the reverse roll light gap at maximum roll, the upper limit.

What roll size does the corner detail assume?

Lutron drawing 085632 prints a 2.00 in (51 mm) tube and a 3.00 in maximum roll-up. Lutron gives the roll-up as 77 mm on page 1 and 76 mm on page 2.

What clearance does Lutron recommend on the bracket details?

Lutron drawing 085632 prints a minimum recommended clearance of 0.50 in (13 mm) three times on the top views. Lutron's sheet does not say in words which surface each clearance is taken from; the top views show it.

Ask about 085632

Other Palladiom CAD drawings

CAD drawings for the same Palladiom system:

All 38 Palladiom CAD drawings

Documents used with 085632

Lutron drawings 085633 and 085736 are the corner to corner and wire-free butt and pass details; 085560 the specification submittal. Lutron's 085585, 085604 and 085582 are the ceiling mount views, 085587 the end bracket detail, 045658 the planning guide.

Revisions of 085632

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
CNot statedCurrent. The file on assets.lutron.com. Checked 16 Oct 2026.

Not covered in 085632, and what to read next

Lutron drawing 085632 gives light gaps, roll size, clearances and deduction only, no system height, fixing sizes or mounting steps.

  • System height: 085582, the wired Palladiom ceiling mount section view
  • Mounting steps: 045658, the wired shading system planning and template guide

Publisher and citation for document 085632

Lutron Electronics Co., Inc. publishes document 085632, Rev C, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 16 October 2026.

Lutron and Palladiom are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Palladiom?

New Way supplies and installs Lutron Palladiom shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.

The form opens with document 085632 filled in.