Contact Us
Opens in a new tab

045616 · Installation Guide · Rev A · Apr 2018 · English, French, Spanish · PDF, 4 pages, 3.7 MB

Lutron Sivoia QS Roller Shades Installation Guide: Roller 20/64, Standard Single & Dual Mount Chassis (Universal Bracket) (045616, rev A)

Lutron's mounting guide for Roller 20 and Roller 64 shades on the single-mount universal bracket or the dual-mount bracket.

About document 045616

Lutron document 045616, Rev A of April 2018, is the standard single and dual mount chassis installation guide: bracket marking and fixing, cable entry, drive orientation, hanging and securing, in English, French and Spanish.

What guide 045616 covers

Lutron document 045616 has these eight sections. Each link opens the PDF at that page in a new tab.

  1. Prepare to install: Lutron items and tools, opens in a new tab page 1
  2. Mark the mounting bracket locations, opens in a new tab page 1
  3. Install the mounting brackets, opens in a new tab page 1
  4. Cable entry: single-mount and dual-mount, opens in a new tab page 1
  5. Orient the buttons and drive wires, opens in a new tab page 1
  6. Mount the shade, opens in a new tab page 1
  7. Secure and check the shade, opens in a new tab page 1
  8. Care and maintenance, opens in a new tab page 4

Specifications in 045616

Lutron document 045616 prints 18 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.

Ambient operating temperature
32 °F to 104 °F (0 °C to 40 °C)
Humidity
0 to 90%, non-condensing; indoor use only
Bracket-to-bracket distance
Tube width + 1.5 in (38 mm)
Idler compression at the correct distance
About 50% of its total travel
Single-mount universal bracket
2 screws per bracket
Dual-mount bracket
4 screws per bracket; one orientation only
Mounting surfaces
Wall, ceiling or jamb
Spacer blocks for a wall mount
May be needed to clear trim; not included
Supplied mounting screws
Self-drilling, for solid wood structural members
Cable exit side
Drive side of the system, from the wall, ceiling or jamb
Cable left exposed
12 to 18 in (30 to 45 cm)
Single-mount
Above or below the bracket, clear of the moving fabric
Dual-mount
A clearance hole on each of the bracket's 3 sides
Control button orientation
Downward or toward the room, with any bracket orientation
Ceiling or jamb orientation
Lower notch takes the retaining screw; wires through the front or rear notch
Wall orientation
Front notch takes the retaining screw; wires through the upper or lower notch
Supplied parts
Roller shade(s); single-mount bracket kit(s) with mounting brackets, mounting screws, bracket shims, and a cable tie and anchor; dual-mount bracket kit(s) with mounting brackets, mounting screws, and a cable tie and anchor
Tools required
Level, #2 Phillips screwdriver, 1/4 in (6 mm) hex-head driver, tape measure, power drill

Installation walk-through for 045616

Lutron document 045616 gives seven steps, in the document's order, after the tools and fixings it lists.

The clearance, the check and the warning under a step are the document's own.

Tools

  • Level
  • #2 Phillips screwdriver
  • 1/4 in (6 mm) hex-head driver
  • Tape measure
  • Power drill

Fixings

  • Self-drilling screws, supplied in both kits, for solid wood structural members
  • Fasteners suited to any other mounting surface (installer's choice)
  • Bracket shims (supplied in the single-mount bracket kit only)
  • Cable tie and anchor (supplied in both kits)
  • Spacer blocks for a wall mount, if needed (not included)
  1. Check the parts and tools

    Lay out the shade or shades and the bracket kits. The single-mount kit holds mounting brackets, mounting screws, bracket shims and a cable tie and anchor.

    The dual-mount kit holds the same without the shims. Depending on the quantities ordered, the kits may arrive inside the shade boxes or separately.

  2. Mark the bracket locations

    Mark the bracket positions level and centered over the window, where the screws reach a load-bearing structural member. Set the spacing from the bracket-to-bracket distance, never from the shade, whose idler spring compresses as it goes in.

    Leave room so the fabric cannot rub trim, the window or a top treatment.

    Clearance: Bracket-to-bracket distance = tube width + 1.5 in (38 mm)

    Check: At the correct distance the idler compresses about 50% of its travel

    Warning: A wall mount may need spacer blocks, not supplied, to clear the trim

  3. Install the mounting brackets

    Fix the brackets at the marks with fasteners that suit the surface. Use 2 screws in each single-mount universal bracket and 4 in each dual-mount bracket, which fits one way only.

    Check: Dual-mount brackets match the orientation Lutron draws in section 3

    Warning: The supplied self-drilling screws suit solid wood structural members; the installer chooses fasteners for any other surface

  4. Plan the cable entry

    Bring the cable out on the drive side. On a single mount, choose an entry above or below the bracket, clear of the bracket and the moving fabric.

    The dual-mount bracket offers a clearance hole on each of its three sides; use the bracket as a template.

    Clearance: 12 to 18 in (30 to 45 cm) of cable exposed

    Check: Cable entry and bracket position do not conflict

  5. Orient the buttons and drive wires

    Turn the control buttons to face down or toward the room, whichever stays easier to reach. The square yoke on the shade fits over the bracket tabs and has a notch on each side.

    In ceiling or jamb orientation the lower notch takes the retaining screw, the wires the front or rear notch. In wall orientation the front notch takes the retaining screw, the wires the upper or lower notch.

    Check: Wires sit in a notch the retaining screw does not use

  6. Mount the shade

    Fit the idler-end yoke over the tabs and behind the retaining screw head on the idler-end bracket. Press the shade toward the idler bracket to compress the spring-loaded idler.

    Then fit the drive-end yoke over its tab, behind the retaining screw head on the drive-end bracket. On a dual mount, repeat both moves for the second shade.

    Clearance: Idler compressed to 50% of its total travel

    Check: If the idler is not at 50% compression, take the shade down and adjust the brackets

  7. Secure and check the shade

    Tighten the retaining screw at each end of the shade, and on the second shade of a dual mount. Confirm the installed shades are level and centered on the window opening, and move a bracket if they are not.

    Check: Shade level and centered on the opening

Other warnings Lutron prints in 045616
  • Risk of falling objects: mount the system securely as instructed
  • Failing to follow the mounting instructions can cause minor to moderate injury
  • Use Lutron systems only with Lutron hardware, controls and power supplies
  • Install to all local and national electrical codes
  • Keep enough clearance between the moving shade and any object
  • Mount fixed controls and keep remote controls away from children
  • Do not run a shade that shows visible wear or damage

Requirements Lutron states in 045616

What the guide requires for a Sivoia QS shade before and during installation:

Operating environment
32 °F to 104 °F (0 °C to 40 °C), 0 to 90% humidity non-condensing, indoor use only
Bracket-to-bracket distance
Tube width plus 1.5 in (38 mm). At the correct distance the idler spring is compressed to about 50% of its travel
Screws per bracket
Single-mount universal bracket 2, dual-mount bracket 4
Dual-mount bracket orientation
Installs in one orientation only, as drawn in the bracket installation section
Cable left exposed
12 to 18 in (30 to 45 cm), exiting the wall, ceiling or jamb on the drive side of the system
Single-mount cable entry
Above or below the bracket, clear of the moving fabric and not in conflict with the bracket
Dual-mount cable entry
The dual-mount bracket has a clearance hole on each of its three sides. Exact hole dimensions are in the product specification submittal
Notches, ceiling or jamb
The lower notch takes the retaining screw, wires pass through the front or rear notch
Notches, wall orientation
The front notch takes the retaining screw, wires pass through the upper or lower notch
Trim clearance
Leave room so the fabric cannot rub trim, the window or a top treatment. A wall mount may need spacer blocks, not included
Supplied screws
Self-drilling mounting screws suited to solid wood structural members. The installer selects fasteners for any other surface
Bracket kit packing
Depending on the quantities ordered and shipped, the bracket kits may or may not be packed inside the shade boxes
Tools
Power drill, tape measure, level, 1/4 in (6 mm) hex-head driver and #2 Phillips screwdriver
Wiring and programming
Not in this guide. Lutron refers to Sivoia QS Basic Wiring and Setup, document 045520

Questions about document 045616

The answers come from Lutron document 045616 and New Way's record of it.

What is Lutron document 045616?

Lutron's four-page standard single and dual mount chassis guide for the Roller 20 and Roller 64, P/N 045616 Rev A. English sits on page 1, French on page 2, Spanish on page 3, the trilingual care note on page 4.

Which revision of 045616 is current?

Rev A, dated April 2018, is the revision Lutron publishes. New Way checked it against assets.lutron.com on 15 October 2026.

Which roller shades does 045616 cover?

Lutron Sivoia QS roller shades. For related steps Lutron refers readers to document 045520.

Does one guide cover both single and dual mounting?

Yes, Lutron document 045616 covers the single-mount universal bracket, which takes 2 screws, and the dual-mount bracket, which takes 4. The dual-mount bracket installs in one orientation only, and the second shade repeats the idler-end and drive-end steps.

Which fasteners does Lutron supply with the brackets?

Lutron document 045616 supplies self-drilling mounting screws that suit solid wood structural members. Lutron makes the installer responsible for fasteners on any other surface, sized for the operating load of the shade system.

What is the bracket-to-bracket distance?

Lutron document 045616 sets it at the tube width plus 1.5 in (38 mm). Measure from this distance, not the shade: the idler spring compresses to about 50% of its travel when spaced correctly.

Where does the drive cable enter?

Lutron document 045616 brings the cable out of the wall, ceiling or jamb on the drive side. Leave 12 to 18 in (30 to 45 cm) exposed.

A single mount takes the cable above or below the bracket. The dual-mount bracket has a clearance hole on each of its three sides.

Can the drive buttons face the room?

Yes, Lutron document 045616 lets the control buttons face downward or toward the room.

Choose whichever stays easier to reach once the shade and any top treatment are in. Either works with any bracket orientation and wire routing.

Ask about 045616

Other Sivoia QS installation guides

Installation guides for the same Sivoia QS system:

All 36 Sivoia QS installation guides

Documents used with 045616

Lutron document 045617 is the fascia mount chassis guide for the same Roller 20 and Roller 64 shades. Lutron document 045937 is the Roller 64 WIDR standard single and dual mount chassis installation guide.

Revisions of 045616

This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.

RevisionDateStatus
AApr 2018Current. The file on assets.lutron.com. Checked 15 Oct 2026.

Not covered in 045616, and what to read next

Lutron document 045616 leaves wiring and programming to another guide and prints no hole sizes for the dual-mount cable entry.

  • Wiring and programming: 045520, the Sivoia QS basic wiring and setup guide
  • Cable hole positions: 086112, the Roller 20 specification submittal

Publisher and citation for document 045616

Lutron Electronics Co., Inc. publishes document 045616, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 15 October 2026.

Lutron and Sivoia QS are trademarks of Lutron Electronics Co., Inc.

Reviewed by Edmond Hong, Technical Specialist, New Way.

Specifying Sivoia QS?

New Way supplies and installs Lutron Sivoia QS shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.

The form opens with document 045616 filled in.