Lutron 045616 Rev A (April 2018), Sivoia QS Roller Shades Installation Guide: Roller 20/64, Standard Single & Dual Mount Chassis (Universal Bracket). https://assets.lutron.com/a/documents/045616.pdf, via https://newwaykl.com/resources/lutron/roller-shades/sivoia-qs/lutron-sivoia-qs-roller-shades-installation-guide-045616/
About document 045616
Lutron document 045616, Rev A of April 2018, is the standard single and dual mount chassis installation guide: bracket marking and fixing, cable entry, drive orientation, hanging and securing, in English, French and Spanish.
What guide 045616 covers
Lutron document 045616 has these eight sections. Each link opens the PDF at that page in a new tab.
- Prepare to install: Lutron items and tools, opens in a new tab page 1
- Mark the mounting bracket locations, opens in a new tab page 1
- Install the mounting brackets, opens in a new tab page 1
- Cable entry: single-mount and dual-mount, opens in a new tab page 1
- Orient the buttons and drive wires, opens in a new tab page 1
- Mount the shade, opens in a new tab page 1
- Secure and check the shade, opens in a new tab page 1
- Care and maintenance, opens in a new tab page 4
Specifications in 045616
Lutron document 045616 prints 18 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.
Environment
PDF page 1 of 045616, opens in a new tab- Ambient operating temperature
- 32 °F to 104 °F (0 °C to 40 °C)
- Humidity
- 0 to 90%, non-condensing; indoor use only
Mounting brackets
PDF page 1 of 045616, opens in a new tab- Bracket-to-bracket distance
- Tube width + 1.5 in (38 mm)
- Idler compression at the correct distance
- About 50% of its total travel
- Single-mount universal bracket
- 2 screws per bracket
- Dual-mount bracket
- 4 screws per bracket; one orientation only
- Mounting surfaces
- Wall, ceiling or jamb
- Spacer blocks for a wall mount
- May be needed to clear trim; not included
- Supplied mounting screws
- Self-drilling, for solid wood structural members
Cable entry
PDF page 1 of 045616, opens in a new tab- Cable exit side
- Drive side of the system, from the wall, ceiling or jamb
- Cable left exposed
- 12 to 18 in (30 to 45 cm)
- Single-mount
- Above or below the bracket, clear of the moving fabric
- Dual-mount
- A clearance hole on each of the bracket's 3 sides
Buttons and drive wires
PDF page 1 of 045616, opens in a new tab- Control button orientation
- Downward or toward the room, with any bracket orientation
- Ceiling or jamb orientation
- Lower notch takes the retaining screw; wires through the front or rear notch
- Wall orientation
- Front notch takes the retaining screw; wires through the upper or lower notch
Lutron items
PDF page 1 of 045616, opens in a new tab- Supplied parts
- Roller shade(s); single-mount bracket kit(s) with mounting brackets, mounting screws, bracket shims, and a cable tie and anchor; dual-mount bracket kit(s) with mounting brackets, mounting screws, and a cable tie and anchor
- Tools required
- Level, #2 Phillips screwdriver, 1/4 in (6 mm) hex-head driver, tape measure, power drill
Installation walk-through for 045616
Lutron document 045616 gives seven steps, in the document's order, after the tools and fixings it lists.
The clearance, the check and the warning under a step are the document's own.
Tools
- Level
- #2 Phillips screwdriver
- 1/4 in (6 mm) hex-head driver
- Tape measure
- Power drill
Fixings
- Self-drilling screws, supplied in both kits, for solid wood structural members
- Fasteners suited to any other mounting surface (installer's choice)
- Bracket shims (supplied in the single-mount bracket kit only)
- Cable tie and anchor (supplied in both kits)
- Spacer blocks for a wall mount, if needed (not included)
Check the parts and tools
Lay out the shade or shades and the bracket kits. The single-mount kit holds mounting brackets, mounting screws, bracket shims and a cable tie and anchor.
The dual-mount kit holds the same without the shims. Depending on the quantities ordered, the kits may arrive inside the shade boxes or separately.
Mark the bracket locations
Mark the bracket positions level and centered over the window, where the screws reach a load-bearing structural member. Set the spacing from the bracket-to-bracket distance, never from the shade, whose idler spring compresses as it goes in.
Leave room so the fabric cannot rub trim, the window or a top treatment.
Clearance: Bracket-to-bracket distance = tube width + 1.5 in (38 mm)
Check: At the correct distance the idler compresses about 50% of its travel
Warning: A wall mount may need spacer blocks, not supplied, to clear the trim
Install the mounting brackets
Fix the brackets at the marks with fasteners that suit the surface. Use 2 screws in each single-mount universal bracket and 4 in each dual-mount bracket, which fits one way only.
Check: Dual-mount brackets match the orientation Lutron draws in section 3
Warning: The supplied self-drilling screws suit solid wood structural members; the installer chooses fasteners for any other surface
Plan the cable entry
Bring the cable out on the drive side. On a single mount, choose an entry above or below the bracket, clear of the bracket and the moving fabric.
The dual-mount bracket offers a clearance hole on each of its three sides; use the bracket as a template.
Clearance: 12 to 18 in (30 to 45 cm) of cable exposed
Check: Cable entry and bracket position do not conflict
Orient the buttons and drive wires
Turn the control buttons to face down or toward the room, whichever stays easier to reach. The square yoke on the shade fits over the bracket tabs and has a notch on each side.
In ceiling or jamb orientation the lower notch takes the retaining screw, the wires the front or rear notch. In wall orientation the front notch takes the retaining screw, the wires the upper or lower notch.
Check: Wires sit in a notch the retaining screw does not use
Mount the shade
Fit the idler-end yoke over the tabs and behind the retaining screw head on the idler-end bracket. Press the shade toward the idler bracket to compress the spring-loaded idler.
Then fit the drive-end yoke over its tab, behind the retaining screw head on the drive-end bracket. On a dual mount, repeat both moves for the second shade.
Clearance: Idler compressed to 50% of its total travel
Check: If the idler is not at 50% compression, take the shade down and adjust the brackets
Secure and check the shade
Tighten the retaining screw at each end of the shade, and on the second shade of a dual mount. Confirm the installed shades are level and centered on the window opening, and move a bracket if they are not.
Check: Shade level and centered on the opening
Requirements Lutron states in 045616
What the guide requires for a Sivoia QS shade before and during installation:
- Operating environment
- 32 °F to 104 °F (0 °C to 40 °C), 0 to 90% humidity non-condensing, indoor use only
- Bracket-to-bracket distance
- Tube width plus 1.5 in (38 mm). At the correct distance the idler spring is compressed to about 50% of its travel
- Screws per bracket
- Single-mount universal bracket 2, dual-mount bracket 4
- Dual-mount bracket orientation
- Installs in one orientation only, as drawn in the bracket installation section
- Cable left exposed
- 12 to 18 in (30 to 45 cm), exiting the wall, ceiling or jamb on the drive side of the system
- Single-mount cable entry
- Above or below the bracket, clear of the moving fabric and not in conflict with the bracket
- Dual-mount cable entry
- The dual-mount bracket has a clearance hole on each of its three sides. Exact hole dimensions are in the product specification submittal
- Notches, ceiling or jamb
- The lower notch takes the retaining screw, wires pass through the front or rear notch
- Notches, wall orientation
- The front notch takes the retaining screw, wires pass through the upper or lower notch
- Trim clearance
- Leave room so the fabric cannot rub trim, the window or a top treatment. A wall mount may need spacer blocks, not included
- Supplied screws
- Self-drilling mounting screws suited to solid wood structural members. The installer selects fasteners for any other surface
- Bracket kit packing
- Depending on the quantities ordered and shipped, the bracket kits may or may not be packed inside the shade boxes
- Tools
- Power drill, tape measure, level, 1/4 in (6 mm) hex-head driver and #2 Phillips screwdriver
- Wiring and programming
- Not in this guide. Lutron refers to Sivoia QS Basic Wiring and Setup, document 045520
Questions about document 045616
The answers come from Lutron document 045616 and New Way's record of it.
What is Lutron document 045616?
Lutron's four-page standard single and dual mount chassis guide for the Roller 20 and Roller 64, P/N 045616 Rev A. English sits on page 1, French on page 2, Spanish on page 3, the trilingual care note on page 4.
Which revision of 045616 is current?
Rev A, dated April 2018, is the revision Lutron publishes. New Way checked it against assets.lutron.com on 15 October 2026.
Which roller shades does 045616 cover?
Lutron Sivoia QS roller shades. For related steps Lutron refers readers to document 045520.
Does one guide cover both single and dual mounting?
Yes, Lutron document 045616 covers the single-mount universal bracket, which takes 2 screws, and the dual-mount bracket, which takes 4. The dual-mount bracket installs in one orientation only, and the second shade repeats the idler-end and drive-end steps.
Which fasteners does Lutron supply with the brackets?
Lutron document 045616 supplies self-drilling mounting screws that suit solid wood structural members. Lutron makes the installer responsible for fasteners on any other surface, sized for the operating load of the shade system.
What is the bracket-to-bracket distance?
Lutron document 045616 sets it at the tube width plus 1.5 in (38 mm). Measure from this distance, not the shade: the idler spring compresses to about 50% of its travel when spaced correctly.
Where does the drive cable enter?
Lutron document 045616 brings the cable out of the wall, ceiling or jamb on the drive side. Leave 12 to 18 in (30 to 45 cm) exposed.
A single mount takes the cable above or below the bracket. The dual-mount bracket has a clearance hole on each of its three sides.
Can the drive buttons face the room?
Yes, Lutron document 045616 lets the control buttons face downward or toward the room.
Choose whichever stays easier to reach once the shade and any top treatment are in. Either works with any bracket orientation and wire routing.
Other Sivoia QS installation guides
Installation guides for the same Sivoia QS system:
| Document | Drive class | Revision | Date |
|---|---|---|---|
| 045617Roller Shades Installation Guide: Roller 20/64, Fascia Mount Chassis | Roller 20, Roller 64 | A | Apr 2018 |
| 045937Roller 64 Installation Guide: WIDR, Standard Single & Dual Mount Chassis (Universal Bracket) | Roller 64 | A | Aug 2023 |
| 045618ROLLER 20/64 – Pocket Mount Chassis Installation Guide | Roller 20, Roller 64 | A | May 2018 |
| 045000710 Output Power Panel Power Supply (12 V) Installation Guide | Roller 20 to 300 | A | Jul 2025 |
Documents used with 045616
Lutron document 045617 is the fascia mount chassis guide for the same Roller 20 and Roller 64 shades. Lutron document 045937 is the Roller 64 WIDR standard single and dual mount chassis installation guide.
| Document | Type | Revision | Date |
|---|---|---|---|
| 045520Basic Wiring and Setup Installation Guide | Installation Guide | B | Nov 2016 |
| 0853144-Group RF Remote Control Specification Submittal | Specification Submittal | C | May 2016 |
| 369847Pico Wireless Control, 4-Button Specification Submittal | Specification Submittal | K | Mar 2024 |
| CAD Drawing: Shade Equipment CAD Block | CAD Drawing | ||
| 085612Roller 100 CAD Drawing: 4.75″ x 5″ (121 x 127mm) Pocket, Detail Drawing | CAD Drawing | A | |
| 085274Hard Wired Power Supply Specification Submittal | Specification Submittal | D | Aug 2014 |
| Roller Shades Revit Family: QS Shading Keypad 3-Group 3-Button with Raise/Lower | Revit Family | ||
| 048846Application Note: EU EcoDesign Standby Power Information | Application Note | A | Nov 2024 |
| 048863Roller Shades Application Note: Fabric Aesthetic Characteristics | Application Note | A | May 2026 |
| 08533510-Output Smart Panel Specification Submittal | Specification Submittal | D | Apr 2020 |
Revisions of 045616
This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.
| Revision | Date | Status |
|---|---|---|
| A | Apr 2018 | Current. The file on assets.lutron.com. Checked 15 Oct 2026. |
Not covered in 045616, and what to read next
Lutron document 045616 leaves wiring and programming to another guide and prints no hole sizes for the dual-mount cable entry.
Publisher and citation for document 045616
Lutron Electronics Co., Inc. publishes document 045616, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 15 October 2026.
Lutron and Sivoia QS are trademarks of Lutron Electronics Co., Inc.
Reviewed by Edmond Hong, Technical Specialist, New Way.
Specifying Sivoia QS?
New Way supplies and installs Lutron Sivoia QS shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.
The form opens with document 045616 filled in.