Contact Us
Opens in a new tab

085598 · CAD Drawing · Rev A · English · PDF, DWG, DXF

Lutron Palladiom Roller Shades CAD Drawing: Wired Shade, Dual Ceiling Mount, Section View (085598)

Lutron's dual ceiling mount section view CAD drawing of two wired Palladiom roller shades, with tube sizes and clearances.

About document 085598

Lutron drawing 085598, Rev A, is the section of two wired Palladiom shades on a dual ceiling mount: tube diameter and maximum roll-up, tube center dimensions, minimum recommended clearance, hembars, glazing, mounting note and legend.

What drawing 085598 covers

Lutron document 085598 has these eight sections, all on its one page.

  1. Section view: dual ceiling mount shades
  2. Tube diameter and maximum roll-up
  3. Tube center dimensions
  4. Minimum recommended clearances and reference dimension
  5. Hembars and glazing
  6. Mounting configurations note
  7. Legend (top view)
  8. Installer clearance note

Specifications in 085598

Lutron document 085598 prints 15 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.

Section view, view 1, scale 1/2

PDF page 1 of 085598, opens in a new tab
Tube diameter
Ø2.00 in (51 mm), printed for each shade
Max roll up
Ø3.00 in (76 mm), printed for each shade
Tube center
2.00 in (51 mm)
Tube center
2.375 in (60 mm)
Tube center
5.875 in (149 mm)
Minimum recommended clearance
0.50 in (13 mm), printed twice
Reference dimension
0.875 in (22 mm), with the 0.50 in minimum recommended clearance
Hembar
Varies (two hembars drawn)
Glazing
Typical
Bracket mounting
Ceiling or wall; ceiling mount shown
Markers
1 and 2
Drawing number
085598
Scale
1/2
View
1
Revision
A

Facts Lutron states in 085598

The values Lutron document 085598 states, as published:

What the drawing shows
A section through two Palladiom shades on a dual ceiling mount, with the glazing and both hembars. A top-view legend is keyed 1 and 2.
Tube diameter
Ø2.00 in (51 mm), each shade
Maximum roll-up diameter
Ø3.00 in (76 mm), each shade
Tube center dimensions
Three dimensions, each labeled tube center:
  • 2.00 in (51 mm)
  • 2.375 in (60 mm)
  • 5.875 in (149 mm)
Minimum recommended clearance
0.50 in (13 mm), printed twice
Reference dimension
0.875 in (22 mm), noted with the 0.50 in minimum recommended clearance
Mounting options
The bracket supports ceiling or wall mounting, with the ceiling mount shown
Hembar
Varies, on both shades
Clearance responsibility
A shade installed as the factory supplies it has the clearances it needs to operate. The master technician keeps those clearances after installation.
Title block
Drawing 085598, view 1, scale 1/2, revision A
File formats
PDF, with DWG and DXF files of the same drawing

Questions about document 085598

The answers come from Lutron document 085598 and New Way's record of it.

What is Lutron document 085598?

Lutron's one-sheet section through two Palladiom shades on a dual ceiling mount, drawn as view 1 at scale 1/2. Lutron draws the glazing and both hembars, with a top-view legend keyed 1 and 2.

Lutron publishes the sheet as a PDF with matching DWG and DXF files.

Which revision of 085598 is current?

Rev A is the revision Lutron publishes. New Way checked it against assets.lutron.com on 16 October 2026.

Which roller shades does 085598 cover?

Lutron Palladiom roller shades.

Can the shades on drawing 085598 be wall mounted instead?

Lutron drawing 085598 states that multiple mounting configurations are allowed and that the bracket supports ceiling or wall mounting. Lutron shows the ceiling mount here; the dual wall mount section view is drawing 085601.

What clearances does drawing 085598 call for?

Lutron drawing 085598 prints a 0.50 in (13 mm) minimum recommended clearance twice. A 0.875 in (22 mm) reference dimension carries the same 0.50 in minimum.

Lutron makes the master technician responsible for keeping the clearances after installation.

What are the tube center dimensions?

Lutron drawing 085598 prints three tube center dimensions, without naming the surface each is measured from.

  • 2.00 in (51 mm)
  • 2.375 in (60 mm)
  • 5.875 in (149 mm)

What tube and roll-up diameters does the dual ceiling mount use?

Lutron drawing 085598 prints a Ø2.00 in (51 mm) tube diameter and a Ø3.00 in (76 mm) maximum roll-up for each shade.

Does drawing 085598 fix the hembar size?

Lutron drawing 085598 marks both hembars as varying and gives no hembar dimension.

Ask about 085598

Other Palladiom CAD drawings

CAD drawings for the same Palladiom system:

All 38 Palladiom CAD drawings

Documents used with 085598

Lutron drawings 085601, 085597 and 085605 are the dual wall, dual jamb, and dual jamb and wall mount sections. Lutron drawing 085582 is the single-shade ceiling mount section, and 085734 the wire-free dual ceiling mount section.

Revisions of 085598

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
ANot statedCurrent. The file on assets.lutron.com. Checked 16 Oct 2026.

Not covered in 085598, and what to read next

Lutron drawing 085598 shows the section only, with no elevation, plan, bracket size, fastener or wiring detail.

  • Wall mount pair: 085601, the dual wall mount section view CAD drawing
  • One shade: 085582, the single ceiling mount section view CAD drawing

Publisher and citation for document 085598

Lutron Electronics Co., Inc. publishes document 085598, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 16 October 2026.

Lutron and Palladiom are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Palladiom?

New Way supplies and installs Lutron Palladiom shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.

The form opens with document 085598 filled in.