Contact Us
Opens in a new tab

085569 · CAD Drawing · Rev B · English · PDF, DWG, DXF

Lutron Serena Roller Shades CAD Drawing: Wired, No Top Treatment, Section View (085569)

Lutron's section view of a Serena or Triathlon wired roller shade with no top treatment, for head details.

About document 085569

Lutron drawing 085569, revision B, is the one-page CAD section of the wired shade with no top treatment: tube, roll-up and tube center dimensions, a mounting note and a clearance note.

What drawing 085569 covers

Lutron document 085569 has these six sections, all on its one page.

  1. Section view through the head, ceiling mount
  2. Tube, roll-up and tube center dimensions
  3. Legend (top view), view markers 1 and 2
  4. Mounting configuration note
  5. Clearance and adjustment note
  6. Title block

Specifications in 085569

Lutron document 085569 prints 18 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.

Tube diameter
Ø1.67 in (43 mm)
Maximum roll-up
Ø2.60 in (64 mm)
Tube center (smaller of two printed)
1.75 in (44 mm)
Tube center (larger of two printed)
2.25 in (57 mm)
Unlabeled dimension
3.06 in (77 mm)
Unlabeled dimension
3.56 in (90 mm)
Unlabeled dimension
0.44 in (11 mm)
Hembar
Varies
Glazing
Typical
Configurations the bracket supports
Wall or ceiling (ceiling mount shown)
Clearances
Provided by the factory; kept by the installer if adjustment features are used
Adjustments at maximum roll diameter
Not all available
Configuration
Wired, no top treatment
Product
Serena/Triathlon
Number as printed
085569
Scale
1/2
View
1
Revision
B

Facts Lutron states in 085569

The values Lutron document 085569 states, as published:

What the drawing shows
A section through a Serena or Triathlon wired roller shade with no top treatment, ceiling mount shown
Tube diameter
1.67 in (43 mm)
Maximum roll-up
2.60 in (64 mm) diameter
Tube center
Two tube center dimensions, 1.75 in (44 mm) and 2.25 in (57 mm), printed without saying which surface each is measured from
Fascia
None dimensioned on the sheet, whose heading reads no top treatment
Hembar
Marked as varying, with no hembar size printed
Glazing
Drawn as typical
Mounting configurations
Lutron's bracket supports wall or ceiling mounting, with the ceiling mount drawn
Clearances as supplied
A shade installed as Lutron's factory supplies it has the clearances it needs to operate
Adjustments
The installer keeps the clearances if the adjustment features are used
Adjustment at full roll
Not all adjustments are available at the maximum roll diameter
Title block
Serena/Triathlon, 085569, scale 1/2, view 1, revision B
Files
PDF, with DWG and DXF versions of the same drawing

Questions about document 085569

The answers come from Lutron document 085569 and New Way's record of it.

What is Lutron drawing 085569?

Lutron drawing 085569 is view 1 at scale 1/2, revision B, published as PDF, DWG and DXF files. Lutron draws the bracket on the ceiling and the glazing as typical.

Which revision of 085569 is current?

Rev B is the revision Lutron publishes. New Way checked it against assets.lutron.com on 16 October 2026.

Which roller shades does 085569 cover?

Lutron Triathlon roller shades.

Where does the tube sit on the no top treatment section?

Lutron prints two tube center dimensions on drawing 085569, 1.75 in (44 mm) and 2.25 in (57 mm). Lutron does not say which surface each is measured from.

Is the section drawn as a wall mount or a ceiling mount?

Lutron's drawing 085569 shows the ceiling mount. Lutron's note on the sheet says the same bracket supports wall or ceiling mounting.

What happens to the clearances if the bracket is adjusted?

Lutron drawing 085569 states that a shade fitted as supplied has the clearances it needs to run. Lutron makes the installer responsible for keeping them once the adjustment features are used.

Some adjustments are unavailable at the maximum roll diameter.

How large does the rolled fabric get?

Lutron shows a 1.67 in (43 mm) tube and a maximum roll-up diameter of 2.60 in (64 mm) on drawing 085569.

Does the section show a fascia or a hembar size?

Lutron dimensions no fascia on drawing 085569, whose heading reads no top treatment. Lutron marks the hembar as varying and prints no hembar size.

Ask about 085569

Other Triathlon CAD drawings

CAD drawings for the same Triathlon system:

All 13 Triathlon CAD drawings

Documents used with 085569

Lutron drawings 085570 (matching elevation) and 085571 (wired, fabric wrapped fascia section) are the related views. Lutron specification submittals 085312 (Serena) and 085333 (Triathlon) cover the shades; 045868 is the Serena wired roller drive replacement guide.

Revisions of 085569

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
BNot statedCurrent. The file on assets.lutron.com. Checked 16 Oct 2026.

Not covered in 085569, and what to read next

Lutron drawing 085569 gives no shade widths, heights, light gaps, wiring or installation steps.

  • Elevation: 085570, the matching elevation view of the same shade
  • Shade data: 085312, the Serena roller shades specification submittal

Publisher and citation for document 085569

Lutron Electronics Co., Inc. publishes document 085569, Rev B, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 16 October 2026.

Lutron, Triathlon and Serena are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Triathlon?

New Way supplies and installs Lutron Triathlon shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.

The form opens with document 085569 filled in.