About document 085635

Lutron document 085635, Rev B at scale 1/3, is the manual dual shade fascia and back cover section: bracket height and depth, fascia depth, tube and roll-up diameters, tube centers, back cover deduction, mounting notes.

What drawing 085635 covers

Lutron document 085635 has these nine sections, all on its one page.

  1. Section view, ceiling mount shown
  2. Bracket height and depth, fascia depth
  3. Tube diameter, optional tubes and maximum roll-up
  4. Tube center dimensions
  5. Back cover deduction note
  6. Chain tensioner note
  7. Legend (top view) and mounting note
  8. Clearance and adjustment note
  9. Title block: code, number, scale, view, revision

Specifications in 085635

Lutron document 085635 prints 28 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.

Bracket height with fascia
8.06 in (204 mm)
Bracket depth with fascia (starred)
6.13 in (156 mm)
Fascia depth
1.06 in (27 mm)
Tube diameter
Ø1.75 in (44 mm)
Optional tube diameters
Ø2.56 in (65 mm) or Ø2.00 in (51 mm)
Maximum roll-up, first shade
Ø3.35 in (85 mm)
Maximum roll-up, second shade
Ø3.35 in (85 mm)
Tube center
2.25 in (57 mm)
Tube center
5.81 in (148 mm)
Tube center (starred)
3.94 in (99 mm)
Tube center (starred)
2.31 in (59 mm)
Unlabeled dimension (starred)
2.25 in (57 mm)
Unlabeled dimension (starred)
0.63 in (17 mm)
Hembar
Varies (two hembars drawn)
Fixing shown
Ceiling fasteners
Parts labeled
Bracket, back cover, dual fascia
Without back cover
Deduct 0.11 in from the starred dimensions
Bracket mounting
Ceiling or wall (ceiling mount shown)
Chain tensioner
Wall or floor mounted
Clearances
Set at the factory; kept by the installer when adjustment features are used
Adjustments at maximum roll diameter
Not all available
Product
Contract Roller Manual
Sheet title
Dual fascia and back cover bracket
Code
CHR-C
Number as printed
085635
Scale
1/3
View
1
Revision
B

Facts Lutron states in 085635

The values Lutron document 085635 states, as published:

What the drawing shows
A section through a Contract Roller Manual dual shade with dual fascia and back cover, bracket fixed with ceiling fasteners
Bracket height with fascia
8.06 in (204 mm)
Bracket depth with fascia
6.13 in (156 mm), a starred dimension
Fascia depth
1.06 in (27 mm)
Tube diameter
Ø1.75 in (44 mm), optional Ø2.56 in (65 mm) or Ø2.00 in (51 mm)
Maximum roll-up
Ø3.35 in (85 mm) on each of the two shades
Tube center dimensions
  • 2.25 in (57 mm)
  • 5.81 in (148 mm)
  • 3.94 in (99 mm), starred
  • 2.31 in (59 mm), starred
Without back cover
Deduct 0.11 in from every starred dimension, with no metric figure given for the deduction
Mounting
Ceiling or wall mounting of the bracket, with the ceiling mount shown
Chain tensioner
Wall or floor mounted
Clearances
  • Factory-supplied shades have the clearances they need
  • The installer keeps them once adjustment features are used
  • Not every adjustment is available at maximum roll diameter
Title block
Contract Roller Manual, dual fascia and back cover bracket, CHR-C, 085635, scale 1/3, view 1, revision B

Questions about document 085635

The answers come from Lutron document 085635 and New Way's record of it.

What is Lutron document 085635?

Lutron's one-page section drawing, view 1 under code CHR-C, with no clutch side stated on the sheet.

Which revision of 085635 is current?

Rev B is the revision Lutron publishes. New Way checked it against assets.lutron.com on 16 October 2026.

Which roller shades does 085635 cover?

Lutron Manual roller shades in the Commercial Contract Manual drive class.

How much height does the Contract Roller dual bracket with fascia need?

Lutron document 085635 gives a bracket height with fascia of 8.06 in (204 mm). Lutron draws the bracket fixed to the ceiling with ceiling fasteners.

What changes if the back cover is left out?

Lutron document 085635 says to deduct 0.11 in from each starred dimension when the back cover is not installed. Lutron stars the 6.13 in (156 mm) bracket depth with fascia, two tube center dimensions and two dimensions that carry no label.

Can the dual bracket be wall mounted instead?

Yes, Lutron's note on drawing 085635 allows ceiling or wall mounting of the bracket, with the ceiling mount drawn. The chain tensioner can go on the wall or the floor.

What must the installer watch when using the bracket adjustments?

Lutron document 085635 states that a shade installed as supplied from the factory has the clearances it needs. Lutron makes the installer responsible for those clearances once adjustment features are used.

Some adjustments are not available at maximum roll diameter.

How deep is the head with the fascia fitted?

Lutron document 085635 dimensions the bracket depth with fascia at 6.13 in (156 mm) and the fascia depth at 1.06 in (27 mm). Lutron's back cover deduction of 0.11 in applies to the 6.13 in figure.

Ask about 085635

Other Manual Commercial Contract Manual CAD drawings

CAD drawings for the same Manual Commercial Contract Manual drive class:

All 20 Manual roller shade CAD drawings

Documents used with 085635

Lutron documents 085375 (both clutches right) and 085376 (clutches left and right) draw the manual dual shade in a pocket. Lutron document 085636 is the motorized dual shade section with fascia and back cover.

Revisions of 085635

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
BNot statedCurrent. The file on assets.lutron.com. Checked 16 Oct 2026.

Not covered in 085635, and what to read next

Lutron drawing 085635 gives one section view: shade widths, fabric, bracket spacing and fastener sizes are not on the sheet.

  • Recessed pocket: 085375 or 085376, the manual dual shade pocket sections
  • Servicing: 048710, the dual fascia removal application note

Publisher and citation for document 085635

Lutron Electronics Co., Inc. publishes document 085635, Rev B, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 16 October 2026.

Lutron is a trademark of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Manual roller shades?

New Way supplies and installs Lutron Manual roller shades in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.

The form opens with document 085635 filled in.