You searched and this document matched it.
See all results085675 · CAD Drawing · Rev A · English · PDF, DWG, DXF
Lutron Sivoia QS Roller 64 CAD Drawing: WIDR Corner Staggered Regular Roll (085675)
Lutron's CAD drawing of the Roller 64 WIDR staggered roll installation, where two shades meet at a corner.
Lutron 085675 Rev A, Sivoia QS Roller 64 CAD Drawing: WIDR Corner Staggered Regular Roll. https://assets.lutron.com/a/documents/085675_roller_64_widr_corner_staggered_regular_roll.pdf, via https://newwaykl.com/resources/lutron/roller-shades/sivoia-qs/lutron-sivoia-qs-roller-64-cad-drawing-085675/
About document 085675
Lutron drawing 085675, Rev A, is the two-page staggered roll corner drawing: typical details, light gap and clearances on page 1, bracket details, roll-up and measurement deductions on page 2, as PDF, DWG and DXF.
What drawing 085675 covers
Lutron document 085675 has these seven sections. Each link opens the PDF at that page in a new tab.
- Staggered roll typical details, wall bracket shown, opens in a new tab page 1
- Regular roll light gap and minimum clearances, opens in a new tab page 1
- Clearance note and adjustment features, opens in a new tab page 1
- Top views of the staggered roll bracket details, opens in a new tab page 2
- Maximum and minimum roll-up, opens in a new tab page 2
- Measurement deductions for the 90 degree corner, opens in a new tab page 2
- Title blocks with scale, page number and revision, opens in a new tab page 1
Specifications in 085675
Lutron document 085675 prints 15 values in the groups the document uses, each with the document's unit. The page link beside each group opens the PDF where the group starts.
Typical details
PDF page 1 of 085675, opens in a new tab- Bracket shown
- Wall bracket
- System height and mounting
- Refer to the section drawing
Auxiliary views
PDF page 1 of 085675, opens in a new tab- Regular roll light gap at maximum roll
- 1.645 in (42 mm)
- Minimum clearance required, two callouts
- 0.25 in (6 mm)
- Scale noted beside one view (sheet scale 1/5)
- 1/6
- Label
- Wall
- Maximum roll-up
- 3.30 in (84 mm)
- Minimum roll-up
- 2.00 in (51 mm)
- Measurement deduction
- 1.21 in (31 mm)
- Measurement deduction
- 0.20 in (5 mm)
- Deduction basis
- Minimum recommended deductions, 90 degree corner, applied to both shades
Scale, page, revision
PDF pages 1 and 2 of 085675, opens in a new tab- Page 1 scale
- 1/5
- Page 2 scale
- 1/4
- Revision
- A, on both pages
- Pages
- 2
Facts Lutron states in 085675
The values Lutron document 085675 states, as published:
- Shade covered
- Two Roller 64 WIDR shades in a staggered roll corner installation, wall bracket shown
- Light gap, regular roll
- 1.645 in (42 mm) at maximum roll
- Minimum clearance required
- 0.25 in (6 mm), printed twice on the auxiliary views
- Maximum roll-up
- 3.30 in (84 mm)
- Minimum roll-up
- 2.00 in (51 mm)
- Measurement deductions
- 1.21 in (31 mm) and 0.20 in (5 mm)
- Deduction basis
- Minimum recommended deductions, based on a 90 degree corner and applied to both shades
- Top view label
- The page 2 sheet, titled top views, shows one plan view labeled wall
- Scale, page and revision
- Page 1, auxiliary views, at 1/5, one view noted at 1/6
- Page 2, top views, at 1/4
- Revision A on both pages, no date printed
- System height and mounting
- Not on this drawing, which refers the reader to the section drawing
- Clearances as supplied
- A shade installed as supplied by the factory has the clearances it needs
- Adjustment features
- Lutron makes the installer responsible for keeping proper clearances once adjustment features are used
- Adjustment at maximum roll
- Not all adjustments are available at the maximum roll diameter
- File formats
- PDF, DWG and DXF
Questions about document 085675
The answers come from Lutron document 085675 and New Way's record of it.
What is Lutron document 085675?
Lutron's CAD drawing of the Roller 64 WIDR staggered roll installation, where two shades meet at a corner. Lutron drawing 085675, Rev A, is the two-page staggered roll corner drawing: typical details, light gap and clearances on page 1, bracket details, roll-up and measurement deductions on page 2, as PDF, DWG and DXF.
Which revision of 085675 is current?
Rev A is the revision Lutron publishes. New Way checked it against assets.lutron.com on 16 October 2026.
Which roller shades does 085675 cover?
Lutron Sivoia QS roller shades in the Roller 64 drive class.
What light gap does Lutron show at the staggered corner?
Lutron drawing 085675 prints a regular roll light gap of 1.645 in (42 mm) at maximum roll on the auxiliary views of page 1.
What deductions apply when ordering the two shades?
Lutron prints measurement deductions of 1.21 in (31 mm) and 0.20 in (5 mm) on the top views of page 2. Lutron calls them minimum recommended deductions, based on a 90 degree corner and applied to both shades.
What minimum clearance does the drawing require?
Lutron drawing 085675 prints a minimum clearance of 0.25 in (6 mm) at two places on the page 1 auxiliary views. Lutron labels both only as minimum clearance required.
Can the installer use the adjustment features at the corner?
Lutron states that a shade installed as supplied by the factory already has the clearances it needs for proper operation. Once the adjustment features are used, Lutron makes the installer responsible for keeping proper clearances.
Lutron warns that not all adjustments are available at the maximum roll diameter.
How large is the roll-up at the corner?
Lutron drawing 085675 prints a maximum roll-up of 3.30 in (84 mm) and a minimum roll-up of 2.00 in (51 mm) on page 2.
Other Sivoia QS Roller 64 CAD drawings
CAD drawings for the same Sivoia QS Roller 64 drive class:
| Document | Drive class | Revision | Date |
|---|---|---|---|
| 085674Roller 64 CAD Drawing: WIDR Corner to Corner Regular Roll | Roller 64 | A | |
| 085673Roller 64 CAD Drawing: WIDR Butt and Pass Corner Solution | Roller 64 | A | |
| 085778Roller 64 CAD Drawing: WIDR Dual Shade Bracket, Detail Drawing | Roller 64 | A | |
| 085672Roller 64 CAD Drawing: WIDR Shade Bracket, Detail Drawing | Roller 64 | A |
Documents used with 085675
Lutron's other Roller 64 WIDR corner drawings are 085674 (corner to corner) and 085673 (butt and pass). Lutron's WIDR bracket details are 085672 (universal) and 085778 (dual), and 085705 is the Roller 64 specification submittal.
| Document | Type | Revision | Date |
|---|---|---|---|
| 085705Roller 64 Specification Submittal | Specification Submittal | D | Sep 2025 |
| 045843Roller 64 Installation Guide: WIDR Pocket Mount | Installation Guide | B | Sep 2021 |
| 045929Roller 64 Installation Guide: WIDR, 4″ Fascia Mount Chassis (Regular Roll) | Installation Guide | B | Aug 2023 |
| Roller 64 Revit Family: Ceiling Mount | Revit Family | ||
| Roller 64 Revit Family: Dual (Ceiling Mount) | Revit Family | ||
| Roller 64 Revit Family: Dual (Wall Mount) | Revit Family | ||
| Roller 64 Revit Family: Pocket Mount | Revit Family | ||
| Roller 64 Revit Family: Wall Mount | Revit Family | ||
| 0853144-Group RF Remote Control Specification Submittal | Specification Submittal | C | May 2016 |
| 369847Pico Wireless Control, 4-Button Specification Submittal | Specification Submittal | K | Mar 2024 |
Revisions of 085675
This page always shows the revision Lutron publishes today. Lutron replaces the file in place and does not keep earlier revisions online.
| Revision | Date | Status |
|---|---|---|
| A | Not stated | Current. The file on assets.lutron.com. Checked 16 Oct 2026. |
Not covered in 085675, and what to read next
Lutron drawing 085675 gives no system height, bracket dimensions or mounting fixings, and points to the section drawing for them.
Publisher and citation for document 085675
Lutron Electronics Co., Inc. publishes document 085675, Rev A, and serves it from assets.lutron.com. New Way hosts no copy and last checked the file there on 16 October 2026.
Lutron and Sivoia QS are trademarks of Lutron Electronics Co., Inc.
Reviewed by Edmond Hong, Technical Specialist, New Way.
Specifying Sivoia QS?
New Way supplies and installs Lutron Sivoia QS shading in Malaysia and Singapore. A New Way specifier can check your shade schedule and drawings before you submit.
The form opens with document 085675 filled in.