Contact Us
Opens in a new tab

048736 · Application Note · Rev C · Jul 2022 · English · PDF, 15 pages, 12.6 MB

Lutron Sivoia QS Application Note: Maximizing Light Blockage with Guestroom Window Treatments (048736)

Lutron's application note on blocking outside light with motorized drapery and roller shades in hotel guestrooms and bedrooms.

About document 048736

Lutron document 048736, Application Note #736, Revision C of July 2022, is the guestroom light-blocking design guide: top, side, center-draw and floor gaps for drapery, then Roller 100 or Roller 225 shades with side channels.

What note 048736 covers

Lutron document 048736 has these twelve sections. Each link opens the PDF at that page in a new tab.

  1. Overview and important notes, opens in a new tab page 1
  2. Drapery quick-reference configurations A and B, opens in a new tab page 2
  3. Drapery light gap along the top, opens in a new tab page 2
  4. Stack-back clearance and ceiling mounting, surface versus recess, opens in a new tab page 4
  5. Reducing the light gap along the sides, opens in a new tab page 5
  6. Light gap between center-draw panels, opens in a new tab page 6
  7. Overlap hanger bars for ripplefold systems, opens in a new tab page 9
  8. Drapery light gap along the bottom, opens in a new tab page 10
  9. Roller shade configuration: Roller 100 versus Roller 225, opens in a new tab page 10
  10. Selecting a blackout fabric, opens in a new tab page 11
  11. Roller shade light gap along the top, opens in a new tab page 12
  12. Side channels, hembar, sill angle, blackout summary, opens in a new tab page 14

Specifications in 048736

Lutron document 048736 prints 54 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.

Quick-reference configuration A (drapery, preferred)

PDF page 2 of 048736, opens in a new tab
Mounting style
Outside mount, overlapping the window opening by at least 12 in (305 mm) on all sides and the top
Draw style
Side draw
Drapery styles
Pinch pleat or ripplefold
Valance or fascia, minimum
11.5 in (292 mm) wide for dual tracks x 12 in (305 mm) deep

Quick-reference configuration B (drapery)

PDF page 2 of 048736, opens in a new tab
Mounting style
Inside mount, surface mounted, not recessed
Draw style
Center draw with maximum overlap; pinch pleat recommended
Stationary sides
Attached to the wall
Pocket or fascia, minimum
11.5 in (292 mm) wide for dual tracks x 12 in (305 mm) deep

Reducing light gap along the top (drapery)

PDF pages 2, 3 and 5 of 048736, opens in a new tab
Track height above the top of the window
Ideally 8 to 12 in (203 to 305 mm) or more, close to the ceiling
Figure 1.1a, other printed values
1/2 in (13 mm); 5/8 in (16 mm); 1/2 to 1 in (13 to 25 mm)
Interior pocket height
At least 12 in (305 mm) recommended
Interior pocket width, single track
7 in (178 mm) minimum, for stack-back clearance
Interior pocket width, dual track
11.5 in (292 mm) minimum, for stack-back clearance
Figure 1.1d, single system section
Minimum pocket depth 7 in (178 mm); 12 in (305 mm); 3.5 in (89 mm) twice
Figure 1.1d, dual-track system section
Minimum pocket depth 12.5 in (318 mm); 12 in (305 mm); 3.5 in (89 mm) twice; 5.5 in (140 mm)
Ceiling mounting
Surface mount and pinch pleat fabric preferred over recess mount

Reducing light gap along the sides (drapery)

PDF pages 5 and 6 of 048736, opens in a new tab
Side pocket or wall overlap depth
12 in (305 mm) minimum recommended
Stationary ends, inside mount
Fixed to the jamb with hook-and-loop strips or 2-sided adhesive tape

Reducing light gap between center-draw panels

PDF pages 6, 7 and 8 of 048736, opens in a new tab
Alena center draw, standard hanger bars, maximum overlap
3.00 in (76.0 mm)
Alena center draw, extended hanger bars, maximum overlap
6.00 in (150.0 mm)
Alena tandem draw, extended hanger bars, maximum overlap with cars against the idler
3.50 in (89.0 mm)
Sivoia QS center draw, standard hanger bars, maximum overlap
3.89 in (98.9 mm)
Sivoia QS center draw, extended hanger bars, maximum overlap
8.30 in (210.9 mm)
Sivoia QS tandem draw, extended hanger bars, maximum overlap with cars against the idler
3.15 in (80.0 mm)
Car-to-car spacing
1.25 in (31.8 mm)
Extended hanger bars
Custom request, quoted by Lutron

Overlap hanger bars for ripplefold systems

PDF page 9 of 048736, opens in a new tab
Sivoia QS center-draw ripplefold closure
Butt closure standard; overlap hanger bars by custom request
Alena center-draw ripplefold closure
Overlap hanger bars standard; butt closure by custom request
Idler-end and drive-end snap brackets
Accept 3 male snaps each
Master carriers
Sivoia QS: 3 male snaps each; Alena: 3 female snaps each
Overlap closure, auxiliary snaps
Right fabric panel has one more auxiliary snap than the left

Reducing light gap along the bottom (drapery)

PDF page 10 of 048736, opens in a new tab
Drapery to floor clearance
0.5 in (12 mm) minimum; no fabric pooling on the floor
Roller 100
Appropriate for most windows
Roller 225
When the shade panel must exceed 15 ft (4.57 m) wide and/or 10 ft (3.05 m) tall
Roller 225 sub-bracket and roll direction
Reversed compared with Roller 100

Quick-reference configuration (roller shades)

PDF page 10 of 048736, opens in a new tab
Components
Roller 100 (or Roller 225); pocket or fascia mount; blackout fabric; side channels; exposed hembar with black wool pile; sill angle
Search filters on lutronfabrics.com
Shade Type: Roller Shades; Openness: Blackout; Additional Properties: Fire Rated

Reducing light gap along the top (roller shades)

PDF pages 12 and 13 of 048736, opens in a new tab
Figure 2.3a, Roller 100 fascia mount, printed values
4.20 in (107 mm) twice; fascia with top back cover; regular roll shown
Figure 2.3b, Roller 100 pocket mount, printed values
4.75 in (121 mm); 5.0 in (127 mm); pocket flap; regular roll shown
Pocket interior finish
Dark, non-reflective color
Roller 225 pocket depth
7.00 in (178 mm)
Roller 225 pocket height
7.00 in (178 mm)
Roller 225 tube diameter
3.75 in (95 mm)
Roller 225 maximum roll-up
5.25 in (133 mm) diameter
Roller 225 tube center
3.81 in (96 mm) and 3.38 in (86 mm), as printed
Roller 225 projection adjust
-0.5/+0 in (-13/+0 mm)
Figure 2.3c, other printed values
0.81 in (20 mm); 1.00 in (25 mm); 1.19 in (30 mm)

Reducing light gap along the sides (roller shades)

PDF page 14 of 048736, opens in a new tab
Side channels
2.5 in (63.5 mm), interior black wool pile
Battens on tall shades
Every 5 ft (1.53 m) on shades 10 ft (3.05 m) tall or taller
Inclined shades
Side channels not compatible beyond 5° from vertical
Not compatible with side channels
Cable guides on the same shade; battery-powered shades
Sheer fabric
Side channels do not make a sheer shade full blackout

Reducing light gap along the bottom (roller shades)

PDF page 14 of 048736, opens in a new tab
Options
Exposed hembar with black wool pile, a sill angle, or both
Sill angle at a point of egress
Not to be used (trip hazard)

Facts Lutron states in 048736

The values Lutron document 048736 states, as published:

Preferred drapery configuration
  • Configuration A: outside mount, side draw, pinch pleat or ripplefold
  • Overlap of at least 12 in (305 mm) on all sides and top
  • Valance or fascia at least 11.5 in (292 mm) wide for dual tracks
  • Valance or fascia at least 12 in (305 mm) deep
Track height above the window
Ideally 8 to 12 in (203 to 305 mm) or more above the window head, near the ceiling, since a higher track blocks more light
Drapery pocket minimums
  • Interior height at least 12 in (305 mm)
  • Interior width 7 in (178 mm) for a single track
  • Interior width 11.5 in (292 mm) for dual tracks, for stack-back clearance
Inside mount rules
  • Pinch pleat preferred, because the fabric can overlap the track
  • Ripplefold hangs below the track and leaves a gap
  • On a ceiling, surface mount beats recess
  • Stationary ends fixed to the jamb with hook-and-loop strips or double-sided tape
Side pockets or wall overlap
Minimum 12 in (305 mm) depth recommended along the sides of the opening
Maximum hanger bar overlap
  • Sivoia QS: 3.89 in (98.9 mm) standard bars, 8.30 in (210.9 mm) extended bars
  • Alena: 3.00 in (76.0 mm) standard bars, 6.00 in (150.0 mm) extended bars
  • Extended hanger bars are a custom quotation
  • The drive's close limit can be set for less overlap
Center-draw ripplefold closures
  • Sivoia QS: butt closure standard, overlap hanger bars by custom request
  • Alena: overlap standard, butt closure by request
  • Alena master carriers need female snaps
Drapery to floor
Minimum 0.5 in (12 mm) clearance so the fabric hangs free, never pooling on the floor, where dragging can stop the panels overlapping
Roller 100 versus Roller 225
  • Roller 100 suits most windows
  • Roller 225: panel over 15 ft (4.57 m) wide and/or 10 ft (3.05 m) tall
  • Roller 225 sub-bracket and roll direction reversed
  • Roller 225 pocket: 7.00 in (178 mm) high by 7.00 in (178 mm) deep
Side channels and sill angle
  • 2.5 in (63.5 mm) side channels, black wool pile, position set by mock-up
  • Not with cable guides, battery-powered shades or shades over 5° from vertical
  • No full blackout with sheer fabric
  • No sill angle at a point of egress
Scope of supply
Lutron supplies the drapery track hardware only, not the fabric, so the track installer coordinates with the drapery workroom
Roller shade supply
Roller shades ship with the fabric already on the roller
How to judge the result
A mock-up in actual site conditions is Lutron's method for measuring how well a window treatment blocks light
Drapery panel weight
Not printed: the maximum panel weight depends on the system configuration and is given on the quotation

Questions about document 048736

The answers come from Lutron document 048736 and New Way's record of it.

What is Lutron document 048736?

Lutron document 048736 is a 15-page note aiming at a 'tortured path' for light, judged by a mock-up on site.

Which revision of 048736 is current?

Rev C, dated July 2022, is the revision Lutron publishes. New Way checked it against assets.lutron.com on 16 October 2026.

Which roller shades does 048736 cover?

Lutron Sivoia QS roller shades. Lutron document 048736 refers readers to document 086106.

Which drapery configuration blocks the most light?

Lutron document 048736 prefers configuration A, a side-draw track outside the window opening, with these minimums.

  • Overlap: 12 in (305 mm) on all sides and top
  • Valance or fascia: 11.5 in (292 mm) wide for dual tracks, 12 in (305 mm) deep

Lutron pairs it with a pocket or fascia-mounted blackout roller shade with side channels.

When does a guestroom need Roller 225 instead of Roller 100?

Lutron document 048736 names Roller 100 for most windows. Roller 225 applies when the shade panel exceeds 15 ft (4.57 m) wide and/or 10 ft (3.05 m) tall.

Lutron warns that the Roller 225 sub-bracket and roll direction are reversed, and refers to specification documents 086106 and 086105.

How far do center-draw panels overlap?

Up to 3.89 in (98.9 mm) on a Sivoia QS center-draw pinch pleat track with standard hanger bars, per Lutron document 048736.

  • Sivoia QS, extended hanger bars: 8.30 in (210.9 mm)
  • Alena: 3.00 in (76.0 mm) standard, 6.00 in (150.0 mm) extended
  • Extended hanger bars: custom request

The drive's close limit can be set for less overlap.

Where should the side channels of a blackout roller shade be fixed?

Lutron document 048736 aligns the side channels with the fabric drop. The drop moves toward the tube as the shade lowers and away from it as the shade rises.

The best position is found in a mock-up before fitting many rooms. Lutron warns that binding or buckling in the channels can telescope, pull out or damage the fabric.

What makes a roller shade fully blackout?

Lutron document 048736 combines a pocket or fascia mount, blackout fabric and three more parts.

  • Side channels: 2.5 in (63.5 mm), with black wool pile
  • Exposed hembar with black wool pile, and a sill angle
  • Pocket interior painted a dark non-reflective color

Side channels do not suit cable-guided, battery-powered or over-5° shades, nor make sheer fabric blackout.

Ask about 048736

Other Sivoia QS application notes

Application notes for the same Sivoia QS system:

All 17 Sivoia QS application notes

Documents used with 048736

Lutron document 048736 covers both Sivoia QS and Alena drapery tracks and points to the Sill Angle specification submittal. Lutron document 048843 covers the recessed drapery system, which 048736 ranks below a surface-mounted ceiling track for light blocking.

Revisions of 048736

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
CJul 2022Current. The file on assets.lutron.com. Checked 16 Oct 2026.

Not covered in 048736, and what to read next

Lutron document 048736 gives no wiring, limits, weights or installation steps; its overlap drawings are marked not for construction.

  • Shade: 086106 or 086105, the Roller 100 and 225 specification submittals
  • Track: 045982, the Sivoia QS drapery installation guide

Publisher and citation for document 048736

Lutron Electronics Co., Inc. publishes document 048736, Rev C, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 16 October 2026.

Lutron, Sivoia QS and Alena are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Sivoia QS?

New Way supplies and installs Lutron Sivoia QS shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.