085769 · CAD Drawing · Rev A · English · PDF, DWG, DXF

Lutron Sivoia QS Roller 64 CAD Drawing: WIDR Shade Mount with 4″ Fascia Brackets (Reverse Roll), Elevation View (085769)

Lutron's elevation view of the Roller 64 4 in fascia mount shade with fascia brackets, reverse roll.

About document 085769

Lutron drawing 085769, Rev A, is the one-page reverse roll fascia elevation at 1/4 scale, view 2: minimum shade width and height, minimum light gap, mounting and clearance notes, as PDF, DWG and DXF.

What drawing 085769 covers

Lutron document 085769 has these six sections, all on its one page.

  1. Elevation of the fascia mount shade, reverse roll
  2. Minimum width and minimum height of shade
  3. Minimum light gap and the quote pointer
  4. Mounting configurations the fascia bracket allows
  5. Clearance note and adjustment limits
  6. Legend in top view and title block

Specifications in 085769

Lutron document 085769 prints 14 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.

Minimum width of shade
17.5 in (445 mm), printed in parentheses
Minimum shade height
12 in (305 mm)
Minimum light gap
0.75 in (19 mm)
Actual light gap
Refer to the quote
Unlabeled dimension
3.31 in (85 mm)
Configurations the bracket supports
Ceiling, wall or jamb (wall mount shown)
Clearances
Set at the factory; kept by the installer when adjustment features are used
Adjustments at maximum roll diameter
Not all available
Product
Roller 64
Shade
4 in fascia mount shade with fascia brackets, reverse roll
Number as printed
085769
Scale
1/4
View
2
Revision
A

Facts Lutron states in 085769

The values Lutron document 085769 states, as published:

What the drawing shows
An elevation of a Roller 64 shade on a 4 in fascia mount, reverse roll, wall mount drawn
Minimum width of shade
17.5 in (445 mm), printed inside parentheses
Minimum shade height
12 in (305 mm)
Minimum light gap
0.75 in (19 mm)
Actual light gap
Lutron refers the reader to the quote
Mounting configurations
Lutron's bracket supports ceiling, wall or jamb mounting, with the wall mount drawn
Clearances as supplied
A shade installed as the factory supplies it has the clearances it needs to run
Adjustment features
Once adjustment features are used, Lutron makes the installer responsible for keeping proper clearances
Adjustment at full roll
Lutron notes that not all adjustments are available at the maximum roll diameter
Unlabeled dimension
3.31 in (85 mm)
Title block
Roller 64, number 085769, scale 1/4, view 2, revision A
Files offered
PDF, DWG and DXF

Questions about document 085769

The answers come from Lutron document 085769 and New Way's record of it.

What is the smallest reverse roll shade on the fascia mount?

Lutron drawing 085769 prints a minimum width of 17.5 in (445 mm) and a minimum height of 12 in (305 mm). Lutron draws these for the reverse roll fascia shade, width inside parentheses.

Which revision of 085769 is current?

Rev A is the revision Lutron publishes. New Way checked it against assets.lutron.com on 16 October 2026.

Which roller shades does 085769 cover?

Lutron Sivoia QS roller shades in the Roller 64 drive class.

What light gap does the reverse roll fascia shade allow?

Lutron drawing 085769 prints a minimum light gap of 0.75 in (19 mm). Lutron refers the reader to the quote for the actual light gap.

Which surfaces can the Roller 64 fascia bracket be fixed to?

Lutron's note on drawing 085769 says the bracket supports ceiling, wall or jamb mounting. Lutron's elevation shows the wall mount.

What happens to the clearances if the installer adjusts the bracket?

Lutron states that a shade installed as the factory supplies it has the clearances it needs to run. Once adjustment features are used, Lutron makes the installer responsible for keeping proper clearances.

Lutron notes that not all adjustments are available at the maximum roll diameter.

How does the reverse roll sheet relate to the regular roll sheet?

Lutron drawing 085769 covers the reverse roll, and Lutron drawing 085768 is the matching elevation view for the regular roll. Lutron prints separate values on each sheet, so read the regular roll figures from 085768.

Does the reverse roll elevation give a fascia height or hembar size?

No, Lutron drawing 085769 labels only the minimum width, minimum shade height and minimum light gap. Lutron prints one further dimension, 3.31 in (85 mm), without a label.

Ask about 085769

Other Sivoia QS Roller 64 CAD drawings

CAD drawings for the same Sivoia QS Roller 64 drive class:

All 142 Sivoia QS CAD drawings

Documents used with 085769

Lutron drawing 085768 is the regular roll elevation, 085764 its section with top back cover and 045929 its installation guide. Lutron's fascia details are 085774 and 085775, brackets 085776 and 085777, top back covers 085772 and 085773, end cap 085767.

Revisions of 085769

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
ANot statedCurrent. The file on assets.lutron.com. Checked 16 Oct 2026.

Not covered in 085769, and what to read next

Lutron drawing 085769 gives no section through the shade head, no fascia or bracket profile dimensions and no installation steps.

  • Section: 085765, the reverse roll section view with top back cover
  • Installation: 045930, the reverse roll 4 in fascia mount chassis guide

Publisher and citation for document 085769

Lutron Electronics Co., Inc. publishes document 085769, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 16 October 2026.

Lutron and Sivoia QS are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Sivoia QS?

New Way supplies and installs Lutron Sivoia QS shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.

The form opens with document 085769 filled in.