You searched and this document matched it.
See all results045129 · Application Note · Rev A · English · PDF, 4 pages, 0.7 MB
Lutron Sivoia QS Application Note: Retrofitting an Existing Drapery System with the Enhanced EDU (045129)
Lutron's application note for fitting the enhanced Sivoia QED drapery electronic drive unit (EDU) to an installed track.
Lutron 045129 Rev A, Sivoia QS Application Note: Retrofitting an Existing Drapery System with the Enhanced EDU. https://assets.lutron.com/a/documents/apps_note_13.pdf, via https://newwaykl.com/resources/lutron/roller-shades/sivoia-qs/lutron-sivoia-qs-application-note-045129/
About document 045129
Lutron document 045129, Rev A of 2007, is the retrofit procedure for the enhanced EDU: old EDU and lower rail box out, new pulley shaft, bearing and rail box in, then back to document 045121.
What note 045129 covers
Lutron document 045129 has these seven sections. Each link opens the PDF at that page in a new tab.
- Overview, opens in a new tab page 1
- Power down, remove track and old EDU, opens in a new tab page 1
- Remove the lower rail box, opens in a new tab page 2
- Insert the new pulley shaft, opens in a new tab page 2
- Adjusting belt tension, opens in a new tab page 3
- Fit the new bearing and lower rail box, opens in a new tab page 4
- Re-install track, new EDU, terminal block, limits, opens in a new tab page 4
Specifications in 045129
Lutron document 045129 prints 13 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.
Instructions
PDF pages 1 and 2 of 045129, opens in a new tab- System
- Existing Sivoia QED drapery track system
- Drive fitted
- Enhanced Sivoia QED drapery electronic drive unit (EDU)
- Screws holding the EDU to the lower rail box
- 3
- Lower rail box side removed with
- Small flat-head screwdriver
- Screws holding the lower rail box to the upper rail box
- 4
- New pulley shaft
- Through the plastic pulley into the upper rail box, fully seated
Adjusting belt tension
PDF page 3 of 045129, opens in a new tab- Set screw tool
- 5/64 in hex wrench
- Reference for the original tension
- Mark of the upper rail box position on the track
Instructions
PDF page 4 of 045129, opens in a new tab- New bearing
- Onto the new pulley shaft, before the new lower rail box
- Lower rail box screws
- 4, tightened until snug, not over-tightened
- Terminal block
- 7-pin, at the transformer, wall control or power panel; replaced with the new 7-pin block
- Steps referred to P/N 045-121
- Mount the new EDU; replace the terminal block; set limits from the EDU
- Part number and revision
- P/N 045-129 Rev A, © 2007
Installation walk-through for 045129
Lutron document 045129 gives twelve steps, in the document's order, after the tools and fixings it lists.
The clearance, the check and the warning under a step are the document's own.
Tools
- Small flat-head screwdriver
- 5/64 in hex wrench (no metric size printed)
Fixings
- 3 screws holding the EDU to the lower rail box (removed)
- 4 screws, lower rail box to upper rail box (removed)
- The same 4 screws refitted to the new lower rail box
- Set screw on the upper rail box (loosened and retightened)
- New parts: pulley shaft, bearing, lower rail box, 7-pin terminal block
- New part: the enhanced EDU
Power down
Unplug the existing drive unit at the EDU. Remove power from the transformer that feeds the EDU.
Check: The transformer feeding the EDU is off
Take the track down
Remove the drapery track from the ceiling or the wall so the drive end can be worked on.
Remove the old EDU
Take out the three screws in the lower rail box that hold the EDU. Lift the EDU away.
Open the lower rail box
With a small flat-head screwdriver, remove the lower rail box side that held the three EDU screw heads.
Remove the lower rail box
Take out the four screws that hold the lower rail box to the upper rail box. Remove the lower rail box.
Slacken the belt (recommended)
Lutron recommends easing the belt tension so the new shaft goes in more easily. Mark on the track where the upper rail box sits now.
Loosen the set screw with the 5/64 in hex wrench. Slide the upper rail box assembly to slacken the belt.
Check: The present position of the upper rail box is marked on the track before the set screw is loosened
Fit the new pulley shaft
Push the new pulley shaft through the plastic pulley and into the upper rail box. The note draws a correct and an incorrect position for the shaft.
Check: The pulley shaft is fully seated in the upper rail box
Restore the belt tension
Slide the upper rail box back until it lines up with the mark made earlier. Tighten the set screw.
Check: The upper rail box sits on its original mark
Fit the bearing and new lower rail box
Slide the new bearing onto the new pulley shaft.
Fit the new lower rail box over the upper rail box. Drive its four screws until snug.
Warning: Take care not to over-tighten the four screws
Re-install the track
Mount the drapery track back on the ceiling or the wall. Lutron prints this step at the foot of page 4, after steps 10 to 13.
Mount the new EDU, change the terminal block
Mount the new EDU following document 045121, the Sivoia QED drapery installation and operating instructions. At the transformer, wall control or power panel, replace the 7-pin terminal block with the new one, per document 045121.
Power up and set limits
Restore power to the transformer and the EDU. Set the limits from the EDU as document 045121 describes.
Check: Limits are set from the EDU
Facts Lutron states in 045129
The values Lutron document 045129 states, as published:
- System covered
- An existing Sivoia QED drapery track system retrofitted with the enhanced Sivoia QED drapery EDU
- First step
- Unplug the drive at the EDU, cut power to its transformer, then take the track down
- EDU fixing
- Three screws hold the EDU to the lower rail box
- Lower rail box side
- A small flat-head screwdriver removes the side that held the EDU screw heads
- Lower rail box
- Four screws hold the lower rail box to the upper rail box
- New lower rail box screws
- Four screws, tightened until snug and not over-tightened
- Pulley shaft
- The new pulley shaft passes through the plastic pulley into the upper rail box and must seat fully
- Belt tension
- Mark the upper rail box position on the track
- Loosen the set screw with the 5/64 in hex wrench
- Slide the box to slacken the belt
- Return the box to the mark and retighten
- Bearing
- The new bearing goes onto the new pulley shaft before the new lower rail box goes on
- Finishing steps
- Mount the new EDU per document 045121
- Swap the 7-pin terminal block at transformer, wall control or power panel
- Reapply power and set limits from the EDU
- Power back on
- Power returns only after the new EDU and 7-pin terminal block are fitted, at step 12 of 13
- Parts that change
- EDU, pulley shaft, bearing, lower rail box and 7-pin terminal block
- Parts kept
- The track and the upper rail box
Questions about document 045129
The answers come from Lutron document 045129 and New Way's record of it.
What is Lutron document 045129?
Lutron's four-page Sivoia application note #13, 13 numbered steps, printed P/N 045-129 Rev A with a 2007 copyright line.
Which revision of 045129 is current?
Rev A is the revision Lutron publishes. New Way checked it against assets.lutron.com on 16 October 2026.
Which roller shades does 045129 cover?
Lutron Sivoia QS roller shades. Lutron document 045129 refers readers to document 045121.
Which drapery system does this note apply to?
Lutron document 045129 applies to an existing Sivoia QED drapery track being fitted with the enhanced Sivoia QED EDU. Lutron does not mention Sivoia QS anywhere in the note.
What parts are replaced in the retrofit?
Lutron document 045129 replaces these parts and keeps the track, upper rail box and belt.
- EDU, pulley shaft and bearing
- Lower rail box
- 7-pin terminal block at the transformer, wall control or power panel
Which tools does the retrofit need?
Lutron document 045129 names a small flat-head screwdriver and a 5/64 in hex wrench. The screwdriver opens the lower rail box side, and the wrench turns the belt tension set screw.
The note names no tool for the three EDU screws and the four rail box screws.
Why adjust the belt tension, and how is it restored?
Lutron document 045129 eases the belt so the new pulley shaft goes in more easily.
- Mark where the upper rail box sits on the track
- Loosen the set screw with the hex wrench and slide the box
- Shaft in: return the box to the mark, restoring the original tension
Does the drapery track have to come down for the retrofit?
Yes, Lutron document 045129 removes the track from the ceiling or wall at step 2. The drive is unplugged and its transformer off first.
The track goes back up at step 9, once the new bearing and lower rail box are fitted.
Other Sivoia QS application notes
Application notes for the same Sivoia QS system:
| Document | Drive class | Revision | Date |
|---|---|---|---|
| Application Note: QSE-CI-NWK-E Phantom Button User Guide for Integrating Shades and Venetian Blinds | Roller 20 to 300 | B | Mar 2011 |
| Application Note: Shade Drive Upgrade Guide | Roller 20 to 300 | A | |
| 048846Application Note: EU EcoDesign Standby Power Information | A | Nov 2024 | |
| 048863Roller Shades Application Note: Fabric Aesthetic Characteristics | Clutch, Commercial Contract Manual | A | May 2026 |
Documents used with 045129
Lutron document 045129 is the companion to document 045121, cited for the new EDU, the terminal block and the limits. Lutron's 2007 note names only the Sivoia QED track and drive.
| Document | Type | Revision | Date |
|---|---|---|---|
| 045959Wired Power Roller Shade Mounting Installation Guide | Installation Guide | C | Sep 2025 |
| Installation Guide: QS Wireless Power Supply Wiring Guidelines | Installation Guide | ||
| Roller Shades Revit Family: Shade Pockets | Revit Family | ||
| Roller Shades Revit Family: Side Channels and Sill Angles | Revit Family | ||
| 3672148Roller Shades Product Brochure: Commercial Selection Guide | Product Brochure | F | Mar 2016 |
| 0853144-Group RF Remote Control Specification Submittal | Specification Submittal | C | May 2016 |
| 369847Pico Wireless Control, 4-Button Specification Submittal | Specification Submittal | K | Mar 2024 |
| CAD Drawing: Shade Equipment CAD Block | CAD Drawing | ||
| 085612Roller 100 CAD Drawing: 4.75″ x 5″ (121 x 127mm) Pocket, Detail Drawing | CAD Drawing | A | |
| 085274Hard Wired Power Supply Specification Submittal | Specification Submittal | D | Aug 2014 |
Revisions of 045129
This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.
| Revision | Date | Status |
|---|---|---|
| A | Not stated | Current. The file on assets.lutron.com. Checked 16 Oct 2026. |
Not covered in 045129, and what to read next
Lutron document 045129 does not show mounting the new EDU, wiring the new 7-pin terminal block or setting limits.
- Next: 045121, the Sivoia QED drapery installation and operating instructions
- Sivoia QS tracks: 045982, the Sivoia QS drapery installation guide
Publisher and citation for document 045129
Lutron Electronics Co., Inc. publishes document 045129, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 16 October 2026.
Lutron and Sivoia QS are trademarks of Lutron Electronics Co., Inc.
Reviewed by Edmond Hong, Technical Specialist, New Way.
Specifying Sivoia QS?
New Way supplies and installs Lutron Sivoia QS shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.
The form opens with document 045129 filled in.